National Technical University of Athens (NTUA)
Εναλλακτικές μέθοδοι αντισεισμικού σχεδιασμού στοιχείων οπλισμένου σκυροδέματος
Abstract
dc:descriptionThe present PhD thesis has the title «Alternative methods of seismic design of reinforced concrete structures» and its subject is:1.The research of alternative methods of seismic design of reinforced concrete elements, 2.The evaluation and the comparison of alternative methods with emphasis of Compression Force Path method (CFP) and3.The study of the behavior of such type of elementsThe PhD thesis concentrates to the “low-rise walls” which attain different behavior from the slender concrete elements.The research consisted of experimental and analytical part, while the experimental part contained 2 experimental phases.The first experimental phase contained 6 specimens with dimensions 1060Χ1350Χ150 with three alternative types of reinforcement. More specifically 2 of the specimens have been designed and detailed according to EN1998-1 for DCL demands, 2 other specimens for DCH demands and the last 2 specimens have been designed and detailed according to CFP method.The specimens were not axially loaded. A horizontal cyclic displacement was applied in all specimens increasingly till their failure.From the first experimental phase it was resulted that:1.The specimens attained similar behavior and type of damage and more specifically the failure was concentrated at the area of the compression zone.2.The behavior of the specimens designed according to CFP method attain similar behavior with these that were designed according to Eurocodes.In order to improve the behavior of the specimens, an additional set of specimens was designed. The experimental phase contained 4 specimens with the same dimensions of these of the previous phase and with the reinforcement similar to the specimens designed to CFP method. In two specimens the longitudinal reinforcement was separated from the surrounding concrete so no bond stresses could be developed around the bars. The other two specimens were enhanced at the region of the compression area with embedded steel elements in order to delay the destruction of this zone as was observed in the first experimental phase.The specimens were not axially loaded. A horizontal cyclic displacement was applied in all specimens increasingly till their failure.As a conclusion the specimens with the enhanced end zones have better behavior comparison to previous specimens while the failure of the compressive zone was delayed, and they attained bigger values of ductility.
Degree
thesis:*- Grantor dc:publisher
- National Technical University of Athens (NTUA)
- Year dc:date
- 2021
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Zygouris, Nikolaos
- Ζυγούρης, Νικόλαος
Subjects
dc:subject × 14- Οπλισμένο σκυρόδεμα
- Τοιχώματα οπλισμένου σκυροδέματος
- Μέθοδος τροχιας θλιπτικής δύναμης
- Αντισεισμικός σχεδιασμός
- Reinforced concrete
- Reinforced concrete walls
- Compressive force path theory method
- Seismic design
- Επιστήμη Πολιτικού Μηχανικού
- Επιστήμες Μηχανικού και Τεχνολογία
- Δομοστατική
- Civil Engineering
- Engineering and Technology
- Structural Engineering
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/50004