National and Kapodistrian University of Athens
Εκτίμηση της συμβολής της αστικής μορφολογίας και λειτουργίας στο αστικό θερμικό περιβάλλον με την ανάπτυξη προηγμένων τεχνικών δορυφορικής τηλεπισκόπησης
Abstract
dc:descriptionIn this PhD thesis, a multifaceted study of the thermal environment of Athens was conducted. The motivation of the research work was to assess the influence of urban form and function on the urban thermal environment. The work was carried out primarily by applying and developing satellite remote sensing techniques, and to a lesser extent via Geographical Information Systems (GIS) methodologies and the implementation of numerical simulations. The current satellite systems do not have the synchronous spatial and temporal frequency which is needed in a detailed study of intra-urban variability. To this end, an improvement of the standard statistical downscaling methodologies was firstly developed, where LST is disaggregated based on its relationship with surface parameters. The downscaling was accomplished using multiple predictor variables, high resolution land cover-based emissivity values, and assessing various linear and non-linear regression algorithms. It was applied to sharpen the thermal observations of the Moderate Resolution Imaging Spectroradiometer (MODIS) from 1 km to 100 m. It was found that the suggested downscaling method —using the ridge regression downscaling algorithm— produced a robust, spatially sharpened LST, with an average Root Mean Square Error (RMSE) less than 2 K and a consistent better performance compared to the reference methods. At the next stage, the urban form, function, and energy fluxes were mapped at a high resolution (100 m) and subsequently combined in an urban heat exposure indicator. Utilizing a wide range of spatial data, a full description of the building environment was accomplished, as well as the derivation of the building height to road width ratio —urban canyon aspect ratio (H/W)— at street level. Next, using the downscaled satellite-derived LST from the first part of the study and meteorological observations, the sensible (QH) and latent heat flux (QE) were calculated, applying the “aerodynamic resistance” methodology. To assess the accuracy of the calculations, micrometeorological observations; an overall RMSE error of ∼45 Wm2 for QH and ∼15 Wm2 for QE was obtained. From the above turbulent fluxes, the Bowen ratio β = QH/QE was subsequently derived. To determine the anthropogenic heat flux (QF) a new algorithm was developed, combining the “bottom-up” and “top-down” methodologies, adapted to the available data for the study area. Particularly high anthropogenic heat emissions were found for the city center (QF > 100 W/m2).Subsequently, the above urban parameters (H/W, β και QF) together with the net heat storage (ΔQs) were integrated into the proposed Urban Heat Exposure (UHeatEx) indicator through Principal Component Analysis (PCA). The indicator outlined the diverging thermal quality of the different building blocks in Athens and thereby can be valuable to urban planning adaptation responses. Moreover, UHeatEx managed to highlight the city-specific features of the urban form and energy budget of the city, which to a great extent could not be captured by the classification of the Local Climate Zones (LCZ). At the final stage of the study, focus was shifted to the study of the integrated neighborhood-scale effect (1 km) on the urban thermal climate. Specifically, it was initially assessed how basic urban morphological parameters —the impervious fraction, the building fraction, and the building height— are interlinked to the surface temperature variations, as captured by a spaceborne sensor (MODIS). To promote the generalization of conclusions, in addition to Athens, 24 additional European cities were examined. The statistical analysis showed that the closely spaced and high-rise buildings have generally a weak positive or even a negative relation to LST in daytime and a strong positive effect at night. This finding was significantly pronounced for Athens, where further urban parameters were also evaluated and the results were linked to the LCZs classes. Next, urban form and function of Athens were incorporated in the WRF model to study its predicting ability of the thermal environment. Using WRF along with a modified urban parameterization scheme (at a 1 km grid), results indicated that the prevailing intra-urban spatial patterns can be reproduced in the simulations, regarding the surface temperature (RMSE ∼2.4 K) and the near-surface air temperature (RMSE ∼1.7 K).
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2020
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Agathangelidis, Ilias
- Αγαθαγγελίδης, Ηλίας
Subjects
dc:subject × 22- Δορυφορική τηλεπισκόπηση
- Επιφανειακή θερμοκρασία
- Υποκλιμάκωση
- Αστική μορφολογία
- Αστικό θερμικό περιβάλλον
- Αστικές ροές ενέργειας
- Τοπικές κλιματικές ζώνες
- Αστικός σχεδιασμός
- Satellite remote sensing
- Land surface temperature
- Downscaling
- Urban form
- Urban thermal environment
- Urban energy fluxes
- Local climate zones
- Urban planning
- Φυσικές Επιστήμες
- Φυσική
- Γεωεπιστήμες και Επιστήμες Περιβάλλοντος
- Natural Sciences
- Physical Sciences
- Earth and Related Environmental Sciences
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/47082