Back to search

National and Kapodistrian University of Athens

Σύγκριση καρδιο-πνευμονικών μεταβλητών μεταξύ υψίσυχνου αερισμού χαμηλών συχνοτήτων με ή χωρίς ενδοτραχειακή εμφύσηση οξυγόνου και υψίσυχνου αερισμού υψηλών συχνοτήτων σε ασθενείς με βαρύ σύνδρομο αναπνευστικής δυσχέρειας (ARDS)

Abstract

dc:description

Introduction. Acute Respiratory Distress Syndrome (ARDS) is an acute inflammatory state of the pulmonary parenchyma that causes hypoxemia, atelectasis, pulmonary congestion, and reduction in pulmonary compliance. Mechanical ventilation is life-saving, but may traumatize the lungs (eg volutrauma, barotrauma, atelectrauma, and biotrauma). The use of low (i.e. 5-8 mL/kg predicted body weight) tidal volumes, and high positive end-expiratory pressure (PEEP), aims at attenuating ventilator-associated lung injury. However, ARDS mortality still remains high. High frequency oscillation (HFO) is an alternative ventilatory strategy that employs tidal volumes of less than 4 mL/kg predicted body weight administered at frequencies of 3 to 15 Hz. Prior studies have reported improvements in oxygenation, whereas more recent two-center data on severe ARDS suggested a survival benefit from the intermittent, combined use of "low"-frequency (i.e. approximately 4 Hz) HFO with a tracheal tube cuff leak, and tracheal gas insufflation (TGI). Two recently published, multicenter, randomized clinical trials compared "high"-frequency (i.e. 5.5-7.8 Hz) HFO without a cuff leak with low-tidal volume and moderate-PEEP or high-PEEP conventional ventilation and reported either neutral results or an HFO-induced harm in early ARDS. Accordingly, current guidelines do not recommend the routine use of HFO in ARDS. However, a recently published, patient-level meta-analysis of 4 multicenter HFO trials suggested an HFO-related survival benefit in severely hypoxemic ARDS.Negative major trial results on HFO could be partly attributable to right ventricular (RV) overload, dysfunction, and failure caused by the combination of high intrathoracic pressures and hypercapnia. In the present physiological study, we tested the hypothesis that a "low"-frequency HFO strategy using a cuff leak (with or without TGI) and high bias flow might result in improved RV function as compared with a "high"-frequency HFO strategy without cuff leak or TGI. Aim-Method. In this study we compared the HFO protocol used in the OSCILLATE trial, which elicited harmful effects and was prematurely stopped, with a “protective for the right ventricle” HFO strategy, in patients with moderate-to-severe ARDS [PaO2-to-inspiratory O2 fraction ratio (PaO2/FiO2)< 150]. This strategy incorporates cuff leak and tracheal gas insufflations, in order to counteract the deleterious effects on right ventricle physiology and haemodynamic status. Patients underwent hourly courses of HFO 4 Hz, HFO 4 Hz TGI, both with cuff leak, and HFO 7 Hz without cuff leak, in a randomized order. For every ventilation strategy, a transoesophageal cardiac ultrasound was performed to determine the left and right end-diastolic area (RVEDA, LVEDA) and calculate the RVEDA/LVEDA ratio, the right ventricle end-systolic area (RVESA) and the tricuspid annular plane systolic excursion-TAPSE. The RV fractional area change (FAC) was then calculated as (RVEDA – RVESA) / RVEDA. The transgastric imaging data were used to determine the end-diastolic eccentricity index and the end-systolic eccentricity index. Eccentricity indexes were calculated as the quotients of LV diameter D1 and LV diameter D2; D2 was defined as the LV diameter that was perpendicular and bisecting the interventricular septum, and D1 was defined as the diameter that was perpendicular to D2. At the same time, data regarding the respiratory system mechanics and haemodynamic status were recorded. End points included: Primary: RVEDA/LVEDA ratio [>0.6 to 0.9 indicates RV dysfunction; >0.9 indicates RV failure]; Eccentricity index. Secondary: PaO2/FiO2, PaCO2, mean intra-arterial pressure, cardiac index, and respiratory compliance before and after HFO. Results. In total we studied 17 non-consequtive patients. RVEDA/LVEDA was significantly lower during 4-Hz HFO (0.56±0.14) and 4-Hz HFO-TGI (0.52±0.1) compared to7-Hz HFO (0.64±0.15). End-diastolic and end-systolic eccentricity indexes increased during 7-Hz HFO (1.33±0.19) relative to 4-Hz HFO (1.2±0.1), 4-Hz HFO-TGI (1.17±0.11), and post-HFO CV (1,17±0,19). Oxygenation and shunt fraction were significantly improved during the HFO strategies compared to conventional ventilation. PaCO2 was highest and arterial pH lowest during 7-Hz HFO.Quasistatic respiratory compliance (12.0±4.0 vs 13.5±3.6 cmH2O), end-inspiratory plateau pressure (29.9±4.4 vs 27.9±4.4 cmH2O) and driving pressure (12.0±4.0 vs 13.5±3.6 cmH2O) of post-HFO conventional ventilation were significantly improved relative to pre-HFO conventional ventilation.Mean arterial pressure was significantly higher during 4-Hz HFO and HFO-TGI compared to pre-HFO conventional ventilation. Cardiac index was relatively stable throughout the study period, but was higher (by approximately 10% on average) during 4-Hz HFO-TGI relative to 7-Hz HFO.PaCO2 and RV fractional area change were independent predictors of the RVEDA/LVEDA ratio (R2 = 0.25) and the end-systolic eccentricity index (R2 = 0.38). PaCO2 was the sole independent predictor of the end-diastolic eccentricity index (R2 = 0.28).Conclusion. In moderate-to-severe ARDS exhibiting favorable oxygenation response to HFO with mPaw “optimized” according to pre-specified SpO2 and TEE-derived RVEDA/LVEDA criteria, short-term 4-Hz HFO or 4-Hz HFO-TGI with cuff leak resulted in better RV function compared to 7-Hz HFO without cuff leak, and similar or even improved RV function relative to lung protective CV. These results could be partly explained by an effective PaCO2 control during 4-Hz HFO and 4-Hz HFO-TGI.

Degree

thesis:*
Grantor dc:publisher
National and Kapodistrian University of Athens
Year dc:date
2021

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Anninos, Ektor
  • Άννινος, Έκτωρ

Subjects

dc:subject × 14

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/50624

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Anninos, Ektor; Άννινος, Έκτωρ. Σύγκριση καρδιο-πνευμονικών μεταβλητών μεταξύ υψίσυχνου αερισμού χαμηλών συχνοτήτων με ή χωρίς ενδοτραχειακή εμφύσηση οξυγόνου και υψίσυχνου αερισμού υψηλών συχνοτήτων σε ασθενείς με βαρύ σύνδρομο αναπνευστικής δυσχέρειας (ARDS). National and Kapodistrian University of Athens, 2021. http://hdl.handle.net/10442/hedi/50624