National Technical University of Athens (NTUA)
Ανάπτυξη νανοϋλικών σε πορώδη μέσα για την επεξεργασία ρυπασμένων νερών
Abstract
dc:descriptionElemental iron (ZVI) is an efficient reagent for a wide range of contaminants, organic and inorganic, because it combines several mechanisms of detoxification, such as reduction, adsorption or even Fenton type oxidative strength. At the nanoscale size, its efficiency is highly enhanced, due to the small particle size, large specific surface area and high reactivity. However, the direct use of ZVI nanoparticles (nZVI) for wastewater or contaminated groundwater treatment must overcome several constraints, which limit the applicability of this technology, such as difficulties to separate the exhausted nanoparticles from the purified aqueous phase, the low mobility in the porous aquifer and concerns about ecotoxicity of the nanoparticles in case of accidental release in the environment. On the other hand, the immediate application of nZVI suspensions for the treatment of contaminated water in stirring reactors demonstrates the significant problem of separating clean water from depleted nanoparticles. The main options under investigation to face this problem are the attachment of nZVI on the surface of a porous material. The aim of the present PhD thesis is the development of innovative nanomaterials that combines the high reactivity of nZVI, and especially its effectiveness about a wide range of inorganic and organic pollutants, along with the advantages of an easier handling, such as the utilization of the new composite material for the treatment of contaminated waters under flow conditions through a packed bed. In the framework of this PhD thesis, we have investigated the possibility to incorporate the ZVI nanoparticles in the matrix of Cationic Exchange (CE) resins. Research on this issue is very limited and in all previous efforts the reduction of adsorbed iron in the porous material was carried out using NaBH4. As a green alternative to the borohydride variant, we have decided to use polyphenols for the reduction step.The work was organized in the following phases: 1. Synthesis and characterization of the nanoiron loaded resin (R-nFe) using two types of CE resins, a gel-type and a macroreticular resin. 2. Evaluation of R-nFe capacity to remove Cr(VI) by conducting batch tests and detailed kinetic study under agitated conditions. 3. Development of a mathematical mechanistic model in order to describe the kinetics of Cr(VI) removal taking into consideration all the physical and chemical processes involved in the system under investigation. 4. Evaluation of the performance of the nanocomposite material under flow conditions by conducting column tests. Two categories of cationic resin beads, the gel type Dowex 50WX2 and the macroreticular type Amberlyst 15, were evaluated as porous support. The fixation of nZVI was obtained applying a two-step process. In the first step the resin granules were mixed with a FeCl3 solution to obtain the adsorption of Fe(III). Then the Fe(III) loaded resin (ReFe) was treated with polyphenol solutions to obtain the reduction of Fe(III) to the elemental state. Two polyphenol solutions were tested as reductants, i.e. green tea (GT) extract and gallic acid (GA). Green tea was found to be inefficient with the Dowex resin, due to the small size of pore diameters, 1.5-2.9 nm, in comparison with the relatively big size of the GT polyphenol molecules, estimated at about 3.3 nm. On the contrary gallic acid molecules with an estimated size of 1.3 nm, were able to reach adsorbed Fe(III) and reduce the cations to the elemental state. The reduction of adsorbed Fe(III) to Fe(0) by the natural polyphenols of GT was successful, when we used the macroreticular Amberlyst 15 as support, due to the high size of pores, 16-38 nm in this type of resin. The nanocomposite products were characterized by a variety of techniques including Scanning and Transmission Electron Microscopy, Atomic Force microscopy etc. In both R-nFe products, nanoiron was found to be homogenously dispersed inside the porous matrix. For the evaluation of the performance of this composite material, the removal of Cr(VI) from contaminated waters was studied. The maximum removal capacity measured during the tests was 650 mg/g Fe using Amberlyst as a substrate and 830 mg/g Fe using Dowex as a substrate. These results are included among the highest reported values, compared to available published data. The kinetics of Cr(VI) removal was studied in both R-nFe composites. All the experiments were carried out using a high stoichiometric excess with respect to Cr(VI) so that the amount of nanoiron can remain practically constant during the reaction. In this way, it was possible to study separately the effect of the presence of nZVI on the kinetics of reduction. The parameters which were investigated included the initial Cr(VI) concentration, the pH, the amount of the R-nFe and the concentration of nanoiron on the resin beads. It was found that chromate reduction follows a kinetic law of first order with respect to Cr(VI) and to the available amount of nZVI. In addition, the rate of the reaction decreases when the pH increases. The values of the kinetic constant for both types of resins was similar and ranged between 0.5·10-3 and 8·10-3 min-1 per mmol/L of available nZVI when the pH varied from slightly alkaline (7.5-8.5) to acidic (2.7-3.5) respectively. To obtain a better understanding of the underlying phenomena, a mechanistic mathematical model was developed, taking into consideration the following interrelated processes: (i) the diffusion of chromates from the surface to the center of the spherical beads, through the network of pores; (ii) the chemical reaction between the contaminant and the surface of iron nanoparticles, which were considered to be uniformly dispersed in the pore network; and (iii) the depletion of iron nanoparticles according to the shrinking core model. The main parameters of the model was the effective diffusion coefficient, (m2/s) and the intrinsic kinetic constant (m/s) per surface unit of nZVI. An initial set of experiments was used to obtain the values of these parameters by fitting model calculations to the experimental data. Optimal fitting was obtain with =0.86x10-9m2·s-1 and = 1.73x10-8 m·s-1. These values of and were used to predict the kinetics under different experimental conditions. Experimental and calculated data were very close, with deviations ranging between 3-5%, confirming the validity and predictive strength of the model. The performance of the process under flow conditions was evaluated by conducting column tests. An initial set of experiments indicated that a prerequisite for the effective operation of the column was to maintain a similar ionic strength of the aqueous phase inside the porosity of the grains and on the external porosity of the bed. This condition was achieved in a second cycle of tests under flow conditions, using an inert electrolyte. The column in the second cycle of experiments was maintained in operation for the treatment of an amount of solution equivalent to 680 bed volumes (BV) and its effectiveness was evaluated as a function of the residence time of the solution in the bed. The results suggest that the column operates efficiently, with complete removal of Cr(VI) from 5200 μg/L to levels below detection limit (<6 μg/L), when the residence time is more than 3.3 min. Also, when the feeding solution was spiked with both Cr(VI) and Ni, the effluents were free from the two elements, indicating that the nanocomposite material can be equally efficient in the case of mixed contamination. Based on the results of column tests, indicative calculations were performed to determine the required dimensions of a water treatment installation for two characteristic cases of pollution with hexavalent chromium, one case of high pollution (5000 μg/L) and one case of lower pollution (500 μg/L). Assuming a flow rate of 20 L/min and a slightly acidic pH = 5 of treated waters, the minimum required bed volume was calculated to be about 130 liters in the case of low pollution and 260 liters in the case of high pollution. The kinetics of Cr(VI) removal decreases at higher pH values. For this reason, if the treated waters are alkaline, e.g. with pH=8, the required bed volume corresponds to 550 L and 1100 L, for cases of low and high pollution respectively. Based on a thorough review of available published data, it can be seen that the performance of the nanocomposite material prepared in the context of this thesis is comparable to the most effective commercial materials, as far as Cr(VI) removal is concerned. Compared to other products, its major advantages include the ability to remove simultaneously a variety of pollutants, such as Ni cations, but also other organic and inorganic pollutants, due to the multiple removal mechanisms of the incorporated nanoiron.
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2020
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Toli, Aikaterini
- Τόλη, Αικατερίνη
Subjects
dc:subject × 20- Νανοσύνθετο υλικό
- Εξασθενές χρώμιο Cr(VI)
- Νανοσωματίδια σιδήρου
- Ιοντοανταλλαγή
- Κατιονική ρητίνη
- Κινητικές αναγωγής
- Nanocomposite material
- Hexavalent chromium Cr(VI)
- Iron nanoparticles
- Ion exchange
- Cation exchange resin
- Reduction kinetics
- Φυσικές Επιστήμες
- Γεωεπιστήμες και Επιστήμες Περιβάλλοντος
- Επιστήμες Μηχανικού και Τεχνολογία
- Νανοτεχνολογία
- Natural Sciences
- Earth and Related Environmental Sciences
- Engineering and Technology
- Nano-Technology
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/48132