Abstract
dc:descriptionThe absence of a single reliable detection method makes estimating surgeons’ mental stress during an operation difficult to quantify and interpret. Although several non-invasive stress measuring methods have been proposed, most studies have used only one or two stress estimation parameters and produced conflicting results. Τhe first objective of this study was to assess the feasibility of a new, easy to wear watch-sized device to noninvasively measure cardiac stress parameters such as heart rate (HR) and heart rate variability (IBI) which are usually measured by means of a Holter monitor, as well as Electrodermal activity (EDA). The second objective was to concomitantly measure the responses of seven noninvasive stress indices and compare them to the video score (VS) achieved by novices in a stressful simulation environment. Namely, we used one subjective method (STAI) plus the three abovementioned ones derived from the wrist-worn device (HR, IBI, EDA) as well as the salivary levels of cortisol, alpha-amylase and IgA. Twenty-one male novice trainees were enrolled. After an orientation phase, they wore a wrist device that measures heart rate (HR), interbeat interval (IBI) duration, and electrodermal activity (EDA) as well as a Holter ECG rhythm monitoring system (HM). A saliva specimen was collected for cortisol (sC), alpha-amylase (sAA), and secretory immunoglobulin A (sIgA) measurements (baseline phase, BL). Then the simulation exercise phase (E) started, with the subjects trained on a basic suturing module for 15 minutes. Immediately after, another saliva sample was collected. The whole experiment was videotaped, and VS was calculated. The percentage (E-BL)diff of each of the six parameters was calculated and compared with VS using Pearson’s correlation coefficient as well as Akaike Information Criterion (AICc).Data analysis showed: a) When compared to STAI, electrodermal activity exhibited the best correlation, sensitivity and specificity, b) the device derived cardiac parameters highly correlated with the reciprocal Holter values during all experiment phases and c) EDAdiff showed the best correlation with VS, followed by IBIdiff and HRdiff. Among the saliva biomarkers, sAAdiff showed the best correlation in comparison to sIgAdiff and sCdiff.It is concluded that this wearable device is an easy to use and well accepted by the participants noninvasive tool, which can provide accurate stress estimation in our simulation setting. Additionally, it can replicate Holter derived stress related heart parameters, thus eliminating the need to wear a rather cumbersome device. In our simulation setting, sympathetic ANS stress parameters (EDA, IBI, HR, sAA) could best describe the novice trainees’ performance, but sC and IgA could not.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2019
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Georgiou, Konstantinos
- Γεωργίου, Κωνσταντίνος
Subjects
dc:subject × 26- Στρες
- Εκτίμηση στρές
- Μέτρηση στρές
- Προσομοίωση
- Λαπαροσκόπηση
- Χειρουργική
- Χειρουργική προσομοίωση
- Φορητές συσκευές
- Βιοδείκτες
- Σάλιο
- Βιολογικοί δείκτες σάλιου
- Stress
- Stress estimation
- Simulation
- Laparoscopy
- Surgery
- Surgical simulation
- Wearables
- Wearable devices
- Biomarkers
- Saliva
- Saliva biomarkers