University of Thessaly (UTH)
Τυποποίηση στελεχών Legionella Pneumophila από περιβαλλοντικά δείγματα και συρροές κρουσμάτων με Matrix assisted laser desortion ionization Time-of-Flight Mass Spectrometry (ΜALDI-TΟF MS)
Abstract
dc:descriptionPresently, Legionella risk assessment focuses on detection of the microorganism in water samples. Since human disease is caused mostly by Legionella pneumophila serogroup 1 (Lp1) and has been associated with the presence of pathogenicity locus lvh and rtxA, it is important to assess not only Legionella serogroup but the aforementioned virulence factors also in order to perform complete risk assessment.Aim: (i) Establish and validate a simple, rapid and robust MALDI-TOF MS-based method for the assignment of Lp isolates to serogroup 1 or 2-15. (ii) Identification of peak biomarkers in order to detect the presence of locus lvh and rtxA to the isolated strains during environmental investigations.Method: Fifteen (15) reference strains and 150 Lp environmental isolates (80 Lp2-15 and 70 Lp1 strains) were used. Eight (8) Lp2-15 strains, were serotyped using monoclonal antibodies (Mab), while the remaining environmental isolates were serotyped using latex agglutination test. All the strains were PCR-tested for the presence of lvh and rtxA locus. Independent training and validation strain sets were constituted; all the strains were protein-extracted and submitted to MALDI-TOF MS analysis. The obtained raw spectra were introduced into the Mass-Up software platform for biomarker detection both for serogroup assignment and pathogenicity locus detection. Validation of the assigned biomarkers followed using the validation set strains.Results: For serogroup assignment, the Mass-up analysis indicated five potential discriminating peaks and classified correctly 115 out of 132 validation set strains displaying sensitivity of 87.5% (95%CI:77.59-94.12%),specificity of 86.67% (95%CI:75.41-94.06%) and 87.12% accuracy (95%CI:80.18-92.32%). Concerning the pathogenicity locus detection, the Mass-up analysis indicated two ion peaks for rtxA locus discrimination and one peak for lvh locus discrimination. Concerning the lvh virulence gene, the algorithm classified correctly 113 out of 137 positive and all negative strains-14 in total-showing sensitivity 82.48% (95%CI:75.06-88.44%), specificity 100.00% (95%CI:76.84-100.00%) and 84.11% accuracy (95%CI:77.28-89.54%). For rtxA locus, 134 out of 134 positive and 14 out of 17 negative strains were correctly classified with sensitivity 100.00% (95%CI:97.28-100.00%), specificity 76.47% (95%CI:50.10-93.19%) and accuracy 97.35% (95%CI:93.36-99.27%). Conclusion: MALDI-TOF MS, using the protein extraction protocol, displayed good performance for Lp serogroup assignment and detection of the lvh and rtxA virulence genes. Standardization and evaluation of the method using the direct plating technique, in order to simplify the protocol, could contribute to the rapid, inexpensive and easy risk assessment and investigation for LD cases.
Degree
thesis:*- Grantor dc:publisher
- University of Thessaly (UTH)
- Year dc:date
- 2019
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Kyritsi, Maria
- Κυρίτση, Μαρία
Subjects
dc:subject × 13Rights
dc:rights- Statement dc:rights
-
- BY
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/46517