Back to search

University of Ioannina

Development of analytical methods based on sample preparation and liquid chromatography-high resolution mass spectrometry for the determination of emerging contaminants

Abstract

dc:description

A new class of contaminants has emerged an environmental issue, as a result of technology manufacturing or anthropogenic activities regarding medicine, agriculture, food, and domestic conveniences. The new class of contaminants the so-called ‘’emerging contaminants’’ (ECs) are discovered to have been released to the environment and pose potential threats to environmental ecosystems and human health and safety. They are commonly not regulated and can be detected in low or very low concentrations by analytical techniques, raising special concern due to their long-term adverse effects. These emerging contaminants include Pharmaceutical Active Compounds (PhACs), Personal Care products (PCPs), pesticides, industrial chemicals and some of them are released in the environment via excretion and metabolism. The main receptors for these compounds are the WWTPs which are not designed to efficient remove these contaminants at trace levels and eventually, treated effluents still contain ECs in considerable concentrations. Therefore, data concerning their existence is required. Detection of these contaminants in environmental matrices such as wastewater is particularly challenging because of the low detection limits required, the complex nature of the samples, and difficulty in separating these compounds from interferences. For this reason, rapid, inexpensive, efficient and environmentally friendly sample preparation techniques have been developed along with a sensitive selective chromatographic system coupled with orbitrap mass analyzer (UHPLC-LTQ Orbitrap MS), for the determination of selected Emerging Contaminants (ECs), namely sulfacetamide, sulfadiazine, olanzapine, sulfathiazole, sulfapyridine, trimethoprim, sulfamethizole, sulfamethazine, sulfamethoxy-pyridazine, sulfamethoxazole, risperidone, venlafaxine, sulfaquinoxaline, oxolinic acid, paroxetine, cyclobenzaprine, erythromycin, amitriptyline, fluoxetine, carbamazepine, clomipramine, acesulfame, saccharin, sucralose, aspartame, florfenicol, salicylic acid, indomethacin, gemfibrozil, mefenamic acid, triclosan and tolfenamic acid, in wastewater effluent. The sample preparation techniques involved in this study were: Magnetic Solid-Phase Extraction (MSPE), Fabric Phase Sorptive Extraction (FPSE) and Solid-Phase Extraction (SPE).Specifically, the high mass resolution capabilities of the Orbitrap MS were exploited for the determination of 33 emerging contaminants belonging to pharmaceutical active compounds (PhACs), personal care products (PCPs), artificial sweeteners (ASs), allowing facile discrimination between analytes and matrix. Operational parameters of the Orbitrap MS (ESI parameters, mass resolving power, AGC target, tube lens, injection time) were evaluated along with the chromatographic conditions (chromatographic column, mobile phase etc.) for the confirmation of analytes at trace concentration levels. Mass accuracy for target contaminants using this method was less than 5 ppm in both positive and negative ionization modes investigated.Magnetic solid Phase Extraction (MSPE) with the use of silica-based (C18) and graphene-based (mrGO) magnetic nanoparticles (MNPs) was developed, optimized and validated for the determination of 16 and 19 ECs respectively in effluent and tap water. Magnetic nanoparticles were successfully synthesized and characterized with XRD, SEM, FT-IR providing the desired morphological and structural characteristics. Analytical performance of the method was excellent providing good linearity with coefficients of determination (R2) greater than 0.99, high repeatability and reproducibility and recoveries ranged from 58.4% to 102.6% for both MSPEs. MSPEs employed with C18 and mrGO MNPs provided high sensitivity with minimum MDLs and MQLs up to 0.6 and 1.8ng/L, respectively. In addition, MSPE technique proved to be efficient for elimination of sample matrix.A novel FPSE protocol has been developed and optimized to follow the green analytical chemistry demands for the extraction and determination of 21 selected emerging contaminants in wastewater and tap water. FPSE was combined with UHPLC-MS-Orbitrap to take advantage the utilities of the new sample pretreatment for the enrichment of the analytes of interest and the powerful mass analyzer of Orbitrap. Fabric medium consisted of a fiber glass substrate and a sol-gel coating of PEG, was synthesized, characterized, and employed as an FPSE device. Under optimized conditions validation assays were followed for two aqueous matrices, tap water and effluent wastewater. FPSE exhibited excellent analytical characteristics in terms of linearity, intra-day, and inter-day precision for both tap water and effluent. MDLs and MQLs for effluent water ranged from 3.1-149.4 ng/L and 9.3-447.7 ng L/L, low enough considering the enrichment factor, but rather high for assessing an environmental monitoring survey in WWTPs. For this reason, a Solid-Phase Extraction (SPE) followed by UHPL-LTQ-Orbitrap-MS was applied for the determination of 33 ECs in effluent water. SPE was optimized and validated with excellent analytical characteristics including low MDLs and MQLs up to 0.3 ng/L and 1.0 ng/L, respectively. Afterwards, it was employed for the analysis of effluent waters collected during a one-year monitoring study from municipal and hospital WWTPs located in different cities of Greece, Ioannina and Amaliada. The analysis of the samples revealed the occurrence of 28 compounds of different therapeutic classes and chemical categories. The most abundant compounds in terms of mean concentrations were acesulfame (4862.5 ng/L), sucralose (993.8 ng/L) and salicylic acid (981.8 ng/L). Concentration occurrence, frequency of detection, temporal and seasonal variations were investigated and compared with relevant studies. Consumption patterns and explanations about the occurrence of emerging contaminants were estimated. Finally, the presence of target compounds was further confirmed with the association of fragment ions (MS/MS) and precursor ions providing high mass accuracy less than 5ppm.

Degree

thesis:*
Grantor dc:publisher
University of Ioannina
Year dc:date
2020

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Kalampoka, Maria
  • Καλαμπόκα, Μαρία

Subjects

dc:subject × 9

Rights

Language dc:language
eng

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/48589

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Kalampoka, Maria; Καλαμπόκα, Μαρία. Development of analytical methods based on sample preparation and liquid chromatography-high resolution mass spectrometry for the determination of emerging contaminants. University of Ioannina, 2020. http://hdl.handle.net/10442/hedi/48589