National and Kapodistrian University of Athens
Μη επεμβατική 24ωρη καταγραφή αορτικής πίεσης: συσχέτιση με τη βλάβη οργάνων-στόχου
Abstract
dc:descriptionIntroduction – aim: Evidence suggests the superiority of office aortic pressure compared to brachial pressure on the evaluation of – the blood pressure (BP) associated - cardiovascular damage and prognosis of cardiovascular disease (CVD); 24-hour ambulatory blood pressure monitoring (ABPM) is regarded as the optimal method for assessing BP profile. The non-invasive assessment of 24 hour aortic BP, as well as indices of aortic stiffness (pulse wave velocity – PWV) and wave reflections (augmentation index – AI) is now feasible with the use of a brachial-cuff based oscillometric device (Mobil-O-Graph, IEM, Stolberg, Germany). The aim of our study was a) to investigate the reproducibility of 24hour aortic BP and central hemodynamic indices as assessed by the aforementioned device, b) to investigate the circadian pattern of aortic BP and central hemodynamics, as well as the factors associated with the circadian variability of pulse pressure amplification (PPA), c) to examine the association (and possible superiority) of 24-hour aortic over 24-hour brachial ABPM (as well as office brachial and aortic BP) with left ventricular hypertrophy (LVH), left ventricular diastolic dysfunction (LVDD) and common carotid artery (CCA) hypertrophy, d) to investigate the association of aortic blood pressure variability (BPV) and possible superiority over brachial BPV in terms of LVH, LVDD and CCA hypertrophy recognition.Methods: Consecutive subjects referred to our unit for global CVD risk assessment underwent 24hour brachial and aortic ABPM and central hemodynamics evaluation using Mobil-O-Graph. Office brachial and aortic BP were assessed by a validated oscillometric device and implementation of pulse wave analysis respectively. High resolution ultrasound was used for assessing LVH, LDD and CCA hypertrophy. Thirty consecutive subjects had a test-retest ABPM with 1-4 weeks interval to test the reproducibility of the recorded parameters.Results: Intraclass correlation coefficients of 24hour aortic BP and central hemodynamics indicated very good reproducibility, while Bland–Altman plots indicated no evidence of systematic bias. In 497 consecutive subjects (aged 54.1± 12.8 years, 56.7% male, 79.7% hypertensives) we assessed the circadian pattern of peripheral and central hemodynamics. All parameters exhibited a circadian variation. Sleep dipping (i.e. decrease) pattern of PPA, brachial and aortic systolic BP, mean BP and PWV was noted, while on the contrary higher sleep than wake values were observed for brachial PP, aortic PP and AI. A disproportionately higher sleep fall was noted for brachial as compared to aortic systolic BP. The factors independently associated with the sleep-dipping pattern of PPA were age, gender, height, the presence of hypertension, the use of antihypertensive medication, sleep decrease in arterial stiffness (PWV), sleep increase of pressure wave reflections (AI), sleep decrease in heart rate and mean BP. Regression analysis performed in 229 individuals (aged 54.3±14.6 years; 56% men; 75% hypertensives) showed that 24-hour aortic systolic BP was significantly better associated with LVH and LVDD than 24-hour brachial, as well as office (brachial or aortic) BP, independently of age, gender, obesity or treatment. Receiver operator characteristics curve analysis showed a higher discriminatory ability of 24-hour aortic than brachial BP to detect the presence of LVH and LVDD. A high degree of interindividual overlap regarding aortic 24-hour average systolic BP level was found in individuals in whom the corresponding brachial measurements denoted different hypertension levels. It was shown that 24-hour aortic systolic BP was significantly better correlated with intima media thickness (IMT) as compared with brachial systolic BP in 497 subjects (aged 54±13 years, 57% men, 80% hypertensives). Multivariate analysis (adjusted for possible confounders) revealed superiority of 24-hour aortic systolic BP regarding the association with IMT, as well as with carotid hypertrophy. In ROC analysis, aortic BP had a higher discriminatory ability compared to brachial for the detection of carotid hypertrophy. In multivariate models adjusted for possible confounders, it was shown that aortic BPV (and not brachial BPV) was significantly associated with LVH and LVDD. Moreover, only aortic BPV was associated with the presence of carotid hypertrophy, while providing higher discriminatory ability for the detection of carotid hypertrophy as compared to brachial BPV.Conclusions: Non invasive 24hour aortic BP and central hemodynamics assessment by Mobil-O-Graph device provides reproducible values. Possible pathophysiological mechanisms were identified, leading to the sleep dipping of PPA. It was shown that 24hour aortic ABPM, when compared to brachial ABPM, improves the individualized assessment of the BP-associated cardiovascular damage, i.e. LVH, LVDD and CCA hypertrophy. Last, aortic BPV was found to be superior to brachial BPV in terms of association with LVH, LVDD, as well as CCA hypertrophy.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2018
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Argyris, Antonios
- Αργύρης, Αντώνιος
Subjects
dc:subject × 16- Αορτική πίεση
- Περιπατητική καταγραφή αορτικής πίεσης
- Ενίσχυση πίεσης παλμού
- Βλάβη οργάνων-στόχου
- Κιρκάδιος ρυθμός πίεσης
- Μεταβλητότητα αορτικής πίεσης
- Aortic blood pressure
- Ambulatory aortic blood pressure monitoring
- Pulse pressure amplification
- Target organ damage
- Circadian rythm of blood pressure
- Aortic blood pressure variability
- Ιατρική και Επιστήμες Υγείας
- Κλινική Ιατρική
- Medical and Health Sciences
- Clinical Medicine
Rights
dc:rights- Statement dc:rights
-
- BY
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/44806