National Technical University of Athens (NTUA)
Ανθεκτικότητα δοκών οπλισμένου σκυροδέματος υπό μόνιμη καμπτική φόρτιση
Abstract
dc:descriptionThe deterioration of the reliability of a concrete structure over time is the result of various mechanical, physical, chemical and biological processes, with the corrosion of reinforcement being the most serious problem of durability of reinforced concrete structures. For the past fifty years, the international scientific community has made tremendous efforts with laboratory research and experimental field studies to increase the corrosion resistance of concrete. The infestation of structures by the penetration of chlorides is a key problem in our country as it mainly concerns coastal structures that are affected by seawater. The subject of this dissertation was the study of methods of protection of reinforced concrete while investigating the influence of permanent bending load on the strength of a carrier. The compositions were prepared according to the latest concrete regulations and international standards and are as follows: conventional quality concrete C30/37, conventional concrete with corrosion inhibitor as an additive, conventional concrete with surface protection, fine aggregate concrete and self-compacting concrete. For the experimental part, 40 reinforced concrete beams of 5 different compositions were constructed and exposed to 2 different simulated environmental conditions at 3 different loading levels for a total period of 42 months. Their anti-corrosion behavior was determined by regular tests of the electrical resistance of concrete and the corrosion potential of the reinforced steel bars using copper sulfate as the reference electrode. In addition, their anti-corrosion behavior was determined by the following laboratory tests: water absorption test, water pressure permeability test, mercury penetration porosimetry, rapid chloride penetration test, accelerated carbonation test. The experimental results showed that the protection systems tested provide adequate protection to the reinforcement against corrosion compared to the reference specimens. Also, an inversely proportional relationship of the Water/Cement ratio of a composition with the ability to protect against corrosion was observed. Lower Water/Cement values (0.4 instead of 0.5) lead to better anti-corrosion behavior. Finally, it is observed that the corrosion rate of steel gradually increases with increase of the permanent load. The interaction of permanent loading with the corrosion of the reinforcement is a relationship that has not been thoroughly investigated as of this writing. This creates a need for further research so that the new reinforced concrete structures take all harmful factors into account and prove to be more durable over time.
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2020
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Karavokyros, Loukas
- Καραβοκυρός, Λουκάς
Subjects
dc:subject × 21- Ανθεκτικότητα σκυροδεμάτων
- Οπλισμένο σκυρόδεμα
- Διάβρωση
- Αναστολείς διάβρωσης
- Ενανθράκωση
- Χλωριόντα
- Ενισχυμένη δοκός
- Καμπτική αντοχή
- Concrete durability
- Corrosion
- Stress corrosion cracking
- Anticorrosive protection
- Concrete carbonation
- Chlorides
- Reinforced concrete
- Μηχανική Υλικών
- Επιστήμες Μηχανικού και Τεχνολογία
- Επιστήμη υλικών, χαρακτηρισμός και δοκιμές
- Materials Engineering
- Engineering and Technology
- Materials Science, Characterization and testing
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/48980