Aristotle University Of Thessaloniki (AUTH)
Βελτιστοποίηση της απόδοσης αιολικού συστήματος με επαγωγική γεννήτρια διπλής τροφοδότησης
Abstract
dc:descriptionIn this PhD dissertation, two new control techniques have been proposed, that improve the efficiency of a wind energy conversion system (WECS) with a doubly fed induction generator DFIG. To achieve this goal, the electric losses of the DFIG should be minimized and the mechanical energy that is absorbed by the wind turbine should be maximized. The loss minimization is attained by properly controlling the stator electric frequency and the magnetic flux of the DFIG. Since in a conventional WECS with DFIG, the efficiency cannot be increased by means of magnetic-flux weakening control methods because the stator is directly connected to the electric grid, two novel control schemes have been proposed so as the advantage of lower requirements for power converter capacity against the other types of electrical machines is still valid. In the first control scheme (which is denoted as “Method 1”), a high efficiency control strategy is proposed that provides power loss reduction in the DFIG and maximum power in the wind turbine. Therefore, from the same wind energy potential, increase in the generated electric energy can be attained. Moreover, the cut-in wind speed is reduced and thereby, extension of the exploitable wind speed region is accomplished. The power loss reduction in the DFIG is attained through stator frequency and flux-weakening control while maximum harvesting from the turbine is achieved by properly controlling the rotor speed. For the implementation of the proposed high efficiency control strategy, a new system layout is proposed that does not affect considerably the cost of the WECS.In the second control scheme (which is denoted as “Method 2”), the power loss minimization is based on the flux-weakening technique realized by the proper control of the output voltage of the rotor side grid converter and the MPPT is accomplished by regulating the rotor speed through the q-axis rotor current of the rotor side generator converter. An experimental procedure for determining the controllers’ parameters has been presented and, therefore, the knowledge of the WECS model is not required. For the implementation of the optimal efficiency control system, a new structure of the WECS has been adopted so as the cost has not been considerably affected compared to the conventional system. This is accomplished by changing the connections of the grid transformer. Although the Method 2 does not increase the cost of system because it does not require additional hardware, it does not have the capability of controlling the electric stator frequency and consequently, the electric losses cannot be minimized. This means that improvement in the efficiency of the WECS with a DFIG can be attained, but not the optimization. The effectiveness and practicality of the two control methods of a WECS with DFIG have been validated with simulation and experimental analysis. Several simulation and experimental results have been presented to demonstrate the operating improvements that are attained by the two control methods.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2019
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Karakasis, Nektarios
- Καρακάσης, Νεκτάριος
Subjects
dc:subject × 12- Επαγωγική γεννήτρια διπλής τροφοδοσίας
- βελτιστοποίηση απόδοσης αιολικού συστήματος
- Aνεμο - τουρμπίνα
- Αιολικά συστήματα
- Doubly fed induction generator
- Efficiency increase
- Wind turbine
- Wind energy conversion system
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Ηλεκτρολόγου Μηχανικού, Ηλεκτρονικού Μηχανικού, Μηχανικού Η/Υ
- Engineering and Technology
- Electrical Engineering, Electronic Engineering, Information Engineering
Rights
dc:rights- Statement dc:rights
-
- BY_NC_ND
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/45560