Democritus University of Thrace (DUTH)
Διερεύνηση της λειτουργίας αντιστροφέων για τη διασύνδεση διεσπαρμένων μονάδων παραγωγής με το δίκτυο χαμηλής τάσης
Abstract
dc:descriptionThe main objective of this PhD dissertation is to thoroughly investigate the anti-islanding capabilities of grid-connected inverters under the high penetration of distributed energy sources (DES) in low-voltage grids.Grid-connected distributed energy sources have been intensively developed over the last decade, increasing their share in power systems worldwide. Photovoltaic systems and wind parks are the most important representative of DES in distribution grids. As those systems continue to increase, electrical power grid undergoes a series of vast changes. Undoubtedly, a major issue of this emerging production model is the issue of unintentional islanding in grid-connected distribution systems. The grid-connected inverter has to detect the unintentional islanding and in time to cease its operation, in order to cope with the international standards. In this context modern grid-connected inverters should be equipped with robust anti-islanding protection features, preserving high quality of the grid injected power.Relevant literature although rich, as an enormous volume of scientific papers has been published on this subject, yet it is not in line with the abovementioned high penetration of DES in local grids. Power quality and voltage flickering issues caused by anti-islanding techniques under high penetration levels are known issues in relevant literature. Moreover, very few of published anti-islanding techniques are compatible with the emerging technology of microinverter (also known as module-incorporated-converter, MIC, technology); the unfolder bridge that is usually employed in these topologies, imposes serious technical difficulties and allows only for anti-islanding techniques that cause disturbances either in the active power or in the frequency of the inverter. It should be noted that this modular technology can be used in large urban areas where space problems are inevitable, providing some advantages over the centralized string and multi-string topologies. It is also worth noting that this technology has been intensively developed in USA, being an excellent solution for the grid interconnection of low-scale DES. Finally, the recommended practice for assessing the anti-islanding features of grid-connected DES considers only a single inverter, tested under certain time frames and load parameter settings, which are recommended by international standards (such as the IEEE 1547.1, IEEE 929-2000 and IEC 62116) and technical directives. However, the abovementioned testing practice fails to anticipate the various problems that occur by the active anti-islanding schemes in the prospect of the massive integration of DES into the grid. As such the performance of active techniques (particularly the harmonic injection ones) might be severely compromised if multiple inverters are connected in the same node.The abovementioned facts have been the motivation to investigate the issue of anti-islanding protection in grid-connected inverters under the high penetration level of DES.In this context, an overview of most popularly used anti-islanding detection methods found in the scientific literature is initially presented. In this direction, the foremost Anti-islanding and Power Quality standards are studied and presented. Where, after thorough discussion, the requirements of modern anti-islanding techniques are formulated.Following, an anti-islanding method that is line with the above requirements is proposed. The proposed method is based on the harmonic injection technique to indirectly evaluate grid impedance, providing fast islanding detection, low impact on the quality of injected power and very low no detection zone (NDZ).In order the proposed anti-islanding scheme to be compatible with the emerging category of microinverters, the harmonic injection capability has been incorporated in their scheme. In particular, a suitable technical solution is proposed that bypasses the unfolding H-bridge of these topologies, without affecting the active power generation of the inverter and without requiring any hardware modification. Moreover, a mathematical model based on the instantaneous power balance theory is presented, being a powerful analysis tool for microinverters operating under complete magnetic discharge (e.g. the Flyback inverter under discontinuous or boundary conduction mode of operation). The proposed model predicts accurately the steady-state operational behavior of the Flyback inverter under current harmonic injection, being a powerful tool for the optimized design of the anti-islanding algorithm.Next a new anti-islanding detection scheme is proposed for microinverters. The proposed scheme periodically injects a second-order harmonic current component of low magnitude (in open-loop mode) and evaluates grid response by means of correlation. The proposed scheme is highly reliable, providing very low NDZ, fast detection, and compliance with the relevant Power Quality and Anti-islanding standards. Additionally, it excels in lower computational cost, reduced fault detection zone (FDZ), and higher output power quality, compared to the referenced anti-islanding schemes that are compatible with microinverters. Last but not least, it can be implemented in microinverters platforms without requiring an output current sensor, being an easily upgradable solution in software level. The main advantages of the new proposed scheme over the initially proposed scheme lie upon its much narrowed FDZ and significantly reduced computational cost.As a next step, the new proposed anti-scheme has been optimized in order to further reduce its FDZ and eliminate NDZ. It is worth noting that the optimization has been partly based on the instantaneous power balance theory that it has been earlier mentioned.An important inclusion of current PhD dissertation is the comprehensive comparison in terms of high DES penetration levels that has been performed among the most suitable anti-islanding methods that are compatible with microinverters (including the methods that have been proposed in this dissertation). Based on the presented results, we concluded that the new proposed correlation method is an excellent solution for anti-islanding protection in microinverters and consequently an excellent alternative over the referenced active power variation, harmonic-injection, and traditional impedance measuring methods.Finally, the effect of multiple inverters has been investigated and a solution has been proposed for the effective application of the new proposed method to multiple inverters interconnected at the same node. The advantages of the proposed solution lie upon its simplified algorithm (effortlessly implemented in the existing control schemes of inverters) and the absent of communication among the inverters (which has been the common practice in order to anticipate the problems that arise from the parallel operation of multiple inverters). In addition, a novel concept (i.e. the Upgrade-Factor, UF) is introduced, indicating the supplementary power of DES that can be installed in the same point of common coupling without compromising the effectiveness of the harmonic injection scheme. As this concept enables the evaluation of harmonic injection schemes prior to the future integration of DES, it could be a substantial addendum into the relevant standards that evaluate the anti-islanding features of DES inverters. A technical solution in software level in conjunction with a droop controller that maximizes UF and reassures the effectiveness of the harmonic injection schemes under the power variations of installed inverters has also being proposed in the current dissertation. It has been concluded that the proposed solution, combined with the proposed correlation anti-islanding method, is a highly effective and comprehensive proposal for the reliable protection of multi-DES interconnected facilities.It should be mentioned that the mathematical analysis presented in this dissertation is validated through simulation, as well as extensive experimental results.
Degree
thesis:*- Grantor dc:publisher
- Democritus University of Thrace (DUTH)
- Year dc:date
- 2018
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Voglitsis, Dionisios
- Βογλίτσης, Διονύσιος
Subjects
dc:subject × 15- Διεσπαρμένη παραγωγή
- Μικροανστιστροφέις
- Αντινησιδοποίηση
- Αντιστροφείς
- Φωτοβολταϊκά συστήματα
- Ποιότητα ισχύος
- Distributed energy resources
- Microinverters
- PV iinverters
- Anti - isladning
- Power quality
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Ηλεκτρολόγου Μηχανικού, Ηλεκτρονικού Μηχανικού, Μηχανικού Η/Υ
- Engineering and Technology
- Electrical Engineering, Electronic Engineering, Information Engineering
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/44955