Back to search

Democritus University of Thrace (DUTH)

Advanced process control in activated sludge systems

Abstract

dc:description

In this PhD thesis, advanced process control methods applying in two activated sludge systems were investigated. Both pilot-scale systems were operated under intermittently aerated and fed (IAF) conditions. In the first experimental period, a sedimentation tank was used in order to separate the activated sludge with the supernatant, while in a second experiment period, the settler was replaced with an ultrafiltration membrane module. Biological nitrogen removal was achieved using an alternating anoxic/aerobic cyclic process. For the first time, dynamic control of the nitrification and denitrification phase duration was implemented, depended on the variation of influent ammonium and nitrate nitrogen concentration, respectively, keeping all the other operating parameters at a constant level. The aerobic phase duration was dynamically controlled by in-situ on-line ammonium nitrogen ion selective electrodes (ISE) sensor, while the anoxic phase was dynamically controlled by in-situ on-line nitrate nitrogen ISE sensor. Subsequently, the on-line monitoring of pH profile during the aerobic phase was assessed in order to replace the high-cost NH4+-N sensor with the low-cost pH sensor. Correspondingly, the on-line monitoring of oxidation-reduction potential (ORP) profile during the anoxic phase was investigated in order to replace the high-cost NO3--N sensor with the low-cost ORP sensor. A new control strategy, based on oxygen uptake rate (OUR) determination deriving from dissolved oxygen (DO) concentration profile using an OUR biosensor, was investigated and proposed to supervise dynamically the duration of aeration period. Αir-flow control was achieved in order to save energy by applying a Proportional - Integral (PI) controller based on DO concentration measurement and as a next step, through a cascade control strategy consisted of both a PI-NH4 and a PI-DO controller based on the ammonium-N and DO concentration measurement. The filtration process control was achieved and optimized by on-line transmembrane pressure (TMP) monitoring in the submerged membrane bioreactor (MBR). The effects of critical flux, anoxic phase duration ratio and the biological parameters, such as extracellular polymeric substances (EPS) and soluble microbial products (SMPs) were investigated. Regarding the wastewater reuse, the quality of the MBR effluent characteristics was assessed according to the Greek legislation limits (JMD 145116/2011). The thesis is organized as follows. In Chapter 1, a general overview of the research work is presented. In Chapter 2, an introductive review of literature is described in brief. In Chapter 3, a real-time feedback control strategy is applied by the aid of ammonium-N and nitrate-N sensors in order to supervise and control the biological nitrogen removal processes in an intermittently aerated and fed (IAF) activated sludge (AS) system. In Chapter 4, an external submerged membrane bioreactor configuration and its operation mode are presented. On-line transmembrane pressure (TMP) monitoring and pattern is studied to estimate and control membrane fouling. Fouling prevention methods such as cleaning methods, alternate aeration method, flux operation below critical value etc. are implemented in the MBR system to improve the membrane filtration process, to reclaim the permeate flux and extend the membrane lifespan. Various real-time control strategies are described in this chapter to improve the biological processes performance with final efficient energy use. Assessment of pH and oxidation-reduction potential (ORP) parameters through bending points detection and their first derivatives for achieving real-time, dynamic control of nitrification and denitrification are presented. Development of a PI-DO control strategy and an advanced control strategy through cascade control (including a PI-DO and a PI-NH4 controller) structure are studied to improve the aerobic biological processes. Oxygen uptake rate (OUR) parameter is determined to control the aeration period and two control structures are proposed for their integrating on the control system. MBR system performance included reclamation and reuse aimed urban use is estimated, some disinfection methods (U/V, chlorination) are applied in the effluent stream, whereas E. coli and total coliforms enumerated and NTU value measured in the treated discharge effluent. In Chapter 5, conclusions, the innovation of PhD thesis and several recommendations for future research are given. In Chapter 6, scientific references are presented and at the end of PhD work in Chapter 7, published papers with impact factor, supplementary figures, flowcharts and PLC program codes are given as Appendices.

Degree

thesis:*
Grantor dc:publisher
Democritus University of Thrace (DUTH)
Year dc:date
2020

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Azis, Konstantinos
  • Αζής, Κωνσταντίνος

Subjects

dc:subject × 30

Rights

Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/47358

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Azis, Konstantinos; Αζής, Κωνσταντίνος. Advanced process control in activated sludge systems. Democritus University of Thrace (DUTH), 2020. http://hdl.handle.net/10442/hedi/47358