Institutes outside Greece
High output resistance current drive circuits for medical applications
Abstract
dc:descriptionThe research described in this thesis is concerned with the analysis, design and development of high output impedance current drive circuits for medical applications. These circuits are used in medical systems such as Electrical Impedance Tomography (EIT) imaging. The target specification for EIT was an output impedance in excess of 1MΩ at 1MHz. Several different current output circuits have been studied together with a variety of circuit techniques which increase the level of output impedance to achieve this objective. All the circuits reported here are bipolar junction transistor level implementations and have been examined using theoretical analyses, and circuit simulation using SPICE. The majority of the results of this work have been reported by the author in the technical literature.The thesis begins with a study and some initial measurements in order to determine the applicability and suitability of the SPICE transistor model parameters. This was necessary because the output impedance target means that second order effects cannot be neglected. The results of this work led to novel methods of determining rμ of the transistor, and were subsequently published by the author.The next part of the thesis focuses on a review of traditional current output circuits and a critical analysis of their performance and their suitability for medical applications. One unusual circuit, published by Baxandall and Swallow in 1966 (B&S) originally intended for audio applications, was of particular interest. These authors demonstrated that their circuit exhibited a much higher output impedance, in excess of 200MΩ over traditional current source designs. Based on this topology author of this thesis reports a novel current output drive circuit capable of achieving a low frequency output impedance in excess of 200GΩ at 1Hz.Finally, a transistor level high output impedance current drive circuit design which is ideally suited for ASIC realisation was developed and studied in detail. In this novel architecture a current sensing technique was used in a feedback loop employing an op-amp and modified configurations based on a core B&S circuit. The output impedance far exceeded the EIT specification of 1MΩ at 1MHz. This work has also been published by the author.
Degree
thesis:*- Grantor dc:publisher
- Institutes outside Greece
- Year dc:date
- 2006
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Terzopoulos, Nikolaos
- Τερζόπουλος, Νικόλαος
Subjects
dc:subject × 11- Πηγές ρεύματος για ιατρικές εφαρμογές
- Τομογράφος ηλεκτρικής εμπέδησης
- Ηλεκτρονικά κυκλώματα
- Current sources for medical applications
- Electrical impedance tomography
- Επιστήμη Ηλεκτρολόγου Μηχανικού, Ηλεκτρονικού Μηχανικού, Μηχανικού Η/Υ
- Επιστήμες Μηχανικού και Τεχνολογία
- Ηλεκτρική και Ηλεκτρονική μηχανική
- Electrical Engineering, Electronic Engineering, Information Engineering
- Engineering and Technology
- Electrical and Electronic Engineering
Rights
- Language dc:language
- eng
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/50356