Back to search

University of Thessaly (UTH)

Μακροπρόθεσμα αποτελέσματα επιφανειακής ολικής αρθροπλαστικής γόνατος με ασύμμετρους κνημιαίους κονδύλους (GENESIS I)

Abstract

dc:description

From 1992 to 2000, ninety consecutive patients with 117 knees underwent a cemented total knee arthroplasty using the Genesis I prosthesis in Achillopouleio General Hospital of Volos. Inclusion criteria were patients with primary knee osteoarthritis, a varus angular deformity less than 15º and a flexion contracture less than 10º. From the initial group, thirteen patients with 18 knees died from causes unrelated to the surgery. Eight patients with 8 knees were lost to follow-up. Thus, 74 patients with 91 knees were finally included in the study. The median follow-up was 21.5 years (range 18 to 26). Median age of the patients was 69,2 ± 5.34 years (range 58 - 83 years) and the median age of the patients during the follow-up was 85,47 ± 4,97 years (range 73 – 94). A posterior cruciate-retaining Genesis I (Smith and Nephew Richards Inc) prosthesis was used in all cases. The prosthesis consisted of a femoral, a tibial component, a polyethylene insert and a polyethylene patella component. The femoral and the tibial components were placed with the use of cement. It is an easy-to-use system featuring an anatomic, chrome - cobalt femoral component with a wide, deep and extended trochlea groove, a titanium alloy asymmetric tibial baseplate that provides maximum bone coverage and a bi-convex-shaped polyethylene patella. The polyethylene-bearing surface is asymmetric to maximize implant contact. Under spinal anesthesia and the use of a tourniquet, a classic medial parapatellar approach through a midline skin incision was performed. A posterior cruciate-retaining Genesis I prosthesis was used in all cases. Patellar resurfacing was performed in 14 cases where severe patella osteoarthritis occurred. An auto-transfusion system was used in all patients. Chemoprophylaxis with broad-spectrum antibiotics and a low-molecular-weight heparin were administered to all patients. All the patients received a typical TKA physiotherapy protocol when discharged. The final assessment of the study took place in August and September 2017 when failures and complications that had occurred were gathered and analyzed. The final assessment was made in a conference of two orthopaedics surgeons specializing in knee arthroplasty and a senior orthopaedics resident. Clinical evaluation for pain and function was performed using the Oxford Knee and Knee Society scores. The median preoperative Knee Society Knee Score was 39.7 ± 9.4 (range 10-70) and the median postoperative was 92.6 ± 7.5 (range 68 - 99) (p<0.001, t test).The median preoperative function score was 42.5 ± 16.6 (range 5-60) and the median postoperative function score was 72.9 ± 22.6 (range 33 – 98) (p<0.001, t test). Postoperatively, the Oxford Knee Score was 21.5 ± 4,9 which is considered very good. The median BMI of our patients was 32.5 ± 5.8 (range 21.5 – 43.4). The majority of them 59,52% (50 patients) were obese and only 9,52% of them were of normal weight. Mean preoperative range of motion improved from 98.85⁰ ± 12.03 (range 70º – 120º) to 105º ± 14.2 º (range 40º - 135º) (p<0.001, t test). All the patients but one acquired a fully-extended knee. In our series we did not manage to relate the BMI of our patients with their ROM./ did not establish any relation between our patients’ BMI and their ROM. Radiological assessment included weight bearing anteroposterior, lateral and tangential radiographs of the involved knee and the Knee Society Roentgenographic Evaluation System was used to record the component position, knee alignment and the prosthesis-bone interface. Any radiological change found during the follow-up was evaluated. Radiolucent lines at the tibial component–bone interface were observed οn anteroposterior radiographs early from the third year, in zones Ι and ΙV in 14 knees (13.2%). These radiolucent lines were no larger than 1mm and did not progress throughout the course of the study. On lateral radiographs, at the femoral component–bone interface, 2 knees (1.9%) with radiolucent lines not larger than 1mm were noted in zones I, II and III. At the last radiological follow-up, there was no evidence of loosening or significant radiolucent lines in any of the components. Complications occurred in 7 patients (6.6%). There were 6 revisions with a median time to reoperation of 11.2 years (range 5 - 14). From those, two patients suffered from patellofemoral pain and episodes of lateral subluxation and 1 patient from patellofemoral pain due to aseptic loosening of the initial patella implant 12 years later. A patellar replacement was performed with success in all cases. In conclusion, the use of Genesis I system provided a safe solution in the treatment of primary knee osteoarthritis in daily clinical practice. The results were encouraging and showed excellent survival rates, satisfactory functional outcome and low rate of mechanical failure and complications. Based on the international literature our study presents one of the longest follow–up for patients with Genesis I Total knee arthroplasty reaching 21.5 ± 2,97 (18-26) years. The average Kaplan Meier survivorship analysis was approximately 93.53% in 25 years. Our results are comparable with those of the literature concerning the particular prosthesis as well as those concerning similar prostheses. We believe that the greatest number of patients missed during the follow-up is due to the fact that they were of old age during the operation itself.

Degree

thesis:*
Grantor dc:publisher
University of Thessaly (UTH)
Year dc:date
2020

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Georgaklis, Vasilleios
  • Γεωργακλής, Βασίλειος

Subjects

dc:subject × 10

Rights

dc:rights
Statement dc:rights
  • BY
Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/46956

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Georgaklis, Vasilleios; Γεωργακλής, Βασίλειος. Μακροπρόθεσμα αποτελέσματα επιφανειακής ολικής αρθροπλαστικής γόνατος με ασύμμετρους κνημιαίους κονδύλους (GENESIS I). University of Thessaly (UTH), 2020. http://hdl.handle.net/10442/hedi/46956