Back to search

University of Patras

Μελέτη των φυσικών μηχανισμών και παραμέτρων στο μικροχώρο αστικού δρόμου με έμφαση την εναλλαγή αερομεταφερόμενων ρυπαντών με το εξωτερικό αστικό ατμοσφαιρικό πεδίο

Abstract

dc:description

Air pollution in the urban canopy represents a major environmental problem and studying the dispersion of pollutants in cities is not easy. The interaction between air flow and urban obstacles such as buildings creates a complex flow in the road that affects the pollutant dispersion. In highly traffic road cavities a lot of pollutants are concentrated, which due to the low ventilation are trapped between the buildings and is directly dangerous to the health of people who live, walk, work or drive on them, but also indirectly dangerous to the whole city since it consists of a sequence of road cavities. Several parameters affect the dispersion of pollutants in the street canyons, such as the direction and velocity of the ambient wind, the geometry of the building, the aspect ratio of the street canyon, the difference in air temperature of the building and others. Subject of this thesis is the computational investigation and analysis of the flow and dispersion of airborne pollutants and the comparison with field measurements in an urban street canyon. Also, the air flow and the pollutants in the urban street canyon was studied for different geometry scenarios with different aspect ratios and roughness elements on the building surfaces. Τhe results of a sampling campaign carried out in the center of the city of Patras, in the section of Maizonos Street, in a relatively deep street canyon of the city (with an aspect ratio equal to h / w = 2.33 ) during the period between 15 November 2004 and 28 February 2005 were studied and evaluated numericaly. Samples of aerosol particles were collected at various heights (z / h = 0,10, 0,57, 0,75 and 1,00) on the windward side of a multi-storey building, followed by an overall analysis of the mass and composition of the particles. The results explicitly showed that the mass concentration of aerosol particles and most trace elements was higher at street and roof level compared to the intermediate levels of the street canyon (16 and 21 meter level data). Thus, it was concluded that the vertical profiles of the concentrations of traffic-related pollutants do not follow the function of the expected exponential reduction. After evaluating Fluent based on the extensive experimental database created by the wind tunnel study by R.N. Meroney et al., (1995), it was studied both the real geometry (i.e. geometry in which measurements were made) and other geometries with aspect ratios of 1, 2 and 2.33 and with different number and position of balconies as roughness elements on the building facades. The aim was to investigate the effect of the balconies in the flow field, the flow parameters and the dispersion of pollutants into the street canyon. Then the effect of other elements of the cavity such as the galleries and penthouses that are characteristic of the centers of Greek cities was investigated. The numerical results showed that the local air flow and the transport of pollutants were strongly influenced by the vortices created by the roughness elements of the facade (balconies). The emphasis was on the formation (number, power and size) of the vortices in the cavity. It was concluded that the vertical gradient of the aerosol particle and trace element concentrations can be attributed to this complex flow field. In conclusion, the analysis demonstrated the need for high-resolution grids near the source of primary pollutants in urban areas. It was then investigated how the presence of other elements of the cavity (i.e. beyond the balconies), such as galleries and penthouses, affect the structure of the flow field and the vertical distribution of concentration near the building facades. For an aspect ratio of h / w =1, 2 and 2.33), in addition to the balconies, galleries and penthouses were added sequentially and their effect on the structure of the flow field and the concentration field both near the building facades and in the center line of the cavity was investigated. The numerical results clearly indicated that both the flow field and the particle mass concentration affected by the presence of the galleries and the penthouses to the first to hinder the escape of pollutants from the cavity. Finally, the results of the field measurements were confirmed by the simulation carried out for the same street canyon geometry using the commercial computer package ANSYS-FLUENT.

Degree

thesis:*
Grantor dc:publisher
University of Patras
Year dc:date
2021

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Karkoulias, Vasileios
  • Καρκούλιας, Βασίλειος

Subjects

dc:subject × 26

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/50065

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Karkoulias, Vasileios; Καρκούλιας, Βασίλειος. Μελέτη των φυσικών μηχανισμών και παραμέτρων στο μικροχώρο αστικού δρόμου με έμφαση την εναλλαγή αερομεταφερόμενων ρυπαντών με το εξωτερικό αστικό ατμοσφαιρικό πεδίο. University of Patras, 2021. http://hdl.handle.net/10442/hedi/50065