Aristotle University Of Thessaloniki (AUTH)
Συγκριτική μελέτη της κεντρικής αρτηριακής πίεσης της αρτηριακής σκληρίας και της ενδοθηλιακής λειτουργίας ασθενών υπό περιτοναϊκή κάθαρση και αιμοκάθαρση
Abstract
dc:descriptionHypertension, high blood pressure variability (BPV) and increased ambulatory pulse wave velocity (PWV) have been shown to be associated with increased cardiovascular events and death in hemodialysis (HD) patients. Comparative data on ambulatory blood pressure (BP) profile of peritoneal dialysis (PD) and HD are scarce, while no study has reported data on short-term BPV in PD patients or has compared the ambulatory course of central hemodynamics and PWV in these patients. This study also examined skin microcirculation using the novel method for assessment of endothelial function Laser Speckle Contrast Imaging (LSCI), as well as lung congestion assessed by lung ultrasound and chamber dimensions and systolic and diastolic performance of left and right ventricle. In the analysis of ambulatory peripheral BP profile and BPV parameters, 38 PD patients were matched with 76 HD patients (for age, gender and dialysis-vintage) and with 38 patients with chronic kidney disease (CKD) stage 2-4 (for age and gender). Patients under PD and HD underwent 48hour and CKD patients 24hour ambulatory BP monitoring with the oscillometric Mobil-O-Graph device. For the analysis of central hemodynamics, 38 patients under PD were matched with 76 patients under HD in a 1:2 ratio, as discussed above. For the study of endothelial function, 38 PD patients were matched in a 1:1 ratio with 38 HD patients and 38 controls. Finally 38 patients under PD and their matched 38 patients under HD were assessed by lung and heart ultrasound. During all periods studied, peripheral systolic BP (SBP) and diastolic BP (DBP) levels were numerically higher but not statistically different in PD than in HD patients and were significantly higher in PD or HD compared with predialysis CKD (PD:138.4±21.0; HD:133.8±15.5; CKD:125.5±13.4 mmHg, p=0.003), a difference evident also during daytime and night-time periods. Repeated-measurements analysis showed no effect of dialysis modality on ambulatory BP during all periods studied. All BPV indexes studied were similar between PD and HD patients and higher than CKD individuals (1st 24hour systolic ARV: PD:11.9±3.2; HD:11.2±3.5; CKD:9.8±2.5 mmHg, p=0.016). Over the total 48-hour period, no significant differences were observed between PD and HD patients in mean levels of central SBP, DBP, PP, AP, AIx, AIx(75) and PWV. However, PD patients had numerically higher levels than HD patients in all the above parameters during all periods studied and especially during the 1st 24-hour. Moreover, patients under PD and HD displayed different trajectories in all the above parameters over the course of the recording: in PD patients no differences were noted in central SBP (125.0±19.2 vs 126.0±17.8 mmHg, p=0.25), DBP, PP, AP, AIx(75) and PWV (9.5±2.1 vs 9.6±2.1 m/sec, p=0.27) from the 1st to the 2nd 24-hour period of the recording, while HD patients showed significant increases in all these parameters (SBP: 119.5±14.4 vs 124.6±15.0 mmHg, p<0.001; PWV: 9.1±1.8 vs 9.3±1.8 m/sec, p<0.001). Regarding the post-occlusive vascular response, the proportional increase from baseline-to-peak perfusion (PD: 149±125; HD: 133±66; controls: 187±61 %, p=0.001) and baseline-to-peak cutaneous vascular conductance (p=0.001) was significantly lower in in patients under PD and HD compared to controls. The US-B lines score did not differ between the two dialysis modalities [PD: 3.0 (2.0–6.3), HD: 4.0 (2.0–8.0) US-B lines, p=0.623]. Systolic volume (SV) and cardiac output (CO) were found to be lower in patients under PD compared to those under HD (p=0.030 and p=0.036 respectively). Finally TRV max and RVSP were found to be significantly higher in PD patients (p=0.022 and p=0.009). A significantly higher incidence of mitral valve regurgitation was also shown in patients under PD compared to those under HD (39.5% vs 10.5%, respectively, p=0.004). Average BP levels and BPV indices are similar between PD and HD patients and higher compared to CKD counterparts. Central BP, wave reflection indices and PWV during a 48hour recording are steady in PD but gradually increase in HD patients. Patients under PD and HD have similarly impaired endothelial function of skin microcirculation and similar degree of lung congestion.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2020
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Alexandrou, Maria-Eleni
- Αλεξάνδρου, Μαρία-Ελένη
Subjects
dc:subject × 12- Περιπατητική καταγραφή αρτηριακής πίεσης
- Αρτηριακή σκληρία
- Ενδοθηλιακή δυσλειτουργία
- Xρόνια νεφρική νόσος τελικού σταδίου
- Ambulatory blood pressure monitoring
- Arterial stiffness
- Endothelial dysfunction
- End-stage renal disease
- Ιατρική και Επιστήμες Υγείας
- Κλινική Ιατρική
- Medical and Health Sciences
- Clinical Medicine
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/47910