University of the Aegean
Μελέτη της απομάκρυνσης με προσρόφηση από ενεργό άνθρακα των οργανικών παραπροϊόντων της χλωρίωσης του πόσιμου νερού
Abstract
dc:descriptionThe objective of the present work is to study the removal of the two main groups of chlorination by-products, trihalomethanes (THMs) and haloacetic acids (HAAs), as well as of dissolved organic matter (DOC) from drinking water by a granular activated carbon (GAC) filter-adsorber and postfilter-adsorber under real conditions. More specifically, the objective of this work is to determine and evaluate the performance of granular activated carbon as a filter-adsorber medium (GAC(A) and a postfilter-adsorber medium (GAC(B)) for the removal from Athens drinking water of THMs and HAAs, as well as of DOC, under real conditions. It is also to compare the efficiency of the two methods and to predict their performance in case of application in Galatsi water treatment plant (GWTP). The long term objective is to evaluate the usefulness of application of GAC adsorption process in Athens drinking water treatment. THMs and HAAs in drinking water have been proved dangerous for human health and have been regulated in many countries. In addition, the removal of natural organic compounds (DOC), which are their precursors is necessary. According to the international research experience, THMs, HAAs and a part of DOC are adsorbable by GAC, while HAAs and a part of DOC are biodegradable. The experimental work was carried out on a pilot scale, since it can only provide the best approximation to the real efficiency of a GAC adsorber. Two series of experiments were carried out with the water in Galatsi WTP, Athens. The choice of the two GAC types was based on international experience, so that the pilot research is more practically useful. In both series, the GAC pilot plant operated as a rapid gravity filter. The GAC bed depth was the same, while the mean carbon grain size and the water flow rate were lower for the postfilter-adsorber. The empty bed contact time was 9.5 min for the filter-adsorber and 14 min for the postfilter-adsorber. The GAC filter- adsorber operated in parallel with a full-scale sand filter. During the operation of the pilot plant at regular time intervals water samples were taken from the inlet, outlet and different depths of the GAC filter and from the inlet and outlet of the parallel operating sand filter in the A series. The parameters measured were: THMs, HAAs, DOC, free residual chlorine, bromide, turbidity, solUV-absorption at 254 nm, pH, temperature, as well as microbiological parameters (total coliforms, E-coli, enterococci, heterotrophic bacteria) for a period of A series. The operation of both GAC filters was stopped when the removal of the above groups of compounds was significantly reduced. The net operation time of the GAC pilot filter-adsorber was 235 days (156 filter runs) and for the postfilter-adsorber 638 days (105 filter runs). The GAC as a filter-adsorber and a postfilter-adsorber medium removed from water THMs, HAAs and DOC to a satisfactory degree for a practically useful period of time. The GAC breakthrough capacity for DOC was proved quite higher than that for the other groups of compounds, lower for total -HAAs (THAAs) and even lower for total-THMs (TTHMs). The higher GAC efficiency for the removal of DOC in comparison with that for the smaller molecules of THMs and HAAs (with a two-rank higher concentration of DOC) was in accordance with the relative literature. The removal of THMs and the most part of the removal of HAAs and DOC should be attributed to adsorption by GAC, while that of a smaller part of HAAs and DOC may be attributed to biodegradation in the filter bed, where dechlorination favours microbial growth, as was noticed. The higher removal of DOC than HAAs and THMs and the higher removal of HAAs than THMs are attributed to better adsorption and possibly biodegradation. The GAC postfilter-adsorber was proved to be more effective in the removal of TTHMs, THAAs and DOC than the GAC filter-adsorber. This fact is attributed to the characteristics of GAC(B) and the postfilter-adsorber operation, which favour adsorption and biodegradation, as well as to the higher influent concentrations of all groups to GAC(B). Desorption incidents, especially of volatile and weakly adsorbing THMs, as well as of HAAs, were observed more frequently during the postfilter-adsorber operation, mainly near the breakthrough or saturation points. Continuous monitoring of the concentration of individual THMs and HAAs species and also of DOC in effluent water and interruption of the operation of the GAC filter in due time is necessary to avoid desorption. The UV-absorption of filtered water at 254 nm (SOL-UV(254)-A) was proved to be a useful substitute parameter for the DOC content of water and can be used as an operational control parameter. In addition, the GAC filter-adsorber removed turbidity from water better than the sand filter and was almost equally effective as the sand filter for the removal of microorganisms of sanitary significance. The presence of a large number of heterotrophic bacteria in GAC effluent water confirmed the phenomenon of biodegradation of organics in the GAC bed. Sufficient postchlorination of GAC effluent water is necessary for the protection of public health, as well as additional sand filtration of GAC effluent water or other system for the retention of carbon fines. For the comparison of the adsorption efficiency of the GAC filter-adsorber and postfilter-adsorber, theoretical analysis of experimental results with the use of the Freundlich isotherm was applied, in which the impact of the difference between the feed concentrations of TTHMs, THAAs and DOC to the two GAC-adsorbers was subtracted. Under the hypothesis of equal influent concentrations to both GAC adsorbers, it was theoretically predicted that the GAC postfilter-adsorber in Galatsi WTP is expected to give much higher capacity, longer operation times and higher volumes of processed water until saturation for TTHMs, THAAs and especially DOC. Technicoeconomical analysis showed that the additional operational cost of the production of the drinking water in GWTP was low for both operations. The predicted operational cost of the GAC postfilter-adsorber was 60 % lower than that of the GAC filter-adsorber. Also, in both cases, GAC thermal reactivation was found to be half costly than rejection after use.
Degree
thesis:*- Grantor dc:publisher
- University of the Aegean
- Year dc:date
- 2008
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Babi, Konstantina
- Μπαμπή, Κωνσταντίνα
Subjects
dc:subject × 8Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/44657