Abstract
dc:descriptionSepsis, a syndrome characterized by severe organ dysfunction, is caused by a dysregulated host immune response to infection and is one of the most common causes of morbidity and mortality worldwide. Early sepsis diagnosis is crucial for the timely initiation of an effective treatment in order to increase survival chances. This need for rapid and reliable diagnosis has led to introduction of various biomarkers whose the determination of concentration in the blood could contibute to sepsis diagnosis and/or prognosis. Towards the same direction, biosensors have been proposed as analytical tools for the determination of sepsis biomarkers since they can be incorporated to portable bioanalytical systems for determinations at the point of care. In this context, the aim of this doctoral thesis was to develop an optical immunosensor based on White Light Reflectance Spectroscopy (WLRS) for the simultaneous label-free determination of sepsis biomarkers. The targeted biomarkers were C-reactive protein (CRP), procalcitonin (PCT) and interleukin-6 (IL-6). The detection of these biomarkers is based on the real-time monitoring of the changes in interference spectrum created upon reflection of white light on a silicon/silicon dioxide chip where the specific antibody against each biomarker has been immobilized. Prior to immunosensor development, enzyme-linked immunosorbent assays were developed for each biomarker separately in order to evaluate the available immunoreagents and select the basic conditions of each assay. The immunoassays were then transferred to the optical biosensor, where the chemical and biological modification of chips were first studied and then the assay conditions for each biomarker were optimized. The method developed for CRP determination with the WLRS biosensor was rapid (12 min) and had a limit of detection (1 ng/mL) that allowed dilution of serum samples 20 to 1000 times to cover both the physiological (<5 μg/mL) and pathological CRP concentration range (>100 μg/mL). Regarding the determination of PCT and IL-6, the optimized assay protocols were similar allowing their simultaneous determination using silicon chips with two areas of different thickness of silicon dioxide. The limits of detection achieved were 2 and 0.01 ng/mL for PCT and IL-6, respectively, while the total analysis time was 35 min. Finally, a small-size automated bioanalytical device based on the WLRS biosensor was developed and evaluated for the determination of the three biomarkers at the point-of-care. To evaluate the immunoassays for CRP, PCT and IL-6 performed with the developed device serum samples were analysed and the concentrations detertmined were compared to those found on the same samples when analyzed by a certified clinical laboratory method. The results demonstrated a satisfactorily correlation of concentrations determined by the two methods. Thus, the immunochemical methods and the bioanalytical device developed are expected to facilitate the point-of-care determination of biomarkers related to sepsis diagnosis/prognosis and other pathological situations.
Degree
thesis:*- Grantor dc:publisher
- University of Patras
- Year dc:date
- 2021
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Tsounidi, Dimitra
- Τσουνίδη, Δήμητρα
Subjects
dc:subject × 22- Διάγνωση σήψης
- C αντιδρώσα πρωτεΐνη (CRP)
- Προκαλσιτονίνη (PCT)
- Ιντερλευκίνη-6 (IL-6)
- Οπτικός ανοσοαισθητήρας
- Φασματοσκοπία ανάκλασης λευκού φωτός
- Ταυτόχρονος προσδιορισμός βιοδεικτών
- Βιοαναλυτική συσκευή
- Sepsis diagnosis
- C reactive protein (CRP)
- Procalcitonin (PCT)
- Interleukin 6 (IL-6)
- Optical immunosensor
- White light reflectance spectroscopy
- Simultaneous biomarkers determination
- Bioanalytical device
- Χημεία
- Φυσικές Επιστήμες
- Αναλυτική χημεία
- Chemical Sciences
- Natural Sciences
- Analytical Chemistry
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/50834