Back to search

Democritus University of Thrace (DUTH)

Αξιολόγηση των μεθόδων εκτίμησης της Υδρικής Κατάστασης ασθενών με Χρόνια Νεφρική Νόσο τελικού σταδίου που υποβάλλονται σε αιμοκάθαρση

Abstract

dc:description

Chronic overhydration is common in end-stage renal disease (ESRD) patients undergoing standard thrice-weekly hemodialysis (HD) and is involved in hypertension development in at least 80% of patients. Furthermore, chronic overhydration leads to an increased rate of cardiovascular events, which is the main cause of mortality in HD patients. However, underestimation of dry weight may lead to underhydration and subsequently to the development of intradialytic hypotension, the main reason for serious cardiovascular complications. The control of volume status can decrease many of these complications and prevent cardiovascular morbidity and mortality.Numerous studies have shown that diagnosis of over- and underhydration by clinical examination lacks sensitivity and specificity in contrast to sonographic determination of the diameter and collapse of the inferior vena cava.Methods such as Inferior Vena Cava Diameter (IVCD), Bioelectrical Impedance Analysis (BIA) and Continuous blood volume monitoring (CRIT-LINE) promise to evaluate over- and underhydration precisely and efficiently, while Ultrasound Lung Comet score (ULC's) appears as a suitable new technique. IVCD measurements, correlated well with central venous pressure and reflect changes in blood volume before and after the HD process. BIA is a method for estimating body composition including overhydration, extracellular, intracellular, and total body water in HD patients. CRIT-LINETM monitor is a non-invasive optical method that measures changes in blood volume according to changes in hematocrit during HD sessions. ULC's has recently been shown to be a useful, non-invasive technique for assessment of extravascular lung water.We sought to evaluate and compare the indexed Inferior Vena Cava diameter (IVCD), as a reliable and well-established technique, with the other methods of fluid status assessment (BIA, CRIT-LINE) and newer available technique (ULC's) for estimation of the hydration status of patients undergoing hemodialysis.The study was performed in 53 patients (age 63.4 ± 14.4 years, dialysis duration 6.9 ± 8.3 years) undergoing chronic hemodialysis thrice weekly were included in the study. The evaluation of hydration status methods was applied thrice weekly before and after HD. For the assessment of the inferior vena cava diameter (IVCD) M-mode method with Vivid 3 ultrasound unit was applied while a 2D display technique with Vivid 3 ultrasound unit was applied for the Ultrasound Lung Comet score (ULCs). Overhydration was estimated by BIA method with BCM-Body Composition Monitor (Fresenius Medical Care (FMC) Deutschland GmbH) and Continuous blood volume monitoring with the CRIT-LINE III System (FMC). Comparison of methods was performed with ROC curve analysis, also with comparison of Areas Under the Curve using the nonparametric Friedman test (a two-way analysis on ranks) followed by Dunn’s post-hoc test for multiple comparisons.ULC's showed the most promising results in predicting overhydration, as determined by IVCDi, compared with BIA and Crit-line and presented a sensitivity of 77% and specificity of 74%. The accuracy of the ULC's was higher than that of BIA (0.81 vs 0.71, p = 0.032) and Crit-line (0.61, p = 0.001). Furthermore, ULC's has shown more promising results in predicting underhydration, as determined by IVCDi, than BIA and Crit-line and presented a sensitivity of 78% and a specificity of 73%. The accuracy of the ULC's was higher than that of BIA (0.83 vs 0.76, p = 0.035) and Crit-line (0.50, p < 0.001). Furthermore, Post hoc multiple comparison tests revealed that the AUC of IVCD was not significantly different from the AUC of ULC's. However, in all other cases the AUCs were found significantly different. In the case of overhydration the sensitivity and specificity of ULC's, BIA, Crit-line were 76.9 and 74.2, 89.7 and 45.0, 82.1 and 39.2, respectively. Thus, no difference could be demonstrated between IVCD and ULC's in evaluating the fluid status of HD patients, while comparing BIA to Crit-line, BIA appeared to be more dependable method.Subsequently, the ULC's appears to be a useful and easily performed newer technique for the accurate evaluation of dry weight and fluid status in ESRD patients undergoing chronic HD. This method may help to identify asymptomatic lung congestion in this patient group.

Degree

thesis:*
Grantor dc:publisher
Democritus University of Thrace (DUTH)
Year dc:date
2021

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Alexiadis, Giannis
  • Αλεξιάδης, Γιάννης

Subjects

dc:subject × 14

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/49188

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Alexiadis, Giannis; Αλεξιάδης, Γιάννης. Αξιολόγηση των μεθόδων εκτίμησης της Υδρικής Κατάστασης ασθενών με Χρόνια Νεφρική Νόσο τελικού σταδίου που υποβάλλονται σε αιμοκάθαρση. Democritus University of Thrace (DUTH), 2021. http://hdl.handle.net/10442/hedi/49188