University of Ioannina
Συγκριτική μελέτη αποτελεσμάτων ολικής αρθροπλαστικής γόνατος χειρουργημένης με συμβατικές μεθόδους και με συστήματα πλοήγησης
Abstract
dc:descriptionBackground: Knee osteoarthritis is the most common joint disorder of the adult population. The last stage of the disease is usually treated with total knee arthroplasty, which, given its irreversible nature, is recommended only when the rest of treatments have failed. The functional effect and the implant survival depend on factors like the axial alignment of the joint and the leg and the correct orientation of the implant charging surfaces. Computer-assisted navigation systems have been developed to minimal bone loss in combination with the more accurate placement of the implants and aiming an optimum operating result, the longer life and the prevention of the implant abruption. However, the published results are conflicting about the beneficial operational results of Computer-assisted navigation systems. On this basis, the present randomized study investigates the implant placement, the axial alignment of the leg and the ligament balancing both after conventional and computer-assisted navigated total knee replacement.Methods: For this purpose, 37 patients underwent total knee arthroplasty with a navigation system (Navigator group) and 22 with the conventional method. The average age was 67.32 ± 12.63 years in the Navigator group and 68.24 ± 6.48 years in the conventional group. The process of electronic navigation took place using Orthopilot by Aesculap and Columbus knee implant, while the second group included knee replacements performed only with conventional tools (conventional implants Advance by Wright in 10 patients, NexGen by Zimmer in a patient and First by Zimmer in 11 patients). The surgical technique performed in total knee replacement surgery was the same for both groups. The statistical processing of data and the presentation of results were made with the statistical software package SPSS (version 21.0).Results: Results showed that the operative time for the Navigator group was statistically significantly greater than the operative time of the conventional group. On the other hand, overall, there were no significant differences in the clinical outcomes of both techniques. Specifically, the differences between hematocrit and hemoglobin values of the two groups were not statistically significant and the number of vials transfused in the Navigator group per time was the same as in the conventional group. Also, the tibial varus angle and the anatomical - mechanical axis angle, both preoperatively and postoperatively, the values of intramedullary inclination, the range of motion and the values of preoperative and postoperative knee outcome survey score, were not found to differ statistically between the two groups.Conclusions: These results, combined with the high cost of the navigation systems, discourage the adoption of this technique for total knee arthroplasty by modern surgeons. Perhaps, the development of more sensitive evaluation systems might be able to highlight the advantages of the computer-assisted navigation systems that are not visible with the use of the current evaluation methods.
Degree
thesis:*- Grantor dc:publisher
- University of Ioannina
- Year dc:date
- 2016
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Mitsiou, Diamantis
- Μήτσιου, Διαμαντής
Subjects
dc:subject × 14Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/43880