Aristotle University Of Thessaloniki (AUTH)
Δυναμική ηλεκτροθερμική ανάλυση συστημάτων μεταφοράς ηλεκτρικής ενέργειας
Abstract
dc:descriptionScope of this PhD thesis is the dynamic electrothermal analysis of electric power transmission systems and more specifically the AAC and ACSR overhead lines, as well as underground cables. Also, a very basic part of this PhD thesis is the calculation of temperature fluctuations due to its continuous load variations and the delay time in which they are noticed. Initially, the dynamic thermal analysis is performed with the ultimate goal of calculating some very important quantities which provide us with very important pieces of information that could not be perceived in the time domain, such as the thermal time constant and especially the thermal impedance of the electric power transmission systems. The dynamic thermal analysis methodology is based on the Network Identification by Deconvolution (NID) methodology and the temperature at each point of the conductor resulting from this analysis, leads to an equivalent model in the frequency domain. In order to calculate the thermal impedance of the overhead power transmission lines, both the problem of the electromagnetic field and the thermal problem for the cases of the overhead conductors of type AAC and ACSR are solved analytically. Also, a simplified thermal model was created for an additional confirmation of the results. Afterwards, a fully joined electrothermal model was created with the Joule losses, and more specifically the density of the Joule losses, being the conjunction between the electromagnetic and the thermal model. The results of the analysis were the calculation of the thermal impedance and its presentation through the Nyquist and Bode diagrams. The analytic calculation for the overhead lines is followed by verification through simulation. From the comparison of the results and the negligible differences that arose for the overhead lines, we conclude that we can trust the simulation method for the case of the underground cable as well. For the underground cable, unfortunately due to its complexity, it was not possible to make an analytic calculation of its thermal impedance through the problems of the electromagnetic field and the thermal problem. Next, there is the methodology for calculating the temperature fluctuations due to its continuous load variations and the delay time in which they are noticed. In order to evaluate and validate the usefulness and reliability of the method used, several measurement experiments were performed. In addition, the proposed methodology is applied in some indicative cases of power transmission system, where the reliability of the method has been validated. Finally, the proposed methodology was applied in four cases with measurement current data from four different indicative months spanning a whole year and representing all the seasons, so we to be able to understand in a better way the pattern of the requested load and to proceed with the appropriate calculations.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2021
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Theodosoglou, Ioanna
- Θεοδόσογλου, Ιωάννα
Subjects
dc:subject × 14- Ηλεκτρομαγνητική & θερμική ανάλυση
- Δυναμική θερμική συμπεριφορά
- Σύνθετη θερμική αντίδραση - Διαγράμματα Nyquist & Bode
- Πρόβλεψη των θερμοκρασιακών διακυμάνσεων σε εναέριες γραμμές μεταφοράς και σε υπόγεια καλώδια
- Electromagnetic & Thermal analysis
- Dynamic thermal behaviour
- Thermal impedance - Nyquist & Bode plots
- Temperature fluctuations' prediction of overhead power lines and underground cables
- Επιστήμη Ηλεκτρολόγου Μηχανικού, Ηλεκτρονικού Μηχανικού, Μηχανικού Η/Υ
- Επιστήμες Μηχανικού και Τεχνολογία
- Ηλεκτρική και Ηλεκτρονική μηχανική
- Electrical Engineering, Electronic Engineering, Information Engineering
- Engineering and Technology
- Electrical and Electronic Engineering