National Technical University of Athens (NTUA)
Αξιοποίηση μετατροπέων αιολικών πάρκων για τη βελτίωση της ευστάθειας τάσεως ΣΗΕ
Abstract
dc:descriptionThis PhD dissertation investigates the effect of reactive support of Wind Farm (WF) converters on the maximum power transfer of a power transmission system. Specifically, the aim of this work is to assess the power transfer limit increase (and hence the long-term voltage stability enhancement) by a proposed emergency maximum reactive support control scheme, in the presence of stochastic wind farm generation.The examined systems include transmission lines where Wind Farms (WF) are connected through dedicated MV distribution feeders. The detailed data for the feeders are taken from actual wind farms connected to the Hellenic System in the area of Peloponnese. The wind farm feeders consist of HV/MV substations with power transformers equipped with Load-Tap Changers, switched capacitor banks and power electronic converters AC/DC/AC connecting the WFs. These devices regulate and control the reactive power injected by the wind farms. The WF and the wind generator controllers have the ability to regulate the reactive power injected to the connection bus. At first two different test systems are simulated with one and two WFs respectively, while later the whole Hellenic Interconnected System (HIS) is simulated.In order to simulate the effect of wind variability in system loadability limit, two correlated wind speed time series are considered as input to the wind generators. The model used to extract the active power time series simulates the operation and control of a variable speed wind generator, specifically of a doubly-fed asynchronous generator.To assess the contribution from each WF, three different control strategies of the wind farm converter are implemented, more specifically the unity power factor control (UPF), the WF constant voltage control (CVC) and a proposed intelligent emergency control with maximum available reactive support command (Emergency Maximum Reactive Support, EMRS). The EMRS control scheme requires only one triggering signal requesting maximum reactive support from the distributed source (in this case the WF). This can be achieved through an inexpensive and easy to acquire communication channel, either wireless (e.g. mobile phone) or through line courier communication. This exercise focuses also on new converter instability mechanisms, not so far described in power system stability classifications. The converter instability condition refers to the inability of the network to receive the generated power (minus active losses) under adverse network conditions, due to its diminishing voltage. This short-term power system instability arises when the converter is assigned to support the transmission system through reactive power injection. Furthermore, a protection scheme, able to detect and prevent this type of instability is proposed.Next, the internal structure and topology of the wind turbine generators (WTGs) that compose a wind farm are investigated (a detailed model of a WF is simulated). The model of each wind turbine includes a detailed implementation of the voltage, the active and reactive power control systems. In addition, a central control system of the Wind Farm is implemented, through which control signals are distributed to the individual wind turbines. A method is then proposed for the determination of an aggregate model for the simplified equivalent representation of a Wind Farm, focusing on the application to voltage stability studies. Furthermore, a full simulation is compared with the Quasi-Steady-State (QSS) for the approximate Wind Farm model of an aggregated equivalent wind turbine under variable wind. The comparison aims to highlight the Quasi-Steady-State as a reliable way of assessing the voltage stability limit on a transmission system. Finally, the converter instability examined earlier with the QSS method, referring to the inability of the network to receive the generated power under adverse network conditions and constant current limitation, is now investigated with the full simulation model. Protection schemes are proposed, able to prevent this type of instability by retuning the Maximum Power Point Tracking controller parameters, in order to better interact with the pitch controller.Afterwards, with the use of stochastic Markov models, an algorithm is developed for the production of synthetic time series. After the discretization and the extraction of the probability transition matrix of the original time series, which corresponds to real wind speed measurements, the effect of various parameters on the reproduction of autocorrelation factors and probability density function is examined, in order to choose the most fitting model for each time series. Finally, the produced synthetic time series from each chosen Markov model are used for the probabilistic simulation of the Wind Farms. The use of a Markov Chain Monte Carlo (MCMC) method is considered as an appropriate representation of wind power and its statistics in this exercise. For the simulations of the first test system comprised by one wind farm, the software package MATLAB is used, while for the test system consisted of two wind farms, as well as for the whole Hellenic Interconnected System, the long-term Quasi-Steady-State simulation program WPSTAB.
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2019
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Souxes, Theodoros
- Σουξές, Θεόδωρος
Subjects
dc:subject × 36- Μέγιστη μεταφερόμενη ισχύς
- Διεσπαρμένη παραγωγή
- Αιολικά πάρκα
- Μεταβλητότητα ανέμου
- Έλεγχος αέργου ισχύος
- Μέγιστη άεργος υποστήριξη εκτάκτου ανάγκης
- Όριο φόρτισης συστήματος
- Ευστάθεια τάσεως
- Καμπύλες ισχύος - τάσεως
- Αστάθεια μετατροπέα ηλεκτρονικών ισχύος
- Προσεγγιστικό ισοδύναμο μοντέλο Αιολικού πάρκου
- Αλληλεπίδραση ελεγκτών γωνίας - βήματος και μέγιστης απολαβής ισχύος
- Μοντέλα Markov
- Στατιστική ανάλυση
- Πιθανοτικές προσομοιώσεις
- Συνθετικές χρονοσειρές
- Maximum power transfer
- Distributed generation
- Wind farms
- Wind variability
- Reactive power control
- Emergency maximum reactive support
- System ioadability limit
- Voltage stability
- Power - voltage curves
- Converter instability
- Aggregate wind farm model
- Pitch control and maximum power point tracking control interactions
- Markov models
- Statistical analysis
- Probabilistic simulations
- Synthetic time series
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Ηλεκτρολόγου Μηχανικού, Ηλεκτρονικού Μηχανικού, Μηχανικού Η/Υ
- Engineering and Technology
- Electrical Engineering, Electronic Engineering, Information Engineering
Rights
dc:rights- Statement dc:rights
-
- BY
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/46074