Back to search

Democritus University of Thrace (DUTH)

Αποκατάσταση και ενίσχυση διαβρωμένων στοιχείων από ωπλισμένο σκυρόδεμα με σύνθετα υλικά

Abstract

dc:description

This study reviews thoroughly available experiments and analytical approaches in the relevant international literature and introduces a calculation model for assessing steel bar mass loss and contributes to further utilization of common in-situ inspections from a structural point of view. The model is based on the width of longitudinal crack of concrete cover, as a function of cover depth, bar diameter and mechanical properties of concrete. The model includes the well-known relationships for the steel mass loss during the first phase of rust formulation, filling the porous zone as well as during the phase that the radial pressure exceeds the concrete strength and causes cover cracking. The assumption followed herein for the flexibility of cracked concrete allows for the estimation of steel bar corrosion rate even beyond concrete cover cracking, by visual mapping of the width of longitudinal cracks. Then, the corresponding flexural capacity of the beams at yield and at maximum may be assessed. The predictions of the model are validated against 51 non-strengthened corroded beams and 24 strengthened corroded beams with FRP materials published in the international literature.The experimental results on the effectiveness of patch repair and Fiber Reinforced Polymers bonded laminates to retrofit reinforced concrete beams with corrosion damage are investigated in the present research. The uncovering of the damaged concrete cover provides a more accurate assessment of the corrosion degree, as the actual mass loss of reinforcement can be better calibrated. The mass loss of the tensile reinforcement varied at approximately 7.5% to 24%. The necessity of the removal of the cracked concrete substrate, treatment of corroded reinforcement and repair by patching with a polymer modified mortar is highlighted. Two different strengthening techniques are implemented, of externally bonded EBR or NSM Carbon Fiber Reinforced Polymers, having equivalent axial rigidity. CFRP wraps were also applied for shear strengthening to replace corroded stirrups. The load-deflection curves showed that the effect of corrosion on load bearing capacity and bond between the concrete and steel was detrimental for high mass losses. Α satisfactory force transfer through the old and patch repaired concrete and through repair mortar and CFRP reinforcement interface was noted. The shear strengthening not only prevented the debonding of the EB laminate at the end but also improved the bond performance between the laminate and concrete, especially for the high corroded beam.In the current research the structural behavior of reinforced concrete beams with corroded steel reinforcement at service loads was also studied. One beam was non-corroded, while two beams were corroded under the same conditions of an accelerated electrochemical technique and then subjected to vertical service loads that corresponded to 60% and 75% of the yield load of the non-corroded beam respectively for three corrosion cycles (with maximum mass loss around 25% for the first and 30% for the latter). Longitudinal cracks due to corrosion and flexural cracks due to loading were thoroughly recorded at the end of each cycle. The beam under the 75% service load had higher deflection increase for heavier corrosion. After the three successive serviceability load tests, the cracked concrete cover was removed and the steel rebars were treated. The cement-based repair mortar and two NSM FRP laminates were applied to both beams and were tested to failure. Despite the heavy corrosion, the patch repair and NSM strengthening enhanced the load-bearing capacity of the beams when compared with the non-corroded beam.Three-dimensional Finite Element (FE) models for the corroded reinforced concrete beams were developed and validated against the consequent experimental study. Experimental and 3D numerical modeling results are presented in terms of load-deflection curves and failure modes for corroded RC beams at three different corrosion levels (low, medium, high), patch repaired with polymer modified mortar and strengthened with externally bonded EBR or near surface mounted NSM CFRP laminates. The 3D FE models take into account the different mechanical properties and detailing of corroded bars and of the mortar patch as well as of the existing concrete – mortar patch interface and of the NSM or EBR FRP – mortar patch interface. The high reliability of the FE models allowed for extensive parametric studies to assess the influence of the mechanical properties of the old concrete and of the repair mortar on the performance of retrofits with multiple critical interfaces, the modes of failure and the behavior of the strengthened beams.

Degree

thesis:*
Grantor dc:publisher
Democritus University of Thrace (DUTH)
Year dc:date
2018

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Triantafyllou, Garyfalia
  • Τριανταφύλλου, Γαρυφαλιά

Subjects

dc:subject × 24

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/44151

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Triantafyllou, Garyfalia; Τριανταφύλλου, Γαρυφαλιά. Αποκατάσταση και ενίσχυση διαβρωμένων στοιχείων από ωπλισμένο σκυρόδεμα με σύνθετα υλικά. Democritus University of Thrace (DUTH), 2018. http://hdl.handle.net/10442/hedi/44151