National and Kapodistrian University of Athens

Ανάπτυξη διαδικασιών και μεθόδων για τη ραδιοβιολογική μελέτη και τον ποιοτικό έλεγχο σύγχρονων τεχνικών ακτινοθεραπείας

Abstract

dc:description

Technological evolutions in medical imaging and radiation oncology have paved the way towards an increased application of Stereotactic Radiosurgery (SRS) techniques. Although the proven superiority in the clinical efficacy of SRS techniques compared to conventional ones, the dosimetric and geometric accuracy as well as the radiobiological mechanisms are crucial factors for the efficient and safe implementation of an SRS treatment. Therefore, quality assurance procedures and accurate radiobiological estimations play an important role in the clinical outcome. However, small field dosimetry in SRS involves a high level of uncertainties. Moreover, treatment’s total spatial errors stem from any link of the treatment chain and should be thoroughly evaluated. Another important factor is the radiobiological effectiveness of the prescribed dose which depends on the dose level, dose rate, and the total treatment time. A theoretical background of SRS applications emphasizing on dosimetric and radiobiological principles is given in the first part of the thesis. The second part consists of SRS systems’ quality assurance related studies. Initially, Monte Carlo (MC) simulations were performed to calculate the "k" _("Q" _"msr" "," "Q" _"0" )^("f" _"msr" "," "f" _"ref" ) and "k" _("Q" _"clin" "," "Q" _"msr" )^("f" _"clin" "," "f" _"msr" ) correction factors required for precise absolute and relative dose measurements in the small fields of Gamma Knife (GK) SRS system. Correction factors were determined for an extensive range of ionization chambers and dosimetry diodes, a microDiamond detector, TLDs, and alanine pellets using a comprehensive MC model of the GK Perfexion unit. Calculations were performed for the Solid Water (SW) and Acrylonitrile Butadiene Styrene (ABS) plastic phantoms, as well as for a water phantom of the same geometry. Dosimetric effects causing by the presence of small air gaps between detectors’ surfaces and phantom inserts were evaluated for an indicative range of detectors through additional MC simulations. "k" _("Q" _"msr" "," "Q" _"0" )^("f" _"msr" "," "f" _"ref" ) values close to unity were calculated for the vast majority of ionization chambers, TLDs, and alanine pellets in water. Ionization chambers with large active volume and steel central electrode were associated with greater corrections up to 6%. Plastic phantom materials were found to affect absolute dose measurements by 0.6% and 2.4% for the SW and ABS, respectively, relative to water. MC calculations for the diode and microDiamond detectors resulted in lower than the unit "k" _("Q" _"clin" "," "Q" _"msr" )^("f" _"clin" "," "f" _"msr" ) correction factors, mainly due to the high physical density of their active volume as well as the presence of the extra-cameral materials. In contrast, "k" _("Q" _"clin" "," "Q" _"msr" )^("f" _"clin" "," "f" _"msr" ) values for ionization chambers were found larger than the unit, indicating underestimations of the measured dose depending on the field size (more significant for the 4 mm field) and the combination of competing phenomena related to the geometrical characteristics and the orientation of the chambers, as well as electron fluence perturbations. The presence of a 0.5 mm thick air gap at the frontal surface of the dosimetric diodes may significantly affect the Output Factors’ (OFs) measurements, up to 4.6% for the Razor diode. Following the MC simulations, correction factors for a set of ionization chambers suitable for absolute dose measurements in the GK reference field and corresponding output corrections factors for 2 chambers and 4 diodes were determined experimentally. The purpose of this study is to develop experimental dosimetry methods in GK and to verify the MC calculated correction factors. "k" _("Q" _"msr" "," "Q" _"0" )^("f" _"msr" "," "f" _"ref" ) correction factors were measured for the SW and ABS phantoms commonly used for GK reference dosimetry, while "k" _("Q" _"clin" "," "Q" _"msr" )^("f" _"clin" "," "f" _"msr" ) factors were determined only for the SW phantom. Reference dose quantities required for the calculations of the above correction factors were measured using TLDs, alanine pellets, and radiochromic films. Experimentally determined "k" _("Q" _"msr" "," "Q" _"0" )^("f" _"msr" "," "f" _"ref" ) values agree within uncertainties with the corresponding MC-calculated values corroborating the detectors’ orientation-dependence within the phantom. Corrections less than 1% were found for small-volume ionization chambers, reaching up to 5% for chambers with larger active volumes or steel central electrode. Measurements were also verified MC calculated "k" _("Q" _"clin" "," "Q" _"msr" )^("f" _"clin" "," "f" _"msr" ) correction factors, highlighting once again the expected underestimation of the ionization chambers and overestimation of the dosimetry diodes when used with small fields. OFs measurements in both clinical fields were in good agreement within uncertainties with corresponding MC-calculated values and the pre-stored values in the treatment planning system. To investigate the total spatial accuracy of an SRS application, the Total System Error (TSE) of a CK unit was estimated by performing End-to-End tests. A 3D polymer gel dosimetry based End-to-End procedure was implemented using a 3D-printed anthropomorphic head phantom derived from the computed tomography data of a real patient. A treatment plan for a multiple metastases case with spherical targets widely distributed within the brain was created. Phantom was irradiated utilizing the 6Dskull patient tracking method and scanned using a magnetic resonance imaging system for dose read-out. Following the necessary data analysis procedures, the TSE of a CK system was estimated ranging from 0.26 ± 0.08 mm up to 0.66 ± 0.07, demonstrating a spatial accuracy of the deposited dose distribution less than 1 mm even in targets lying up to 80 mm from the virtual isocenter. In the last part of this thesis, dose-rate and Biologically Effective Dose (BED) values were calculated for vestibular schwannomas cases treated in a CK SRS system. Voxel-based dose-rate mapping for a cohort of 25 patients was implemented. Calculations resulted in dose-rates greater than 2.5 Gy/min for the majority of the voxels and in a mean total treatment time of 21 min. Total treatment time was found to be directly related to the size of the targets, while decreasing approximately by 14% for an increase of the linear accelerator output rate from 800 to 1000 MU/min. Furthermore, a statistically significant positive correlation between dose-rate and field size was observed. Calculated BED values taking into account the involved time factors resulted in a mean value from all cases of 101 Gy2.47 for an 800 MU/min output rate. This value is 20% lower than the one resulting from the corresponding BED calculations that assume acute dose deposition, revealing a significant BED loss, especially in the periphery of the target, that may affect the treatment’s biological outcome. Finally, BED values were found to increase with a treatment time decrease or an output rate increase (in 1000 MU/min), while at the same time percentage BED loss decreases.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2020

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Zoros, Emmanouil
  • Ζώρος, Εμμανουήλ

Subjects

dc:subject × 22

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/48588

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Zoros, Emmanouil; Ζώρος, Εμμανουήλ. Ανάπτυξη διαδικασιών και μεθόδων για τη ραδιοβιολογική μελέτη και τον ποιοτικό έλεγχο σύγχρονων τεχνικών ακτινοθεραπείας. National and Kapodistrian University of Athens, 2020. http://hdl.handle.net/10442/hedi/48588