Aristotle University Of Thessaloniki (AUTH)
Υπολογιστικά πρότυπα ανάλυσης ροής στα νεφρικά αγγεία και στο νεφρικό παρέγχυμα
Abstract
dc:descriptionFor many years, computational fluid engineering has been a very basic tool for producing simulation models in areas such as aircraft modeling and civil engineering. The basis of computational simulation is mathematical simulation. The philosophy of computational simulation science is based on the solution of flow equations, Navier-Stokes equations. Applying the principles of computational engineering fluid to the blood flow to the kidney vessels, we choose the model model that we will study. This is the arterial bow of the kidney. We will use this model to draw conclusions on the physiological function and the behaviour of the blood flow in the case of stenosis. This study describes with absolute accuracy the behaviour of blood in the kidney and renal parenchyma. For the first time it is possible to confirm Bernoulli's laws for blood flow to the kidneys. Physical size, such as pressure, velocity, and intersection, are represented by colour gradation. In this way the change in the physical sizes according to the geometry of the renal vasculature is observed. Physical sizes of shear, velocity and pressure tendency describe the key functional mechanisms of the kidneys. Observing the magnitude of the increase in blood velocity in renal vasculature explains how all the blood is passed through the kidneys despite their very small size in relation to body mass. The speed increases after the blood enters the renal vasculature. Then there is a large decrease in velocity due to the increase in diameter and after the final separation from the branches of the vasculature. Observation in the shear stress behavior and pressure reduction have similarities with similar methods in which the reduction of pressure along the aorta and the renal arteries is the result of stenosis and aneurysm. The shear stress chromaticity gradient varies depending on the area of interest, in order to allow for individual observation of the values in the vascular branches. Thus, the computer computational models represent and simulate in an absolutely accurate manner the physiological and pathological behavior of renal vasculature. Also, three-dimensional imaging is clearly superior to the current ultrasound imaging method. As a result, better imaging combined with numerical values of natural quantities gives the physician the maximum range of information and greater fidelity and reliability in diagnosis. In order to obtain all the information in this PhD dissertation, a funeral graft was used. It was impossible to use more than one for two strict reasons. Firstly, there would be no appreciable difference in the observation of the natural quantities of more geometric differentiation in the image of vascularization and secondly for legal reasons. For this study, a special prosecution was drafted, which allowed the use of only one burial graft for scientific research. The future of nephrology engineering and biomedical engineering in general is proving to be very optimistic. This is evidenced by the fact that publications in this subject are growing rapidly, which means that more and more unknown aspects of the hemodynamic phenomena in the nephrovascular system will be presented and hence the solutions and therapies will be improved. This will result in the success rate of surgical interventions being improved over time, possibly reducing their time to a significant extent, and post-operative complications in patients will disappear. Some operations may include venous and arterial transplantation or implantation of artificial tissues or devices. By conducting a thorough study of the deformations and stresses exerted by these foreign bodies on the interfaces with the normal tissues, it is possible to continuously improve these bodies by altering their material, their properties, and their geometric shape. But they certainly need a reasonable amount of time for their optimal design, because although through experimental devices they can be improved by observing the trends and distortions they cause, but real and meaningful improvement will come from their application to human organisms. Thus, both short-term and long-term impacts will be recorded. In addition, the surgical tools with which surgery is performed can be improved. Obviously during surgery the various medical instruments that enter the various blood vessels can cause damage to the vascular walls or alter local flow causing pressure and deformation of the vascular walls undesirable for the successful operation of the surgery. Regarding kidney diagnosis, improved image analysis through the technological development of tomographic imaging (imaging systems) will help to identify problem areas in a timely and timely manner, which will also lead to the timely avoidance of medical errors. Thus, a potential narrowing in the lumen or even in areas of arterial walls, fibrous tissue and fat can be clearly seen. Also, through the best resolution, gray, or high resolution color imaging, the 3D geometry will be reconstructed in three-dimensional form, representing as much as possible the real situation.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2018
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Lizos, Florentinos
- Λίζος, Φλωρεντίνος
Subjects
dc:subject × 9Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/45010