Seismic performance assessment of industrial facility atmospheric liquid storage tanks

Abstract

dc:description

Large-capacity atmospheric tanks are widely used to store a variety of liquid-form materials that are deemed necessary for the functionality of any modern community. The devastating consequences of earthquake damage on liquid storage tanks (e.g. Kocaeli 1999, Tohoku 2011) have revealed the vulnerability of such structural systems against strong ground motions, while at the same time have highlighted the need for innovative engineering concepts in order to mitigate the associated socioeconomic losses. Along these lines, the seismic performance of industrial-facility atmospheric liquid storage tanks is examined, in view of providing an easy-to-implement assessment tool that offers reliable results within a reasonable timeframe with respect to structural analysis and the associated post-processing.Following the concepts of performance-based earthquake engineering, a three-dimensional reduced-order (i.e. surrogate) model is formed to obtain the distribution of the various engineering demand parameters of interest under earthquake loading. Liberated from the need for structure-specific calibration using detailed finite element models, the proposed model is able to represent both anchored and unanchored liquid storage tanks, using ground motion components at multiple principal loading directions simultaneously. Exploiting the virtues of the model in our disposal allows to summarise a considerable volume of analysis results in the form of the fragility curves and perform the subsequent integration with the site hazard of interest to derive the associated mean annual frequency of exceeding certain failure mode thresholds. In view of a comprehensive seismic risk assessment estimation, both component and system-level damage states are employed. Commonly observed modes of failure such as base plate plastic rotation, elephant’s foot buckling, sloshing-wave-induced damage and anchorage failure, are used to form the component-level damage classification. Special attention is paid to the elephant’s foot buckling failure mode, as the underlying criterion to signal failure is time and seismic intensity dependent. The aforementioned failure modes are appropriately combined to form the system-level damage classification and thus obtain information for a group of tanks rather than a structural system alone. Several scalar and vector seismic intensity measures are also examined in order to come up with a solution that on one hand minimises the required number of records to achieve numerical fidelity, and on the other renders structural response independent of ground motion characteristics. The geometric mean of spectral accelerations in the range of 0.1s and 4.5 times the fundamental period of vibration is proposed as a potentially optimal solution to perform the seismic risk assessment estimation. The latter is employed to perform a seismic vulnerability assessment on an indicative tank farm layout, whereby suitable damage indices are defined to estimate the expected loss of stored material and storage capacity following a strong ground motion.

Degree

thesis:*
Grantor dc:publisher
National Technical University of Athens (NTUA)
Year dc:date
2018

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Bakalis, Konstantinos
  • Μπακάλης, Κωνσταντίνος

Subjects

dc:subject × 18

Rights

Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/44000

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Bakalis, Konstantinos; Μπακάλης, Κωνσταντίνος. Seismic performance assessment of industrial facility atmospheric liquid storage tanks. National Technical University of Athens (NTUA), 2018. http://hdl.handle.net/10442/hedi/44000