Η επίδραση της υποβοήθησης με παραορτική αντλία αντιώθησης (PULVAD) στους δείκτες συστολικής και διαστολικής λειτουργίας της αριστεράς κοιλίας σε χοίρειο μοντέλο οξείας καρδιακής ανεπάρκειας

Abstract

dc:description

Introduction: We have developed the Pressure Unloading Left Ventricular Assist Device (PULVAD), a novel implantable counterpulsation device, designed to provide left ventricular (LV) pressure unloading with augmentation of LV performance and retention of pulsatility. We assessed the effects of PULVAD on hemodynamics, LV mechanoenergetics and myocardial perfusion in a porcine model of acute heart failure. Methods: PULVAD comprises a pneumatically-driven pumping chamber implanted in the thoracic cavity and connected to the ascending aorta. PULVAD is ECG-synchronized and operates under the counterpulsation principle: deflation of the device air chamber just prior and during systole draws blood from the aorta into the device blood chamber, while inflation of the device air chamber during diastole ejects blood from the device blood chamber into the aorta. Seven farm pigs (80-90 kg) were instrumented with Millar catheter, sonomicrometry crystals and a Doppler flow probe placed around the left anterior descending artery (LAD). Pigs underwent PULVAD implantation and induction of acute heart failure by LAD ligation for 60 minutes, followed by reperfusion. PULVAD was driven by a standard intra-aortic balloon pump console. Hemodynamics and indices of LV mechanoenergetics were measured without and after brief (<60 secs) PULVAD support during reperfusion. Results: PULVAD support induced a profound reduction of LV afterload (systolic aortic pressure decreased by 19.2 mmHg and end-diastolic aortic pressure decreased by 22.3 mmHg). PULVAD support improved the mechanical performance of the failing LV (increased ejection fraction by 4.2%, cardiac output by 7% and stroke volume by 16%) as well as the systolic function (increased maximum elastance by 50%). The PULVAD concurrently decreased LV energy consumption (stroke work decreased by 16% and pressure volume area decreased by 25%) and optimized LV energetic performance (improved the ratio of stroke work to pressure volume area from 52.8% to 59.0%). Conclusions: The PULVAD unloads the failing LV and optimizes LV mechanoenergetics, by decreasing LV energy consumption, while concomitantly improves LV mechanical perfoermance and efficiency. These salutary effects of short-term PULVAD support provide the foundation for long-term testing.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2018

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Kontogiannis, Christos
  • Κοντογιάννης, Χρήστος

Subjects

dc:subject × 6

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/44036

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Kontogiannis, Christos; Κοντογιάννης, Χρήστος. Η επίδραση της υποβοήθησης με παραορτική αντλία αντιώθησης (PULVAD) στους δείκτες συστολικής και διαστολικής λειτουργίας της αριστεράς κοιλίας σε χοίρειο μοντέλο οξείας καρδιακής ανεπάρκειας. National and Kapodistrian University of Athens, 2018. http://hdl.handle.net/10442/hedi/44036