Back to search

Aristotle University Of Thessaloniki (AUTH)

Μελέτη καινοτόμου συστήματος κάλυψης θερμοκηπίου για τη δημιουργία βέλτιστων συνθηκών εσωτερικής θερμοκρασίας

Abstract

dc:description

The Greenhouse sector use is a rapidly growing worldwide. The reduction of agricultural land combined with the ever-increasing need for food makes the efficient operation of greenhouses a key factor for the future. Energy consumption in greenhouses is an important issue, which affects their sustainability sufficiently. The reduction of energy needs is inextricably linked to the reduction of production costs, as well as, to the impact of greenhouse cultivation on the environment.In the present work, an innovative real scale greenhouse construction is experimentally studied, in order to examine whether energy savings and crop frost protection are achieved. The system under study combines the advantages of a greenhouse with a double inflated plastic cover and the one with a thermal curtain system, which both leads to sufficient savings in heat needs. The experiment was conducted at the premises of the AUTh Farm in two identical greenhouses. In the first greenhouse structure the innovative cover was applied, while the second one was used as a control point structure and was covered by a simple polyethylene cover. The necessary temperature conditions were measured through a monitoring and data storage system in order to draw conclusions about both the energy and the environmental behavior of the greenhouse. The assumed crop was selected to have a relatively low optimum growth temperature as the system is efficient at low temperatures. Heating operation though can act as a drawback to the system’s operation and efficiency.The experimental results showed that the application of the examined system limits the use of artificial heating systems in relation to a typical greenhouse by 35-50% depending on the prevailing conditions. It also prevents the growth of ice even in difficult weather conditions compared to a typical greenhouse. Specifically in the greenhouse under the innovative cover, no temperature drop below 0οC was observed on any day of the experimental period although the external conditions were quite rough. The control greenhouse recorded sub-zero temperatures in 23% of the total operating period and in 66% of the hours when the ambient temperature was below 0oC. It was also found, that a reduction of CO2 emissions by 49% occurred over the entire period of operation. It should be noted that the use of additional equipment for the operation of the system implies additional consumption of electricity. This reduces the energy saving rate in the overall operation of the greenhouse to 7%, while for periods of very low temperatures to 25%. Similarly for CO2 emissions, based on theoretical comparisons with heating systems used, it appears that the best solution is that of LPG or electric air heaters in case the system is supported by an electricity grid where the electricity generation mixture does not contain fossil fuels.The innovative greenhouse construction, under consideration, can be a very effective solution for all greenhouse growers that are seeking for ways to reduce heating costs and prevent the growth of ice when extremely low temperatures prevail. Energy savings lead to a reduction of CO2 emissions. It should be noticed that the system could be further improved if its needs were met by a RES system or its’ operation was carried out in a controlled manner based on external ambient temperatures. This cover is mainly suitable for crops with low growth temperatures or for seedlings in nurseries. Finally, it is mentioned that the proposed combined covering could be applied in areas with different climaticconditions. The reason is that the problem of sharp and sufficient temperature drops is currently encountered in more and more areas even if they are located in typical mild climate regions due to climate change.Part of the results of this Thesis, were published in the ISI journal Sustainable Energy Technologies and Assessments with an impact factor of 3,417. The full title of the work is "Energy and environmental analysis of an innovative greenhouse structure towards frost prevention and heating needs conservation" / Firfiris, VK, Fragos, VP, Kotsopoulos, TA, Nikita-Martzopoulou, C. Sustainable Energy Technologies and Assessments, 2020, 40, 100750)

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2020

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Firfiris, Vasileios
  • Φιρφιρής, Βασίλειος

Subjects

dc:subject × 14

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/49264

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Firfiris, Vasileios; Φιρφιρής, Βασίλειος. Μελέτη καινοτόμου συστήματος κάλυψης θερμοκηπίου για τη δημιουργία βέλτιστων συνθηκών εσωτερικής θερμοκρασίας. Aristotle University Of Thessaloniki (AUTH), 2020. http://hdl.handle.net/10442/hedi/49264