Θεωρητική και πειραματική μελέτη μη- καταστροφικού ελέγχου σιδηρομαγνητικών υλικών με ηλεκτρομαγνητικές μεθόδους

Abstract

dc:description

The eddy current testing (ECT) is a common electromagnetic method for the inspection of structures comprising non-ferromagnetic materials, such as aluminum copper and nickel alloys. Regarding, however, ferromagnetic materials, a major issue in the application of ECT occurs due to the large and non-linear magnetic permeability values. Such a magnetic permeability behavior has an effect on the eddy current signal: it produces a noisy signal, with an amplitude that is similar to the discontinuities’ one. The use of a DC external magnetic field drives the material into magnetic saturation and has a mitigating effect: For high magnetic fields, the material behaves almost like non-ferromagnetic. A thorough study, both experimental and theoretical, is performed on the effect of such an external field on the inspectability of a ferromagnetic tube with axisymmetric grooves that simulate wall loss defects. It is shown that for high magnetic field values that drive the inspected specimen into magnetic saturation, the well known phase analysis technique can be used for the defects’ depth characterization.In general, simulation can be used instead of experiment for difficult geometries and for cases in which the experimental process is not easy. Nevertheless, the utilization of finite element method (FEM) software for the non-linear simulation remains a challenge (the lack of pertinent scientific literature is more than evident). It has been shown that the successful use of a commercial FEM software for such non-linear simulation makes it possible to compare the experimental results with the simulation ones. The results from this comparison are generally very good.Finally, a hybrid analytical solution for defect detection that combines an analytical thin-skin model with the FEM simulation is presented. In this combination, the FEM simulation magnetic field results can be used in the coil impedance equation of the analytical model. The hybrid solution’s benefit is obtaining results faster than the entire simulation using FEM analysis for the ECT inspection. Moreover, the use of the hybrid solution makes it possible to simulate geometries that are not easy to solve with purely analytical techniques.

Degree

thesis:*
Grantor dc:publisher
University of Western Macedonia
Year dc:date
2021

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Kyrgiazoglou, Athanasios
  • Κυργιαζόγλου, Αθανάσιος

Subjects

dc:subject × 15

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/49772

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Kyrgiazoglou, Athanasios; Κυργιαζόγλου, Αθανάσιος. Θεωρητική και πειραματική μελέτη μη- καταστροφικού ελέγχου σιδηρομαγνητικών υλικών με ηλεκτρομαγνητικές μεθόδους. University of Western Macedonia, 2021. http://hdl.handle.net/10442/hedi/49772