The present doctoral dissertation investigates the behavior of rehabilitated and strengthened external RC beam-column joints under cyclic loading. The specimens were designed according to Euro-code specifications. The study of repairing and strengthening techniques of the RC elements damaged during earthquake excitations constitutes a research field of vital importance for seismic prone regions around the globe. Modern regulations introduce an innovative seismic design of structures, whose application directs the damage and the creation of plastic hinges to occur within the beams so that the columns and the joints remain intact. This thesis focuses on the development of practical knowledge, as well as on the experimental study and investigation of the reliability of response prediction of full scale external RC beam-column joints. In order to investigate the behavior of the strengthened joints, three series of experiments with full-scale (1:1) external beam-column joint, under cyclic loading, were performed. In the first set of experiments, the rehabilitation of damaged Reinforced Concrete (RC) beam-column joints with C-FRP sheets was investigated. The joints suffered minor to moderate damage. The results demonstrated that the described technique is an effective method for rehabilitation. The conclusions are based on the observation that retrofitted specimens exhibited a load capacity and stiffness level more or less similar to those of the original intact beams.In the second series of experiments, the effectiveness of the external application of C-FRP cords on the surface of exteriorly reinforced concrete beam-column connections is investigated as rehabilitation and strengthening technique. The technique seems to be an effective method with easy application. The conclusions are based on the observation that the repaired specimens compared to the non-repaired specimens showed much greater load bearing-capacity and stiffness.In the third series of experiments, the use X-type reinforcement, either as steel cross inclined bars or alternatively as C-FRP cords used externally for strengthening, as the main shear reinforcement of external beam-column joint was investigated and compared with original specimens. The test data indicated that the response of strengthened specimens was improved in comparison with the control specimen. Finally, the use of additional bars as transverse reinforcement in the joint area, consisting of four longitudinal steel bars of Ø10 mm in diameter, was investigated. The effectiveness of these additional bars as a shear reinforcement on the overall seismic performance of the tested joint was examined. In general, the external joint with the additional bars in comparison with the control specimen without stirrups, exhibited similar values of load capacity in most of the loading cycles and almost the same values of hysteretic energy dissipation and stiffness degradation, practically in the entire loading sequence, while at higher deformation cycles were slightly increased and is likely to increase significantly with better reinforcement anchoring.

Degree

thesis:*
Grantor dc:publisher
Democritus University of Thrace (DUTH)
Year dc:date
2020

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Golias, Emmanuil
  • Γκόλιας, Εμμανουήλ

Subjects

dc:subject × 12

Rights

dc:rights
Statement dc:rights
  • BY_NC_ND
Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/47225

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Golias, Emmanuil; Γκόλιας, Εμμανουήλ. Διερεύνηση τεχνικών αποκατάστασης εξωτερικών κόμβων ωπλισμένου σκυροδέματος με συνθετικά υλικά. Democritus University of Thrace (DUTH), 2020. http://hdl.handle.net/10442/hedi/47225