Back to search

University of Ioannina

Υστεροσκόπηση: η πορεία της ως μέθοδος διάγνωσης και θεραπείας και οι προοπτικές εξέλιξής της

Abstract

dc:description

Study Objective: Office hysteroscopy emerges over the years as the gold standard technique in assessing endometrial and endocervical pathology with consistent scientific evidence of high diagnostic accuracy. Design: A 20-year-retrospective study of diagnostic outpatient hysteroscopySetting: Endoscopic Unit, Department of Gynaecology, University Hospital of Ioannina, GreeceSample: 2675 patients underwent outpatient diagnostic hysteroscopy for common hysteroscopic indications. Interventions: Outpatient diagnostic hysteroscopy with no use of analgesia performing via vaginoscopic approach. Measurements and Main Results: Commonest hysteroscopic indications in all age groups was Abnormal Uterine Bleeding. Predictive characteristics of hysteroscopy in the diagnosis of various conditions were performed for those patients, that histology results were available (n=1529). Comparing the hysteroscopy findings with the histology results, the normal endometrium had a sensitivity of 60.9%, specificity of 92.1%, PPV of 79.07% and NPV 82.84%. Polyps had a sensitivity of 92.04%, specificity of 89.14%, PPV of 73.52% and NPV 97.16%. For fibroids, sensitivity and specificity were calculated at 98.55% and 100 % respectively, while PPV and NPV at 100% and 99.93%, respectively. For endometrial cancer the predictive characteristics were 87.5% and 99.74% for sensitivity and specificity, and 63.64% and 99.93% for PPV and NPV. Finally, hyperplasia had a sensitivity of 75.0%, specificity of 91.03%, PPV of 11.76% and NPV of 99.56%. Vaginoscopic office hysteroscopy is a simple, well-tolerated technique with low rates of failure (1,31%). The overall satisfaction of women undergoing the procedure is high. All patients received written information regarding the upcoming procedure and. No analgesia is needed in order to perform the intervention. Hysteroscopic features such as, stromal oedema, diffuse or focal hyperaemia, “strawberry effect”, micropolyposis and endometrial polyps are proposed by the international literature as suggestive of Chronic Endometritis (CE). All hysteroscopic features, alone and in combination were applied in 7 (seven) different subgroups of the sample: total sample, women in reproductive age, women with infertility issues/IVF screening, women with history of recurrent miscarriages, menopausal women, and women with hysteroscopic indication of Abnormal Uterine Bleeding (AUB), both or reproductive age and in menopause. From each case, endometrial samples were obtained and immunohistochemistry, identifying CD-138, was applied in order to diagnose CE. From a total of 2765 patients, 1444 women were found with at least one of the proposed hysteroscopic features mentioned above. Stromal oedema, focal or diffuse hyperaemia and “strawberry effect” in combination with micropolyposis demonstrated higher rates of diagnostic accuracy in the detection of CE compared to histologic confirmation in all groups applied. The main sonographic evidence of tamoxifen-related abnormalities were increased endometrial thickness, heterogeneity and evidence of endometrial masses. The overall diagnostic accuracy of transvaginal ultrasound (TVS) was estimated at 80.83% (CI95%,74.56% to 86.13%). More specifically, sensitivity, specificity, positive prognostic value (PPV) and negative prognostic value (NPV) were 86.07%, 71.83%, 84.00% and 75.00%, respectively. All sonographic and hysteroscopic findings were correlated with histologic results, the gold standard technique, in order to estimate the diagnostic accuracy of both approaches. According to our findings, hysteroscopic approach demonstrates higher diagnostic accuracy (96.37% (CI95%, 92.67% to 98.53%)) than the sonographic evaluation, when compared with histologic findings. The sensitivity, specificity, PPV and NPV of this method was estimated at 98.36%, 92.96%, 96.00% and 97.06%, respectively. Common hysteroscopic features in these cases were tamoxifen-related endometrial polyps and atrophy. Hysteroscopy was able to detect 136 out of 137 cases of congenital malformations with a false positive bicornuate uterus. Transvaginal sonography (TVS) showed moderate diagnostic accuracy accompanied by positive predictive value (PPV) at 79.79%, negative predictive value (NPV) at 99.17%, sensitivity at 79.79%, and finally specificity at 99.17%. Endometrial thickness assessed by TVS was found higher in cases of complete septate and bicornuate uteri. The incidence of congenital malformation within the total population was estimated at 5.12%. Overall TVS demonstrated diagnostic accuracy of 84.71%% compared to 97.38% of OHSC in the detection of endometrial pathology. Sensitivity, specificity, positive prognostic value (PPV) and negative prognostic value (NPV) of TVS detecting endometrial pathology were 84.05%%, 86.83%%, 95.32%% and 63.03%, respectively. The corresponding values for hysteroscopy were 98.9%, 95.14%, 98.47% and 93.96%, respectively. Diagnostic value of both techniques was estimated in 6 (six) additional subgroups: total sample with AUB, women of reproductive age, women of reproductive age with AUB, women of reproductive age with infertility issues, postmenopausal women and postmenopausal women suffering from postmenopausal bleeding (PMB). All values were calculated with regards to histologic findings as gold standard technique. All results were correlated with scientific evidence collected from the international literature. Conclusion: This is the largest retrospective study on office hysteroscopy in Greece to date. Our results demonstrate an efficient, well-accepted and safe technique rightfully declared as gold standard technique in the investigation of endocervical and endometrial pathology.

Degree

thesis:*
Grantor dc:publisher
University of Ioannina
Year dc:date
2020

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Tsonis, Orestis
  • Τσώνης, Ορέστης

Subjects

dc:subject × 16

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/48960

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Tsonis, Orestis; Τσώνης, Ορέστης. Υστεροσκόπηση: η πορεία της ως μέθοδος διάγνωσης και θεραπείας και οι προοπτικές εξέλιξής της. University of Ioannina, 2020. http://hdl.handle.net/10442/hedi/48960