Η χρήση των βραχέων μεταφυσιακών στυλεών στην πρωτοπαθή οστεοαρθρίτιδα του ισχίου: ανάλυση πεπερασμένων στοιχείων (finite element analysis), πειραματική εμβιομηχανική μελέτη (experimental biomechanichal testing) και προοπτική, τυχαιοποιημένη συγκριτική μελέτη δυο διαφορετικών στυλεών σε ασθενείς με πρωτοπαθή οστεοαρθρίτιδα του ισχίου

Abstract

dc:description

Total hip replacement has recently followed a progressive evolution towards principles of bone and soft-tissue-sparing surgery. Regarding femoral implants, different stem designs have been developed as an alternative to conventional stems, and there is a renewed interest towards short versions of uncemented femoral implants. The proposed study aims to compare the biomechanical properties and clinical outcomes of two different design metaphyseal fitting short stems, the newly introduced short-stem Minima S (Lima corporate Villanova di San Daniele, Italy), for which clinical data are lacking with an older generation stem, the Tri-Lock Bone Preservation Stem (Tri-Lock BPS, DePuy Orthopaedics Inc. Warsaw, IN, USA) with an established performance record in short to midterm follow-up. In the experimental study, cortical strain distribution was assessed via Digital Image Correlation (DIC) first on the non-implanted femur and then on implanted bones in a single-leg stance loading state. The latter configuration consists of synthetic femurs implanted with the Tri-Lock BPS and the Minima S Femoral Stem. The DIC full-field strain patterns in implanted femurs were then compared with those of the non-implanted femur. Finite element (FE) models of the implanted and non-implanted femurs were developed and evaluated for their validity against mechanical tests. The validation was performed via a direct comparison of the FE calculated strain fields with their experimental equivalents obtained using the digital image correlation technique. A prospective randomized comparative clinical study between these two stems was also conducted to determine the clinical and radiological outcomes up to 2 years’ follow-up. The study findings support the use of DIC technique as a preclinical evaluation tool of the biomechanical behavior induced by different implants and also identify its potential for experimental FE model validation. Linear correlation analyses of the FE model-predicted strains against corresponding experimentally-measured strains revealed a strong correlation indicating that the developed FE models can be used for the calculation of stresses and strains at the implanted femurs. Furthermore, this study demonstrates that stress shielding effect cannot be avoided as proximal unloading of the femur was noted after the implantation of both short stem designs. A distally shifting load distribution pattern as a result of implant insertion and also an obvious decrease of strain in the medial proximal aspect of the femur was noted for both stems. Nevertheless, design specific variations between Tri-Lock BPS and Minima S conditioned different strain pattern distributions. Specifically, strain changes induced after the implantation of the Tri-Lock BPS stem at the lateral surface were greater compared to the non-implanted femur response, as opposed to those exhibited by the Minima S stem. For this reason, the clinical implication of the aforementioned differences was investigated through the comparative prospective clinical study. Both different design short femoral stems demonstrated excellent clinical performance and very low incidence of complications up to 2 years follow up without any evidence of differences in patient-reported outcomes. In both groups, stable fixation and radiographic osseointegration were achieved, with no cases of aseptic loosening, progressive radiolucent lines or periprosthetic osteolysis. In the current comparative clinical study and in accordance with the conclusions of the experimental study, stress shielding phenomenon was also noted after the implantation of both short stem designs. However, the specific dissimilarities in strain distributions induced after the implantation of each prosthesis due to their design specific variations did not induce a clinical visible impact on the radiological parameters investigated in the clinical study. Although our results are in line with previous reports, concerns have been raised regarding the incidence of stress shielding phenomenon and mild discrepancies in coronal stem alignment during implantation. Further multicenter studies with larger cohorts and longer follow-up are needed to evaluate the clinical impact of these concerns if any and also the long-term performance and survivorship of short femoral stems.

Degree

thesis:*
Grantor dc:publisher
University of Patras
Year dc:date
2021

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Tatani, Eirini
  • Τατάνη, Ειρήνη

Subjects

dc:subject × 16

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/49272

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Tatani, Eirini; Τατάνη, Ειρήνη. Η χρήση των βραχέων μεταφυσιακών στυλεών στην πρωτοπαθή οστεοαρθρίτιδα του ισχίου: ανάλυση πεπερασμένων στοιχείων (finite element analysis), πειραματική εμβιομηχανική μελέτη (experimental biomechanichal testing) και προοπτική, τυχαιοποιημένη συγκριτική μελέτη δυο διαφορετικών στυλεών σε ασθενείς με πρωτοπαθή οστεοαρθρίτιδα του ισχίου. University of Patras, 2021. http://hdl.handle.net/10442/hedi/49272