University of Thessaly (UTH)
Investigation of the effect of vegetation and green infrastructures on outdoor bioclimatology: the case study of the environment of urban school buildings
Abstract
dc:descriptionThe aim of the present Doctoral Thesis is to study quantitatively and qualitatively the thermal uptake and the corresponding thermal stress on humans in urban open spaces with application to the environment of school buildings and to make proposals for schoolyard re-designing, mainly using planting elements to improve their bioclimatology of outdoor spaces. The school yards of various educational ranges are open spaces of great interest, as school-age children spend there a great deal of their time during the school day. In the densely populated cities of Greece, school yards are usually surrounded by dense and tall buildings, the surface covering is designed using materials with very high heat capacity such as asphalt, cement, bricks and slabs, shading systems usually do not exist, while planting elements are limited and usually distributed perimetrically, as the courtyard area is occupied exclusively by sports grounds, resulting in heavy thermal stress for children from April to November especially in warm or Mediterranean climatic climates. The main objectives of this paper were: 1) to investigate the biophysical environment created by the existing construction of schoolyards. 2) to look for methods that will improve the microclimate of school yards using mainly green elements above and around school buildings and 3) propose ways to redesign schoolyards in order to improve thermal uptake and thermal stress conditions in humans. Quantification of human thermal comfort is done with thermophysiological indices, most important of which is Physiologically Equivalent Temperature (PET). For calculating the PET index, the air temperature, relative air humidity, air velocity and Mean Radiant Temperature (Tmrt) are measured or simulated. Tmrt is determined by the short- and longwave flux densities from the three-dimensional environment of the human being, namely from vertical incident solar radiation, ground-reflected radiation, and horizontal circumferential radiation. In the 1st part of the thesis the human thermal uptake and the corresponding thermal stress conditions were studied in 6 school yards and the surrounding area of a university building of the city of Volos, with different spatial layout, orientation, extent, number and type of construction, soil cover materials and extent of planting, number and type of trees and planting arrangement. This section presents the results of the assessment of the thermal comfort conditions in two schools in Volos, the 1-2 Elementary School of Nea Ionia and the 23rd Primary School of Volos. The measurements took place during sunny days from April to October around the solar noon on the solar radiation plate, so that the meteorological conditions at the above time can be considered as constant. The meteorological factors (air velocity, air temperature, relative air humidity and solar radiation) were measured at characteristic points of the courtyard, the thermal uptake was calculated by calculating the mean radiant temperature and the thermal stress by calculating the thermophysiological PET index (oC) and Cluster analysis was applied which revealed microclimatically homogeneous points. The results of the spatial distribution of the parameters were presented on corresponding maps.25Analysis of the observations data showed that direct incident solar radiation was the determinant factor that affected the thermal uptake and thermal stress conditions in the two schools. The more exposed was an area in direct sunlight, the more intense the thermal stress was. Direct exposure to solar radiation has resulted in a high heat input from the sun and elevated mean radiant temperatures. At these points, thermal sensation reaches the extremes of extreme thermal strain on the PET scale. At places exposed to the sun on surfaces with materials with high reflectivity, thermal stress was further increased due to the high radiation-reflected radiation that increased the thermal load and the mean radiant temperature. Finally, the group of sun-exposed sites but at high wind speeds showed a 3.7 to 5 ° C decrease in the PET scale for each 1m / s increase in wind speed. Conversely, thermal sensation was clearly better in shaded areas, due to the significant reduction of incident radiation. Thus the trees, apart from their aesthetic value, offer significant microclimate advantages. The analysis of the results showed that the trees achieved a reduction of incident radiation reaching up to 94% depending on the increase of the crown density, the increase in the size of the crown, the reduction of the distance between the crown and the ground, the combined shading of different sub-layers of foliage and increased planting density in a row. The significant reduction in incident radiation under the trees resulted in a significant improvement in thermal sensation, with a mean radiant temperature drop of up to -56%, while average PET values reached up to -37%. At the same time, the range of harmful UV that reaches pedestrian level decreased by up to 92%. In the 2nd part, the effect on the microclimate conditions and on the thermal comfort conditions of architectural interventions in the building envelope including elements of vegetation was studied. The aim was to evaluate the parameters of the structures that could mitigate the thermal stress conditions near the building environment. The hydroponic pergola and the vertical hydroponic wall, which are the main points of interest in this second part, have the advantage compared to conventional shading systems, they use almost zero space in the ground, while contributing to the increase in green, they introduce the idea of planting outside of natural soil, and give the landscape architect a field of creativity in design, as different construction solutions can be synthesized to create the end result. To assess the effect on the microclimate of the hydroponic pergola and the hydroponic green wall, corresponding real-scale constructions were installed on the campus of the Technological Educational Institute of Epirus in Kostakioi, Arta. A number of parameters were continuously recorded on the patio, the green wall, and outside the atrium used as meteorological reference data. The experimental data was then used to evaluate the numerical simulation results of the recent version of the ENVI-met microclimate model, a microclimate simulation system based on Computational Fluid Dynamics (CFD) and principles of thermodynamics. The results showed very good agreement between measured and simulated values. The model was then used to predict the effects of different design scenarios on corresponding structures at air temperature (Tair), relative air humidity (RH) and average radiation temperature (Tmrt). The outputs of these parameters were used as input data in the RayMan pro (V 2.1) model for estimating the thermophysiological index PET. Design scenarios included different percentages of the atrium covered with pergola, or different heights of green walls and plants of different foliage density. From the study of the different scenarios on the patio during the day, there was a significant effect of the planted pergola on thermal intake when the patio is exposed to full sunlight. The simulated Tmrt values in the center of the atrium showed that in the case of the empty atrium Tmrt displayed high values (approximately 60 ° C) between 9:00 and 14:00 due to the effect of solar radiation reaching the center of the patio, while the rest of the day the surrounding buildings shaded the center of the patio. Compared to the absence of pergola in the atrium, covering 100% of the trellis pergola surface, the Tmrt and PET values decreased during the warmest part of the day by 29.4 ° C and 17.9 ° C respectively.Covering the surrounding walls inside the atrium with a green wall there was no significant effect on the microclimate on the patio compared to the case with empty walls. When 50% of the patio area was covered with a planted pergola and the surrounding walls were covered with a 2 m green wall, the average PET reduction was higher. The spatial distribution of Tmrt at various time intervals during the day and the absolute differences in Tmrt values compared to the empty atrium showed significant differences between the two cases for all study periods. The average absolute differences in Tmrt values observed in the atrium area shaded by the pergolas around 12:00 were 20.9 ° C, while the Tmrt's reduction in the atrium was periodic following the sun's movement and seasonal nature accordingly with the height of the sun over time. The green wall exposed in the south orientation does not seem to affect the thermal intake in front of the green wall. Tmrt and PET were also only slightly reduced due to the planted wall. The spatial analysis in front of the empty wall and the green wall showed that at a distance of more than 1 meter from the green wall, the differences in the observed Tmrt were eliminated. Although air temperature values were not significantly affected by the presence of the green wall, the most significant effect of the green wall was the reduction of the solar radiation behind the green wall, which led to a corresponding reduction in Tmrt. Behind the wall Tmrt was reduced by about 31 ° C throughout the sun exposure period. This reduction resulted in a significant decrease (about 8 ° C) in the building's surface temperature behind the green wall and then in the reduction of the building's energy load.Finally, in 3rd part, a study of the impact on the microclimate and the conditions of human thermal comfort of the bioclimatic redesign of the school yard landscape was made with simulations with the ENVImet (V4.0) microclimate simulation model, which included mainly the planting of trees and green shapes in the schoolyard. Initially, the recent version of the ENVImet (V4.0) microclimate simulation model was used, using experimental measurements and after its successful evaluation, the model was used to assess different design suggestions to improve thermal comfort conditions, comparing with the original state. The simulation of the existing yard state showed that the values of the thermophysiological PET index (oC) were within the range of the thermal sensation of the extreme thermal strain (> 41 ° C) from the early morning, while at midday 80.5% school courtyard was within the scope of the above category. With the implementation of the redesign proposal, 69.9% of the area of the courtyard area improved by two or three grades of the PET scale, contributing to the improvement of the microclimate in 82% of the total area of the yard. The stem of the trees reduced the direct incident radiation by more than 90%, decreased the mean radiant temperature (Tmrt) and the PET index to 31 ° C and 19 ° C respectively and the surface soil temperatures in wet grass and hard surfaces above 20 ° C and 14 ° C respectively.The present study has shown that the existing design of urban school yards creates conditions of intense thermal pollution, a situation that will become even more intense in the near future due to city overheating and evolving climate change. The feeling of this study remains that the open design of such spaces promotes thermal pollution, while the presence of predominantly shade trees provides thermal benefits. Thus, incorporating an effective bioclimatic design into school yards based on local climatic conditions can reduce exposure and thus protect children from the direct and cumulative consequences of different environmental burdens. Finally, an attempt of this study was to evaluate the ENVI-met microclimate model with the prospect of using numerical simulation as a promising perspective for extracting accurate results for the timely detection of different designer visions of architectural landscapes in microclimate and human thermal comfort and use the results in designing outdoor spaces with the best possible bioclimatic results. Finally, the ENVI-met (V4.x), enriched with new features, can provide reliable predictions of microclimate and thermal uptake parameters in a complex urban environment, providing accurate meteorological measurements near space study and detailed model settings.
Degree
thesis:*- Grantor dc:publisher
- University of Thessaly (UTH)
- Year dc:date
- 2018
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Antoniadis, Dimitrios
- Αντωνιάδης, Δημήτριος
Subjects
dc:subject × 10Rights
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/47283