University of Patras
Ρευστοθερμική ανάλυση και βελτιστοποίηση πρωτότυπης διαδικασίας θερμικής οξείδωσης για την απόσμηση εγκαταστάσεων βιολογικών καθαρισμών
Abstract
dc:descriptionThis doctoral thesis deals with the fluid-thermal analysis of an original gas -decontamination process of waste treatment plants. The study - construction and installation of the first prototype unit in 2004 at a waste treatment plant at KALLIMANIS SA in Egio with a treatment capacity of 2000 Nm3/h for the implementation of the PRAXE PHASE A’ program was preceded. Due to the excellent results obtained, it was also adopted by large production industries and is operating from 2004 onwards, units of various capacities 2000 Nm3/h KALLIMANIS SA EGIO, 22000 Nm3/h ZOONOMI SA LEHEO of KORINTHOS, 60.000 Nm3/h FEEDUS SA VIPE of Patras, 75.000 Nm3/h ECOFEED SA VIPE of Patras with excellent operating results The aim of the doctoral dissertation is the theoretical foundation of the above work from the initial conception of the idea for which international and domestic patents were granted, the construction - installation and commissioning of the units. After all the methods for neutralization of the gaseous pollutants are presented and the comparative evaluation is made, it was chosen as the theoretical model for the determination of the thermal flows and finally of the temperatures measured in the combustion chamber of one of the operating processing units of 22.000 Nm3/h in LEHEO KORINTHOS ZOONOMI S.A. from in 2005, of thermal radiation. For this reason, the GSRT in 2009 rewarded this work and ratified the PRAXE PHASE B’ program amounting to 1,632,000 euro for the creation of a unit of construction. Because the temperature in the combustion chamber is in the order of 750 °C the heat transfer is almost entirely through the thermal radiation. For this reason, the thermal radiation model was selected. The results are identical for any size of the thermal processor. The thermal zones method and the charts of H.Hottel's experimental data for water vapor and carbon dioxide emission were selected as the first method and for comparison and verification Leckner's equations. Direct field exchanges with Hottel diagrams were determined as a first method and with the R.J.Tucker tables for comparison and verification, and two-way determination of total thermal radiation exchanges for countless times of reflection in the combustion chamber was determined. The thermal radiation model was applied and heat flows determined. General equations of thermal balances were determined and thermal radiation for each surface and gas volume to which the combustion chamber was originally divided. Then the Stefan-Boltzman law computed the corresponding temperatures that were identified with the data of the operating unit, which was also the scientific challenge of this dissertation. Then, due to the wave nature of thermal radiation, we set out the general equations of Maxwell's electromagnetic wave and, after processing them, we arrived at the general equation of thermal radiation. Because the thermal radiation is an electromagnetic wave. Finally, we presented a sophisticated version of a gas neutralization unit, particulate matter and optical cloud, which will come into operation shortly and is nowhere in the world.
Degree
thesis:*- Grantor dc:publisher
- University of Patras
- Year dc:date
- 2019
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Pittas, Nicholas
- Πήττας, Νικόλαος
Subjects
dc:subject × 17- Απόσμηση
- Tριβάθμιος θερμικός επεξεργαστής
- θάλαμος καύσης
- Θερμική οξείδωση
- Mέθοδος των θερμικών ζωνών
- Eκπομπές ρυπογόνων αερίων
- Θερμική ακτινοβολία
- Deodorizing system
- Three bed thermal regenerative oxidizer
- Chamber of combustion
- Thermal radiation
- Zone method
- AIR pollutants
- Επιστήμες Μηχανικού και Τεχνολογία
- Άλλες Επιστήμες Μηχανικού και Τεχνολογίες
- Engineering and Technology
- Other Engineering and Technologies
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/45395