Έλεγχος της ακρίβειας της υπολογιστικής τομογραφίας κωνικής δέσμης (CBCT) στην εκτίμηση του πάχους των περιεμφυτευματικών οστικών πετάλων και των πιθανών συνεπειών των σχετικών artifacts
Abstract
dc:descriptionCone beam computed tomography (CBCT) gave solutions in many diagnostic dilemmas in modern dentistry. At the stage of pre-surgical control in implantology it can provide information that can help the surgeon decide the suitable dimensions (height and width) of the implants. Also it can help with information in regard with the anatomical structures of the areas of interest. Post-surgically it can help to evaluate the health of the bone around the implants and it can provide more information compared with two-dimensional imaging techniques for the planning of correctional surgical procedures.The aim of this study is to evaluate the diagnostic accuracy of Cone beam computed tomography in measuring the width of the cortical plate around implants using various combinations of exposure parameters and also to evaluate the consequences of artifacts caused mainly by the metallic surface of the implants. For the needs of the current study 5 bone blocks were harvested from the mandibles of adult pigs. In each block 2 Biomet 3i Nano-tite Certain 4x10 implants were placed and a radiopaque guide was formed with 1 mm gutta-percha points attached to it at 4 and 8 millimeters from the top of each preparation. A series of tomographies were taken with the implants present and removed using several combinations of exposure parameters. The parameters that were altered were the tube current and voltage and the voxel size. For the tomographies a Planmeca Promax mid 3D cone beam tomograph was used. All the measurements were performed by 2 examiners with adequate experience in interpreting cone beam computed tomographies. The examiners were trained prior to the measurements on how to correctly use the imaging software of the chosen tomograph and they were given verbal and written instructions before each session about the various parameters. The measurements form the cbct’s were compared to the gold standard which was established from direct measurements after dissecting the specimens.The results of the statistical analysis demonstrated that there are almost no significant differences between the measurements taken from the cbct’s and the gold standard for any of the combinations of exposure parameters used (Voxel size , kVp, mA).The few differences that were statistically significant had no clinical value (<1mm).The above conclusions are in agreement with the current literature.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2020
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Sapountzis, Alexandros
- Σαπουντζής, Αλέξανδρος
Subjects
dc:subject × 8Rights
dc:rights- Statement dc:rights
-
- BY_4_0
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/49404