University of Thessaly (UTH)
Development of methodologies for performance analysis of grid-connected photovoltaic systems
Abstract
dc:descriptionThe growth of renewable energy - especially photovoltaic energy worldwide, and –more specifically- in Greece, is remarkable. There exist numerous grid-connected PV systems in Greek territory which have already completed ten years of operation. A challenging task for these systems is performance analysis, investigation of possible degradation in system’s efficiency, formulation of a detailed solar potential record for each region and the study of factors which affect PV efficiency in each region. Furthermore, their inspection and maintenance needs are increasing fast. Thus, it becomes necessary to systematically characterize and classify the more important types of defects and correlate them to possible causes. This study has set five objectives which have been investigated through specific experimental and test set-ups. These set-ups comprise grid-connected PV installations in Thessaly and one off-grid experimental set-up in the University of Thessaly. The first objective was to present real-world efficiency data for photovoltaic panels and photovoltaic parks, as function of air mass and environmental conditions. The experimental set-up consisted of a 2MWp grid-connected system as well as a single PV panel. The PV efficiency is observed to deteriorate quickly when the solar altitude is less than 45 degrees, or the solar insolation drops below 200 W/m2. The second objective was to attempt a systematic compilation of defects and devise a simple procedure to spot them by means of optical inspection, infrared inspection and electrical inspection. The experimental set-up consisted of five grid-connected 99,84kWp PV systems and one 9,88kWp rooftop installation. A methodology and guide for on-site PV inspection has been developed that may also be employed for screening newly installed PV panels on site. The third objective was the formulation of an evaluation procedure for the photovoltaic plant’s performance, based on routinely collected, real world system monitoring data. The role of air mass and clearness index variations in this context is well established and the analysis is conducted with the aid of these factors. The experimental set-up consists of a 99,84kWp grid connected PV system in Central Greece. The analysis has been carried out according to the following three directions: (i) evaluation of three existing models, (ii) performance ratio calculation and (iii) the formulation of an evaluation procedure based on normalization to Standard Reporting Conditions. A 10% fluctuation in yearly energy production was observed for the period 2013–2015. This fluctuation was investigated by means of performance ratio analysis, normalization procedure and model comparison. All results pointed to a decrease in PV panel’s efficiency from the first year of operation. However, this was a small decrease covered by the terms of the manufacturer’s warranty. The fourth objective was to analyze the performance of a grid-connected 12,84 kWp PV system in central Greece for a six year period of operation. The analysis methodology was based on three axes: (i) calculation of the daily PR and yearly PR and their comparison for the 6 years of operation. The daily PR is further correlated with the averaged clearness index in order to assess the atmospheric effect on the PV performance. (ii) Application of a mathematic model, which describes PV power, to the available data. Computed values act as the reference values and deviation of the measured values thereof hint to probable changes in PV system performance. (iii) Computation of normalized efficiency to STC conditions. This included the computation of DC power from available AC data and inverters’ efficiency, temperature normalization according to the temperature coefficients of manufacturer and comparison of efficiency at various weather conditions and computation of yearly average values, respectively, with Air mass. The analysis results hint to a small performance deterioration over the years, with degradation rates ranging from 1 to 4%. The fifth objective was the performance analysis of a grid-connected PV system with focus on the effects of dust accumulation on PV panels surface and aerosol mass concentration in Central Greece. The methodology of analysis developed in the previous objective is employed in combination with aerosol measurements. The results show that only heavily soiled surfaces have significant impact on PV performance and particularly a decrease of 5,6%. On the other hand, light or medium soiling have negligible impact on PV performance. As far as aerosol mass concentration is concerned, it does not significantly influence PV normalized efficiency in clear sky conditions.
Degree
thesis:*- Grantor dc:publisher
- University of Thessaly (UTH)
- Year dc:date
- 2019
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Roumpakias, Elias
- Ρουμπακιάς, Ηλίας
Subjects
dc:subject × 10- Φωτοβολταϊκά
- Ανάλυση απόδοσης
- Πραγματικές συνθήκες
- Photovoltaics
- Performance analysis
- Grid-connected systems
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη Ηλεκτρολόγου Μηχανικού, Ηλεκτρονικού Μηχανικού, Μηχανικού Η/Υ
- Engineering and Technology
- Electrical Engineering, Electronic Engineering, Information Engineering
Rights
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/46825