Back to search

Aristotle University Of Thessaloniki (AUTH)

Μελέτη της αρτηριακής σκληρίας ασθενών υπό περιτοναϊκή κάθαρση σε σχέση με την περιπατητική αορτική και βραχιόνιο πίεση

Abstract

dc:description

Arteriosclerosis is a long-term process of structural remodelling of the aorta and large central capacitive arteries. Arteriosclerosis progresses in parallel with ageing, but in some specific clinical conditions, and typically in patients with end-stage-kidney-disease (ESKD), the age-related increase in arterial stiffness is accelerated. The pathogenesis of premature vascular ageing is not yet fully understood, but the accumulation of uremic toxins, maladaptive metabolic and hormonal pathways, chronic inflammation and oxidative stress appear to be important mediators of the accelerated arterial stiffening in ESKD. Arteriosclerosis impairs the cushioning or dampening arterial function and by doing so, this process induces an increase in peripheral and central aortic systolic blood pressure (BP) and pulse pressure (PP), augments left ventricular afterload and mediates the subendocardial hypoperfusion during diastole. The increase in arterial wall pulsation is thereafter transmitted to the peripheral vascular beds, promoting the microcirculatory overflow and microvascular end-organ damage. Therefore, arterial stiffness has been proposed to be a novel marker reflecting macro- and microvascular health, since observational studies have shown high pulse wave velocity (PWV) to be associated with increased risk of adverse cardiovascular events and mortality either in the general population or in patients with ESKD. Tonometric measurement of carotid-to-femoral PWV is held to be the reference-standard method in the non-invasive assessment of the severity of arterial stiffness in daily clinical practice. It has to be noted, however, that this method has a number of drawbacks. Tonometric PWV is operator-dependent and is subjected to errors arising from the imprecise determination of arterial length via superficial anatomic landmarks. Tonometric PWV is also influenced by the white-coat effect, since the measurements are performed in the office environment. The newly-introduced Mobil-O-Graph device (IEM, Stolberg, Genrmany) combines cuff oscillometry and pulse wave analysis, enabling the ambulatory recording of brachial and central aortic BP, augmentation index (AIx) and PWV. Accordingly, the main aim of this thesis was to evaluate the 24-hour ambulatory BP and arterial stiffness in a prospective cohort of 81 clinically stable ESKD patients receiving long-term peritoneal dialysis (PD). Adult ESKD patients receiving PD for at least 3 months in 3 dialysis centers of Northern Greece were enrolled in this cross-sectional observational study. Patients were instructed to visit their PD unit after a 12-hour overnight fast in order to undertake the prespecified protocol procedures that included anthropometric measurements, full physical examination and venous blood sampling for the determination of standard haematological and biochemical parameters. Volume status was also assessed by performing whole-body multi-frequency bioimpedance spectroscopy using the Body Composition Monitor (BCM, Fresenius Medical Care, Bad Homburg, Germany). Clinic BP was recorded in triplicate after a 5-minute seated rest with the validated oscillometric device HEM 705 CP (Omron Healthcare). After the completion of these exams, the Mobil-O-Graph monitor (IEM, Stolberg, Genrmany) was fitted to the non-dominant arm and patients underwent ABPM for 24-hours. Subsequently, the patients were asked to perform home BP monitoring (HBPM) over the next week following a standardized protocol and using the self-inflating automatic monitor HEM 705 CP. In the first part of this thesis, we aimed to compare aortic systolic BP (aSBP), heart rate adjusted AIx (AIx75) and pulse wave velocity (PWV) obtained by the Mobil-O-Graph and Sphygmocor devices (ArtCor, Australia) under static conditions as a preliminary evaluation of the accuracy of the Mobil-O-Graph monitor in the PD population. Accordingly, in a subset of 27 consecutive PD patients, oscillometric and tonometric measurements were obtained after a 10-minute rest in the supine position. The Mobil-O-Graph and Sphygmocor devices were applied in a randomized order. Mobil-O-Graph derived aSBP, AIx75 and PWV did not differ from the relevant measurements taken with Sphygmocor (120.5±18.2 vs 124.4±19.0 mmHg, P=0.438 for aSBP, 27.0±12.4 vs 24.5±10.6%, P=0.428 for AIx75 and 9.5±2.1 vs 10.1±3.1 m/sec, P=0.397 for PWV). The slight difference in estimation of aSBP is possibly explained by the difference in brachial SBP that was used for the calibration of the 2 devices (131.0±20.6 vs 134.5±19.7 mmHg, P=0.525). Mobil-O-Graph-derived parameters were strongly and significantly correlated with paired measurements taken with Sphygmocor (r=0.889, P<0.001 for aSBP; r=0.816, P<0.001 for AIx75; r=0.794, P<0.001 for PWV). Bland-Altman analysis showed no evidence of asymmetry and wide range of agreement between the two devices. Oscillometric PWV derived from the Mobil-o-Graph device is calculated via complex mathematical algorithms utilizing age, oscillometric BP and some other hemodynamic parameters obtained from pulse wave analysis. This algorithmic calculation raises the necessity to identify determinants of oscillometric PWV in ESKD, a setting of premature vascular ageing and accelerated arterial stiffening. On this basis, we explored the association of 24-hour oscillometric PWV with several demographic, clinical and hemodynamic parameters in the overall study population of 81 PD patients using linear regression analysis. In univariate analysis, 24-hour PWV exhibited a positive relationship with age (β: 0.936, Ρ<0.001), body mass index (β: 0.288, Ρ<0.01), diabetic status (β: 0.328, Ρ<0.01), history of dyslipidemia (β: 0.422, Ρ<0.001) and coronary heart disease (β: 0.399, Ρ<0.001). 24-hour PWV had a negative relationship with female sex (β: -0.320, Ρ<0.01) and 24-hour heart rate (β: -0.384, Ρ<0.001). In stepwise multivariate analysis, age (β: 0.895), 24-hour mean BP (β: 0.197) and 24-hour heart rate (β: -0.112) were the only 3 factors that remained as independent determinants of 24-hour PWV (adjusted R2= 0.920). The International Society for Peritoneal Dialysis (ISPD) recommends that adequate assessment of hypertension among patients on peritoneal dialysis (PD) should at least include BP measurements taken once-weekly at home and at each visit at clinic. However, the quality of evidence to support this guidance is suboptimal. In an attempt to cover this scientific gap, we explored the diagnostic performance of clinic and home BP recordings using ambulatory daytime BP as reference standard. The area under the curve (AUC) of receiver operating characteristic (ROC) curves in detection of ambulatory daytime systolic BP (SBP) ≥135 mmHg was similar for clinic [AUC: 0.859; 95% confidence interval (CI): 0.776-0.941] and home SBP (AUC: 0.895; 95% CI: 0.815-0.976). In Bland-Altman analysis, clinic SBP overestimated daytime ambulatory SBP by 5.02 mmHg with 95% limits of agreement ranging from -17.92 to 27.96 mmHg. Similarly, home SBP overestimated daytime ambulatory SBP by 4.23 mmHg, again with wide 95% limits of agreement (-16.05 to 24.51 mmHg). Finally, prior studies showed that peritoneal sodium sieving during the high-frequency and short overnight cycles results in less effective diffusive sodium removal in automated PD (APD) as compared with continuous ambulatory PD (CAPD). These data have generated concerns and uncertainty on the comparative effectiveness of these 2 PD modalities in the achievement of adequate volume and BP control. In a prespecified sub-analysis of this PhD thesis, 28 CAPD patients were matched in 1:1 ratio with 28 controls receiving APD for age, gender and diabetic status. Standardized clinic BP, antihypertensive medication use and extracellular-to-total body water ratio did not differ between CAPD patients and APD controls. 24-hour brachial systolic BP (129.0±17.3 vs. 128.1±14.2 mmHg, P=0.83) and 24-hour aortic systolic BP (116.9±16.4 vs. 116.4±11.6 mmHg, P=0.87) were similar in patients treated with CAPD versus APD. Similarly, there was no significant difference between PD modalities in severity of arterial stiffness, as assessed with 24-hour AIx75 (24.8±8.9 vs. 22.5±9.1, P=0.36) and 24-hour PWV (9.1±2.4 vs. 8.8±2.1 m/sec, P=0.61). In conclusion, the results of our PhD thesis are summarized as follows: (i) The oscillometric device Mobil-O-Graph exhibits acceptable agreement with the tonometric method applied with the use of Sphygmocor device in estimation of central aortic BP and arterial stiffness indices under static conditions in the PD population. (ii) Age together with simultaneously assessed oscillometric BP and heart rate are the major determinants of Mobil-O-Graph-derived PWV, explaining >90% of the total variation of this marker. This age dependence of oscillometric PWV limits the validity of this marker to detect the premature vascular ageing, which is a unique characteristic of vascular remodeling in the PD population. (iii) With respect to the diagnostic performance of different BP monitoring techniques, 1-week averaged home SBP is of at least similar accuracy with standardized clinic SBP in diagnosing hypertension confirmed by ambulatory BP monitoring among PD patients. (iv) With respect to the comparative effectiveness of CAPD versus APD, the present study shows that there is no significant difference in peripheral and central hemodynamic parameters as well as in the severity of arterial stiffness between these 2 PD modalities. The results of this thesis provide the rationale for the design of future prospective observational studies that will evaluate the prognostic association of 24-hour ambulatory BP and arterial stiffness with the risk of adverse cardiovascular events and all-cause mortality among ESKD patients receiving long-term PD.

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2021

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Vaios, Vasileios
  • Βάιος, Βασίλειος

Subjects

dc:subject × 16

Rights

dc:rights
Statement dc:rights
  • BY_NC_ND_4_0
Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/49549

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Vaios, Vasileios; Βάιος, Βασίλειος. Μελέτη της αρτηριακής σκληρίας ασθενών υπό περιτοναϊκή κάθαρση σε σχέση με την περιπατητική αορτική και βραχιόνιο πίεση. Aristotle University Of Thessaloniki (AUTH), 2021. http://hdl.handle.net/10442/hedi/49549