Επιρροή μορφολογικών προβλημάτων στη σεισμική συμπεριφορά κατασκευών οπλισμένου σκυροδέματος
Abstract
dc:descriptionIn the present PhD thesis the seismic performance of reinforced concrete (RC) frame structures with irregularities in terms of both global and local requirements of the structures, are investigated. The research carried out includes two general sections - morphological problems.The first section includes the investigation of the seismic behavior of multi-story structures with morphological problems on the first-floor, that lead to soft first floor configuration. The influence of the morphology of the first floor of six-story reinforced concrete frame structures on their seismic behavior was studied, namely the cases of construction (a) with tall first - floor and (b) without beams at the first - floor. The effects of the first - floor irregularity on the RC frame structure performance stages at global and local level (limit states) are investigated. Assessment based on the Capacity Spectrum Method (ATC-40), on the Coefficient Method (FEMA 356) and on the N2 method is also examined. The investigation includes a poly-parameter program of static inelastic analysis and inelastic step-by-step analysis for the following cases:Case A: Buildings with equal floor heights (as pilot constructions). Case B: Buildings with a tall first - floor and equal floor heights on the other floors. Case C: Buildings with equal floor height and slab-column connections without beams at the first floor.Also, the existence of masonry infilled walls is studied and for this reason the following cases were studied: (a) without infills (bare frame), (b) as fully infilled frame structure and (c) as pilotis - type frame structure.For the purpose of this investigation, static inelastic analysis and dynamic step-by-step inelastic analysis were performed at selected “check” points and at various performance levels to identify the most critical types of morphological problems in terms of both global and local requirements of the structures. The 6-story structures were checked at the following performance levels: (i) Near Collapse (NC): 2.475years, corresponding to a probability to exceedance of 2% in 50 years and (ii) Significant damage (SD): 475years, corresponding to a probability to exceedance of 10% in 50 years.Results in terms of failure modes, capacity curves, interstory drifts, ductility requirements and infills behavior are presented. From the results it can be deducted that the global seismic capacity of the structures is decreased due to the considered first - floor morphology irregularities in comparison to the capacities of the regular structure being less critical in the Case B. The maximum interstory drifts are significantly increased at the first - floor for the Case B (tall columns) and at the second floor for the Case C (slab-column connections without beams) in comparison to the regular structures. An increase of the demands for interstory drift is observed at the first floor level due to the considered irregularities, while the open ground floor structure (pilotis type) leads to even higher values of interstory drift demands at the first story.Also it can be observed that the performance points obtained by FEMA and N2 method are very close to each other and to step by step seismic analysis results with the ATC method being the most conservative. There is a minor increase of the values due to the different morphology of the first floor, however there is a decrease when the masonry infilled is incorporated. Regarding the local requirements, the morphological problems on the first floor (Case B - high columns, Case C - slab-column connections without beams at the first floor) leads to soft story mechanisms at the first floor. More spesifically, there was an increase in the flexural requirements for the beams and columns on the first floors compared to the corresponding requirements of the regular structure. The critical flexural behavior as well as the inelastic behavior of the masonry infilled occured on the first and second floor where the morphological problem existed with the most critical type of ground morphology being the Case C. Generally, it can be concluded that the behavior of the structures and the influence of morphological problems depend on the level at which the seismic response of the structure is checked.In the second section the asymmetric structural pounding is investigated and including multi-parametric seismic response analysis of multi-story reinforced concrete structures that partly interact with adjacent structures. 3D simulation was carried out and special attention was paid to the torsional movement that introduced into the structural system of these structures due to their interaction with the adjacent structures.For the purposes of this investigation, a parametric analysis was carried out in which more than 1200 dynamic step-by-step inelastic analysis were conducted, in which 408 cases between adjacent reinforced concrete structures were studied. In particular, the asymmetric interaction of i) a 8-story reinforced concrete structure with adjacent structures with ns = 1, 2, 3, 4, 5, 6, 7, 8 floors and ii) a 4-story reinforced concrete structure with adjacent structures with number of floors ns = 1, 2, 3, 4 were investigated. For both multi-story structures, two different types of structural interaction are defined: (a) Diaphragm-to-diaphragm collisions (Type A). (b) The floor levels of the two structures are different. Consequently during the seismic oscillations the diaphragms of the first one impact the columns of the other (Τype B).Due to that fact pounding occurs only in only one (Case 1) or in two (Case 2) columns of the structures and since the other columns are free to move without restrictions a torsional behavior is introduced (asymmetric pounding). Each pounding case is examined for three gap distances; first considering that they are in contact (gap distance dg=0) and further that there is a gap distance equal to 1 or 2 cm (dg=1 and 2 cm).The torsional behavior of multi-story structures introduced due to the impacts to the adjacent structures is a critical issue of this morphological problem and has significant results on both global and local requirements of the structures. Results in terms of base shear, maximum interstory drifts, maximum story torsions, torsional moment at the base floor, shear and flexural demands at the column that suffer the hit are presented.From the results it can be clearly deduced that asymmetric type of pounding causes significant torsional movement and high value torsional moments and torsion at the floors in the multi-story structures, although its plan view is symmetric and in the cases it vibrates without the pounding effect it presents insignificant torsional moment and consequently no torsional movement. Highest increasing ratio has been observed in Case 1, as in this case pounding occurs only in one (Case 1) column of the structures and since the other columns are free to move without restrictions, torsional behavior is introduced (asymmetric pounding). Comparing the two poundings types, Type A and Type B, higher requirements have been observed for the case in which contact occurs at floor levels and the torsion movement is concentrated on the floors (Type A) . In Type B which includes cases where the story heights of the multi-story structure are different main problem is the development of a shear critical state in the columns that suffer the hit.As expected the torsional movement of the examined building highly influences the distribution of the developing shear forces in the columns. For the Type A, it can be seen that the shear forces of the columns in the direction of the earthquake excitation (x-direction -VX) decrease due to the movement restraint provided by the adjacent structures at this point of the building whereas at the same time significant shear forces are observed in the normal direction (y-direction-VY). In the Type B there are a significant increases in both directions (VX and VY). Pounding induced torsional vibration influences the shear and flexural demands of the column C1 and significantly increases the demands of the columns that experience the hit due to the inter-story pounding between the adjacent structures. In more detail, pounding induced torsional vibration changes the ductility demands of the columns and significantly increases the ductility requirements of the column C1. Highest increasing ratio has been observed at the column C1up since it has a shorter length and the damages concentrate herein. In addition, it can be observed that in all pounding cases for the column of the 8-story structure that suffers the hit from the top floor slab of the adjacent structure there are pairs of V - N values that lie outside the line limit of the available strength. This means that there are time periods during the seismic response of the building during which the developed shear forces exceed the available shear capacity and therefore a potential of a local shear brittle failure can be expected.
Degree
thesis:*- Grantor dc:publisher
- Democritus University of Thrace (DUTH)
- Year dc:date
- 2019
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Naoum, Maria
- Ναούμ, Μαρία
Subjects
dc:subject × 14- Μορφολογικά προβλήματα πολυώροφων κατασκευών
- Έκκεντρη αλληλεπίδραση
- Στροφική συμπεριφορά κατασκευών
- Κατασκευές τύπου pilotis
- Αλληλεπίδραση κατασκευών
- Morphοlogical problems of multistory structures
- Assymetric seismic interaction
- Torsional behavior
- Pilotis type frame structures
- Inter - story pounding
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Πολιτικού Μηχανικού
- Engineering and Technology
- Civil Engineering
Rights
dc:rights- Statement dc:rights
-
- BY_NC_ND
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/45832