Back to search

National and Kapodistrian University of Athens

Βλάβες Essex-Lopresti και επιμήκης κερκιδωλενική αστάθεια: εμβιομηχανική μελέτη για την ανακατασκευή της κεντρικής δέσμης της μεσόστεου μεμβράνης του αντιβραχίου

Abstract

dc:description

The longitudinal stability of the forearm relies primarily on the integrity of the radiocapitellar articulation, whereas the interosseous membrane and the triangular fibrocartilage complex act as secondary stabilizers. In case of an Essex-Lopresti lesion all three structures are disrupted rendering the forearm unstable in both longitudinal and transverse plane. The re-establishment of the radiocapitellar joint remains the cornerstone of treatment, as Pier Gordon Essex-Lopresti had already recognized in 1951 in order to prevent proximal migration of the radius. However, a better understanding of the functional anatomy and biomechanics of the interosseous membrane has offered a new perspective on the treatment of these notoriously difficult injuries. The central band is the thickest and most consistent structure of the interosseous membrane. It functions as a strong ligament between the two bones, while it permits partial load transfer from radius to ulna. Thus, it has been recognized that central band reconstruction has the potential to re-establish a near normal loading pattern through the forearm and could optimize long-term clinical outcomes. The objective of our study was to assess the capacity of three different reconstruction techniques to restore the forearm longitudinal stability. All three techniques employ a regionally harvested autograft (pronator teres, brachioradialis and flexor carpi radialis tendons respectively). An Essex-Lopresti lesion was gradually simulated in seven fresh frozen cadavers by excising the radial head and sectioning the interosseous membrane. Then, each reconstruction procedure was used to each specimen consecutively. The specimens were submitted to mechanical testing by applying proximally migratory forces in each situation. The relative radioulnar displacement was assessed fluoroscopically at wrist level. The pronator teres tendon achieved the greatest reduction (94.2% correction with respect to the intact interosseous membrane/radial head out state, followed by brachioradialis (91.7%) and flexor carpi radialis (85%). However, no statistically significant differences in displacement data or strength were detected between the techniques. None of the reconstruction procedures had any adverse impact on prono-supination range. A regression analysis was also performed to investigate whether outcomes were affected by graft’s orientation. A moderate negative linear correlation was detected between graft’s angle and radioulnar displacement. Our findings suggest that any of these techniques may enhance the radioulnar stability and could be safely applied in vivo along with radial head replacement. In any case, the clinical significance of our findings has to be established by appropriately designed clinical studies.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2019

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Masouros, Panagiotis
  • Μασούρος, Παναγιώτης

Subjects

dc:subject × 14

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/46746

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Masouros, Panagiotis; Μασούρος, Παναγιώτης. Βλάβες Essex-Lopresti και επιμήκης κερκιδωλενική αστάθεια: εμβιομηχανική μελέτη για την ανακατασκευή της κεντρικής δέσμης της μεσόστεου μεμβράνης του αντιβραχίου. National and Kapodistrian University of Athens, 2019. http://hdl.handle.net/10442/hedi/46746