Back to search

University of Crete (UOC)

A point-of-care, microfluidic - based microscanner for the identification and counting of single cells

Abstract

dc:description

Blood cell counting is related to the diagnosis and therapy of various diseases, from infections to blood disorders and cancer treatment. However, the time consuming procedures and the increased cost of standard medical equipment act as serious obstacles in the early screening of a disease. To meet this challenge, there is an emerging trend towards a patient-centered healthcare, that provides medical examination, diagnosis and treatment management, at the point of care. Profiting from the recent advances in the field of Micro-ΕlectroΜechanical systems (MEMS), micro-optics and micro-fluidics, the present thesis attempts to present a novel platform technology for blood cell identification and counting at the point of care. A portable optical imaging scanner has been developed, consisting of 3 novel components: (1) A microfabricated lens array that enables extended field of view sample imaging with single cell resolution. The lens array combined with a light source enables imaging in trans-illumination mode. (2) A novel design, integrating a micro-LED array and a mini-lens array on the same silicon chip, was additionally developed for imaging sample in epi-illumination mode. (3) A microfluidic chip that performs specific cell capturing from undiluted, whole blood samples. The characterization process of the individual subsystems demonstrates: (a) high optical resolution reaching 1 μm under conditions of maximum magnification by the system at 4X with trans-illumination scheme; (b) the ability to screen the entire sample surface with maximum extend of 2.5 cm2; (c) the achievement of 8.8 μm resolution in reflection scheme by the use of the device incorporating the light source on the same chip with the microlenses, (d) the reduction of the optical length of the total optical structure below 2.5 mm and finally (e) the achievement of a clinically negligible error in white blood cell capturing in the microfluidic device, below 3.8%, in comparison with the gold standard of flow cytometry and from whole, unprocessed, undiluted blood. The developed system constitutes a platform technology; it is applicable to a wide range of diseases and blood disorders. The conducted research proves the feasibility of single cell identification and counting in full compliance with the requirements of World Health Organization for point-of-care devices: they need to be affordable, easy-to-use, battery operated and deliverable unconditionally to all.

Degree

thesis:*
Grantor dc:publisher
University of Crete (UOC)
Year dc:date
2019

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Korompili, Georgia
  • Κορομπίλη, Γεωργία

Subjects

dc:subject × 24

Rights

dc:rights
Statement dc:rights
  • BY_NC_SA
Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/46085

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Korompili, Georgia; Κορομπίλη, Γεωργία. A point-of-care, microfluidic - based microscanner for the identification and counting of single cells. University of Crete (UOC), 2019. http://hdl.handle.net/10442/hedi/46085