Aristotle University Of Thessaloniki (AUTH)
Μελέτη δεικτών υπερυδάτωσης σε ασθενείς με Χρόνια Νεφρική Νόσο Τελικού Σταδίου υπό αιμοκάθαρση
Abstract
dc:descriptionIntroduction: Overhydration is one of the most common clinical issues that patients with end-stage renal disease (ESRD) on haemodialysis have to deal with. It is associated with arterial hypertension (AH) as well as with left ventricular hypertrophy and seems to increase mortality. The prognostic value of simple clinical indices (crackle sounds, edema and BP) to detect overhydration in haemodialysis patients has been evaluated rather partially until now. Existent evidence supports a weak correlation of crackles and pedal edema with overhydration. On the other hand, it seems that BP shows a more proportional relation with volume overload in this group of patients. Aim: Primary aim of this study was to evaluate the ability of physical examination in the detection of overhydration. Secondary aims were a) to estimate the prevalence and the rates of treatment and control of hypertension using peridialytic as well as home BP measurements (Home Blood Pressure Monitoring, HBPM) b) to evaluate the accuracy of peridialytic and intradialytic BP measurements in the detection of hypertension c) to search for possible determinants of inadequate home BP control in the study population. Design: It was an observational cross-sectional study. One hundred and twenty (120) patients with ESRD on haemodialysis were included in the study. Patients’ evaluation was performed once before and after dialysis session and was including a) assessment of volume status with the method of Bioelectrical Impedance (BIA) b) physical examination for the presence of pedal edema and crackle sounds. Subsequently, participants were asked to perform HBPM for one week. Predialytic, intradialytic (at the 1st, 2nd and 3rd hour) and postdialytic measurements of BP over the following six consecutive dialysis sessions, were also recorded. Results: Patients within the higher tertile of volume overload were treated with haemodialysis for a longer time, had higher home systolic BP and lower serum albumin compared with those in the low tertile. Also, they had higher probability to be treated with classical haemodialysis than with haemodiafiltration. The rate of pedal edema or crackle sounds presence did not differ significantly across hydration tertiles. Additionally, ROC curve analysis showed low discriminatory ability of the above two clinical signs in the detection of volume overload, either before or after dialysis session. Finally, in multivariate analysis, time on dialysis and home systolic BP showed a significant positive correlation with volume overload, while the use of haemodiafiltration showed a negative correlation. Regarding the epidemiology of AH in haemodialysis, we observed that the rates of BP control were 32,6%, 50,5% and 45,3%, when home, predialysis and postdialysis BP recordings were used, respectively. Besides, intradialytic BP measurements could more precisely detect AH (as it was defined by weekly home BP recordings) than peridialytic ones. Finally, the three independent determinants of uncontrolled interdialytic hypertension were volume overload (either before or after dialysis), greater antihypertensive drug use and lower dialysis adequacy. Conclusions: Home systolic BP but not physical examination seemed to precisely predict overhydration in haemodialysis patients. Peridialytic BP measurements overestimated hypertension control rate when compared with home BP measurements. Additionally, they showed lower accuracy than intradialytic BP measurements in the detection of AH. Volume overload and extended use of antihypertensive drugs were the main determinants of inadequate home BP control.
Degree
thesis:*- Grantor dc:publisher
- Aristotle University Of Thessaloniki (AUTH)
- Year dc:date
- 2021
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Tsikliras, Nikolaos
- Τσίκληρας, Νικόλαος
Subjects
dc:subject × 14Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/50848