University of Patras
Υπολογιστική και πειραματική διερεύνηση διφασικής ροής σε παθητικό σύστημα διαχωρισμού με αγωγούς μικρής διαμέτρου και ενσωματωμένη διακλάδωση τύπου Τ διαφόρων προσανατολισμών και γεωμετρικών διαμορφώσεων
Abstract
dc:descriptionThe complexity characterizing in general the description of multiphase flow, and more specifically gas-liquid two-phase flow in conjunction with their wide range of applications, and the capability of T-junctions to act as partial phase separators either solely or in combination with conventional separators, dictated the objective of the present thesis. However, the separation that inevitably occurs at T-junctions results to an uneven split of the incoming mixture phases affecting both separation efficiency and downstream equipment, whereas it is depended on many parameters. Thus, the aim of the current work was to investigate the effect of the inclination angle adopted for the side arm of both regular and reduced T-junctions to important two-phase flow parameters such as phase separation, liquid carryover, mixture velocity, void fraction, total pressure, and pressure gradient. The outcomes of both two- and three-dimensional computational investigations revealed on the one hand the superior performance of the tilted at 30° side arm, which proved to be able to ensure a high and relatively stable separation performance despite the significant increment of air superficial velocity, on the other hand the decrement in separation efficiency for increasing water superficial velocity, especially at the vertical oriented T-junction. Now, the void fraction, and the mixture velocity upstream the junction showed to be irrespective of the adopted side arm inclination angle and/or of its diameter, whereas a higher void fraction value resulted in a greater separation efficiency. The almost identical void fraction values and mixture velocity upstream the T-junction, regardless of the adopted inclination angle of its side arm, led to identical values of total pressure as well, whereas the pressure gradient due to the presence of the junction was significantly greater than the corresponding one arose in the main arm of the separation system, for all test cases examined. In general, the results in case of reduced T-junctions indicated that separation systems already consisted of small diameter pipes, further decrement in side arm diameter did not improve the separation performance, on the contrary it deteriorated it. Finally, the comparison of the results extracted from the experimental and the computational investigation confirmed the quality of the latter as it was able to capture both the high and relatively stable separation performance occurred in experimental campaign, and the flow pattern developed in the main arm which corresponded to stratified or stratified-wavy flow pattern, whereas the corresponding comparison regarding the predictions of the void fraction values and frictional pressure drop by applying theoretical models demonstrated that none of them has a general applicability, and their use is depending on the required accuracy.
Degree
thesis:*- Grantor dc:publisher
- University of Patras
- Year dc:date
- 2020
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Makrygiannis, Georgios
- Μακρυγιάννης, Γεώργιος
Subjects
dc:subject × 20- Απόδοση διαχωρισμού
- Βαθμίδα πίεσης
- Διακλάδωση τύπου Τ
- Διαχωρισμός φάσεων
- Διφασική ροή αέρα-νερού
- Πειραματική διερεύνηση
- Υπολογιστική ρευστοδυναμική
- Air-water mixture
- Computational fluid dynamics
- Experimental investigation
- Phase split
- Pressure gradient
- Separation performance
- T-junction
- Επιστήμη Μηχανολόγου Μηχανικού
- Επιστήμες Μηχανικού και Τεχνολογία
- Μηχανολογία
- Mechanical Engineering
- Engineering and Technology
- Mechanics
Rights
dc:rights- Statement dc:rights
-
- BY_NC
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/48854