Η αξιολόγηση των χαρακτηριστικών των μονίμων αγγειακών καθετήρων που σχετίζονται με την επανακυκλοφορία και τη σημασία της στην επάρκεια της παρεχόμενης χρόνιας περιοδικής αιμοκάθαρσης
Abstract
dc:descriptionAlthough the NKF-DOQI guidelines recommend the initiation and maintenance of long-term hemodialysis either with an arteriovenous fistula or with an arteriovenous graft, central venous catheters (CVC) comprise the most frequent venous access in patients initiating hemodialysis and remain the permanent venous access for a large proportion of them. Apart from the higher incidence of infection-related events, CVC use is also associated with hazards arising from the inability to achieve the recommended by guidelines dialysis adequacy targets owing to catheter dysfunction.This clinical complication is attributable to a variety of causes, including thrombus formation, fibrin sheath, central vein stenosis, or malposition. A therapeutic approach commonly applied in daily clinical practice to overcome the barrier of catheter dysfunction, attain sufficient blood flow rates and provide adequate dialysis without the necessity for lengthening the duration of renal replacement therapy is to reverse the connection mode of dysfunctioning dual-lumen CVCs.Earlier studies have raised substantial uncertainty on the efficacy of this therapeutic maneuver, showing that dialysis with reversed-connected lines is associated with higher rates of access recirculation that compromise the adequacy of the delivered dialysis. The reported access recirculation was <5% with correct connection but increased up to 15% with reversed connection. The maneuver of reversing the lines in dysfunctional catheters could, nonetheless, be of a certain value, if the augmentation of the delivered dialysis achieved through higher blood flow compensates for the increase in the recirculation rate.The up to now data in the literature came mostly from relatively small studies and the results have often been conflicting. The replacement, however, of a tunneled CVC, apart from the financial burden, constitutes a painful procedure for the patient, with a negative impact on his quality of life. Furthermore, the available and suitable venous-puncture sites gradually run out. With this study we tried to clarify when the reversal of the lines of a dysfunctional catheter is repercussion free, or even beneficial, and when its replacement is necessary.The aim of this study was to investigate prospectively and in a large number of patients how recirculation and hemodialysis adequacy are affected by the CVC site, the CVC’s tip design and the reversal of the lines. In a subgroup of patients, we evaluated additionally the impact of augmenting the blood flow with the lines in the reversed mode on the recirculation and the adequacy.The study population was composed of 118 patients with chronic kidney disease (CKD), under chronic hemodialysis treatment in Therapeutiki Dialysis Units, Protipo Dialysis Unit and the renal departments of General Hospital of Komotini and Papageorgiou Hospital of Thessaloniki. They all had as vascular access a well functioning, tunneled, double lumen catheter, placed in either right internal jugular, left internal jugular, right subclavian or left subclavian vein.For two consecutive weeks and at the mid-week session, patients were evaluated for the dialysis adequacy and the recirculation rate. At baseline (first week), participants were evaluated under standardized conditions (correct connection, Qb=300 ml/min). In Phase A (second week), dialysis was performed with reversed connection and Qb=300 ml/min. A subgroup of 45 patients was evaluated for a third, consecutive, week. In this Phase B, dialysis was performed with reversed connection and Qb=400 ml/min. The sequence of evaluations (Phase A and B or vise verse) was randomized. All other dialysis-related parameters were unchanged in all three occasions.As expected, compared with baseline, reversed-connected dialysis in Phase A resulted in lower URR and spKt/V, and in a higher recirculation rate. Compared with baseline, reversed-connected dialysis with a higher Qb in Phase B resulted in an even higher recirculation rate, but, at the same time, in an improvement of the dialysis adequacy.We also studied a small group of 20 patients with dysfunctional catheters. In this group, the catheters were functional only in the reversed mode. The evaluation was performed during two consecutive weeks, at the mid-week session. The first week (phase A) patients were evaluated for the dialysis adequacy and the recirculation rate, with the lines reversed and Qb up to 300 ml/min. The second week (phase B) the evaluation was made with Qb as high as possible, and the lines, again, reversed. The Qb augmentation resulted in significant improvement in dialysis adequacy, as expressed through URR and spKt/V, and, at the same time, in higher recirculation rate, which was not significant enough to adversly effect these values. The present study shows that dialysis with reversed connection of the permanent hemodialysis catheter could offer reliable dialysis adequacy, with acceptable recirculation rates and results that could improve with a slight extension of the dialysis time, without the need of the immediate substitution of a disfunctioning catheter. Relative to reversed-connected dialysis with a standard blood fow rate (Qb=300 ml/min), increasing the blood fow rate to 400 ml/min improves the adequacy of the delivered dialysis despite the higher rate of access recirculation.These results have important clinical implications and provide some scientifc basis to the reversion of the connection mode of dysfunctioning catheters as an initial, non-interventional, therapeutic approach to achieve the recommended by guidelines targets on dialysis adequacy.
Degree
thesis:*- Grantor dc:publisher
- Democritus University of Thrace (DUTH)
- Year dc:date
- 2021
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Kousoula, Varvara
- Κούσουλα, Βαρβάρα
Subjects
dc:subject × 14Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/49589