Aristotle University Of Thessaloniki (AUTH)
Μελέτη επίδρασης φυσικού αερισμού στο μικρο-περιβάλλον κτηνοτροφικής μονάδας με χρήση τεχνολογίας ανοιχτού κώδικα
Abstract
dc:descriptionThe concentration of ammonia and carbon dioxide, the internal temperature and relative humidity were monitored in a poultry farm of laying hens with natural ventilation in Northern Greece. The measurements were made at three sampling points two meters above the ground using open source device technology and sensors during a period of 12 days in the spring (March-April 2016). The measurements of the carbon dioxide concentrations resulted in the calculation of the ventilation rate by the indirect method of the carbon dioxide balance and subsequently of the ammonia emission rate. Ammonia concentrations were sometimes high but most of the measurements did not exceed 25 ppm. Ammonia concentration showed a considerable increase with increase in temperature and relative humidity. The daily mean values of ammonia concentration varied between 13.49±4.15 to 28.50±5.71 ppm for sampling point SP1, 9.32±3.49 to 29.55±13.52 ppm for sampling point SP2, both near the side openings, and 7.99±2.97 to 29.82±4.16 ppm for sampling point SP3 in the middle of the livestock building below air vents. Large diurnal variations in ammonia concentrations, temperature and relative humidity were observed between daytime and night time due to a decrease in temperature and animal activity. The diurnal ammonia concentrations among sampling points showed slight differences between SP1 & SP2 whereas a noticeable decrease is observed at SP3. Results illustrate the reliability of open source device technology, rendering it a useful tool to monitor pollutant gas concentrations and various microclimatic parameters within naturally ventilated livestock constructions. The average hourly total ammonia concentration is 19.1 ppm while the corresponding value for carbon dioxide is 814.4 ppm which is below the alert threshold. The average hourly internal temperature and relative humidity are 15.6 οC and 47.1% respectively, which are within the limits of thermal comfort providing an ideal microclimate for laying birds. The average indoor air velocity is 2 m/s with its maximum value within the recommended air inlet velocities ranging from 3,048 to 5,080 m/s. The average value of the ventilation rate by the method of the CO2 balance and gave an average value of 5.48 ± 2.91 m3/h /bird with a range of values between 1.54 and 18.60 m3/h/bird. Increasing the rate of ventilation results in a decrease in internal or relative humidity as well as in concentrations of ammonia and carbon dioxide. The average value of the ammonia emission rate for the housing system of laying hens on the floor is 489.9 ± 244.9 g/ d/AU with a minimum value of 132.9 g/ d/AU and a maximum of 1142.65 g/ d/AU. The concentration of ammonia inside the poultry house is moderately correlated with the internal air velocity (r = 0.494) while the ventilation rate is related to the ammonia emission rate showing a positive moderate correlation of mean statistical significance (r = 0.615). Internal temperature positively affects the emission rate of ammonia (r = 0.430) as well as the concentration of internal ammonia (r = 0.561) and carbon dioxide (r = 0.359).
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2021
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Denizopoulou, Anastasia
- Δενιζοπούλου, Αναστασία
Subjects
dc:subject × 12- Φυσικός αερισμός
- Κτηνοτροφική Μονάδα
- Μικροκλιματικές παράμετροι
- Τεχνολογία Ανοιχτού Κώδικα
- Natural ventilation
- Livestock Building
- Micro-climatic parameters
- Οpen Source Technology
- Άλλες Γεωπονικές Επιστήμες
- Γεωπονικές Επιστήμες και Κτηνιατρική
- Other Agricultural Sciences
- Agricultural and Veterinary Sciences
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/49617