University of Thessaly (UTH)
Μελέτη του κινδύνου εμφάνισης αιματογενούς λοίμωξης σε διαφόρων τύπων μεταλλικά εμφυτεύματα: πειραματική μελέτη σε κονίκλους
Abstract
dc:descriptionIntroduction: Periprosthetic joint infection (PJI) is one of the most devastating and in some cases even life threatening complications following total joint arthroplasty (TJA) with rates varying between 0.3–3% after primary total hip arthroplasty (THA) and 0.5–1.9% after primary total knee arthroplasty (TKA). The pathogenesis of orthopaedic implant-related infections is multi-factorial. Several factors, related to the patient, the implant, the surgical technique and the operating theatre environment are associated with the development of PJI. A number of implant-related factors, such as the size and shape of the implant, the technique and stability of fixation, the use of cement, the surface characteristics of the implant and the type of alloy and its biocompatibility can influence susceptibility to local infection. The ideal alloy for implantation should have favorable adhesion characteristics to reduce biofilm formation and enhance normal tissue reaction, have minimal corrosion ability and do not contain allergenic properties. Currently, porous surfaces with cobalt-chromium and titanium are widely used. The addition of a layer of calcium phosphate, such as hydroxyapatite or triphosphate enhances the surface osseointegration. According to Gristina's theory (“the race for the surface”), rapid tissue integration with a biologically active material (such as tantalum, hydroxyapatite and cancellous titanium) could result in a lower bacterial colonization and biofilm formation compared to other coatings such as titanium. Implant-related infections are categorized in two clinical entities, based on their pathogenicity. Direct postoperative infections, which are usually caused during surgery by direct contamination of the wound, and late postoperative infections, in which the first symptoms appear later, in variable timelines after surgery. It is usually the result of bacteremia and subsequent spread of bacteria. Nowadays, experimental models have been established and led to innovative therapies for fracture healing and the use of new osteosynthesis materials. A reliable experimental model of periprosthetic infections will lead to a better understanding of the pathogenesis and pathophysiology of these infections and most likely to new methods of prevention and treatment. However, there is still no ideal and widely acceptable experimental model for acute periprosthetic infections. In our laboratory, a validated and reliable experimental model has been established which was used in our study. The working hypothesis of our experimental study was that metal implants of different materials, including modern three-dimensional metal structures, used for cementless implantation, are less vulnerable to the development of infection. Materials and Methods: 50 male, skeletally mature (>3months), New Zealand white rabbits were used in this experimental study. 50 Cylinders of given dimensions (length: 40mm, diameter: 3.5mm) were used for implantation. Animals were randomly divided into 5 study groups consisting of 10 animals each. Smooth titanium (ST) rods were implanted in group A, rough, grit blasted (GB) titanium rods in group B, hydroxyapatite (HA) coated titanium rods in group C, trabecular metal (T) rods in group D and cancellous titanium (CT) rods in group E. An inoculum of standardized CA-MRSA strain - MLST-80 PVL+ clone of given concentration (3 × 108 cfu/ml) was given. The concentration of 3 × 108 cfu/ml was standardized and validated by our institution’s animal model and has proved adequate in developing implant-related infection without causing severe systematic reactions or death.All animals underwent a 2-stage surgical procedure in their right leg, under general anesthesia and sterile conditions. During the first stage, the medullary canal was opened with an awl, and the rods were “press fit” implanted in the proximal tibial metaphysis and diaphysis. Four weeks later, a longitudinal incision was made over the medial surface of the femur in order to gain access to the femoral artery and vein. The femoral artery was identified and with the use of a 26-gauge catheter, a 1 ml suspension of inoculum of the standardized bacteria was injected into the femoral artery of all animals of groups B, C, D and E. In group A, 1 ml of sterile saline was injected in a similar way (control group). Subjects were euthanized 8 weeks after the first procedure and samples were harvested for pull out tests, conventional and PCR cultures, and histopathology study. Results: Local infection was observed in 6 animals: 3 in Group B; 1 in Group C, 1 in Group D, and 1 in Group E. Statistically significant changes were found when Group B (GB titanium) was compared to other groups. 2 specimens in Group B (grit-blasted titanium) were found to have interface lucent lines indicating septic loosening. In the pull-out tests, the interface separation load was statistically significantly higher (p <0.05) in the hydroxyapatite-coated group (group C) compared to the other groups, while statistically significant differences were found between Groups D and E (Tantalum and Cancellous Titanium) with those of Group B (GB titanium) and with the control group (group A) (p <0.05). The number of the specimens (conventional cultures and PCR studies) contaminated by the standardized pathogen was as follows: Group A: 0/10, Group B: 7/10, Group C: 6/10, Group D; 5/10, and Group E: 5/10. Comparing the number of colony form units isolated from the implant samples, Group B (GB titanium) showed statistically significantly higher values (Mann-Whitney test) compared to Group C (p = 0.044), Group D (p = 0.040) and Group E (p = 0.038). Based on the semi-quantitative histopathological score, the differences between the samples were not enough to achieve a statistically significant difference. Conclusion: Modern cementless implants (trabecular metal and cancellous titanium) show a lower risk of implant contamination and late clinical haematogenous infection.
Degree
thesis:*- Grantor dc:publisher
- University of Thessaly (UTH)
- Year dc:date
- 2020
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Komnos, Georgios
- Κομνός, Γεώργιος
Subjects
dc:subject × 7Rights
dc:rights- Statement dc:rights
-
- BY
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/47616