National and Kapodistrian University of Athens
Εμβιομηχανική ανάλυση ασθενών που έχουν υποβληθεί σε δύο διαφορετικούς τύπους ολικής αρθροπλαστικής ισχύου: ceramic on ceramic vs ceramic on XLPE
Abstract
dc:descriptionTotal hip arthroplasty (THA) is considered an extremely successful orthopedic surgery that provides excellent clinical results, high patient satisfaction, followed by a very satisfactory life expectancy. According to recent data from the British National Joint Registry, the cumulative survival of THA at 13 years is 93.2%, with 80% of implants surviving for up to 20 years.Polyethylene wear was considered the weak link of total hip arthroplasty. Over the last decade, considerable effort has been made to optimize wear characteristics and introduce alternative bearing surfaces. The introduction of high cross-linked polyethylene (XLPE) with excellent wear characteristics has brought about significant changes in this field worldwide. Ceramic femoral heads represent the current trend in many national registries.In vitro experiments simulating kinematics and gait kinetics showed advantages of Ceramic to Ceramic (CoC) prostheses compared to Polyethylene Ceramic (CoP) prostheses in terms of the degree of wear and the possibility of osteolysis. Disadvantages, however, include squeaking sounds and increased fragility. In addition, in CoC (hard-on-hard) articulated surfaces, it is impossible to dampen a soft material, and therefore the forces of transition between prosthesis and bone could be increased.Various factors are associated with wear, such as implant design variables (geometric properties and material characteristics), surgical technique variables (surgical approach and prosthesis placement), and patient-related factors. In the latter, the contact force of the hip, determined by human movement, significantly affects the wear of polyethylene. The hip torques at the sagittal level explain between 42% and 60% of the degree of wear, directly linking the kinematic gait pattern to the wear of the implants. Although clinical trials directly correlate the kinematic gait pattern with polyethylene wear in total knee arthroplasties, to the best of our knowledge, no in vivo research has examined OAI kinematics and its relationship to implant wear.The ISO Organization defines wear on OAIs as the loss of material from the prosthetic joint components due to the combination of movement and loading and is affected by various factors. One of the most important is the kinematics and the kinetics of the joints when walking. This is why kinematics and gait kinetics are used in "in vitro" test protocols, widely accepted methods for predicting OAI wear. Any new material or design is questioned if the corresponding clinical performance does not confirm the prediction.It is a fact that all implants are tested with the same kinematic protocol in vitro, and as mentioned above CoC prostheses show advantages in the degree of wear compared to Ceramics in High Cross Polyethylene (CoXLPE) prostheses in these tests. An important question that arises is, "Do the implants in question offer the same biomechanical behavior in clinical practice?"The purpose of this study is to examine the effect of kinematic and kinetic gait on OAI wear during gait, an essential human functional activity, comparing in vivo gait data with in vitro results. This data will be valuable when combined with all of the above factors that affect OAI wear to address in a more detailed and comprehensive manner the wear of CoC and CoXLPE, the most widely used prosthetic types. The null hypothesis of the present study is that both types of implants will exhibit the same joint kinematic and kinetic behavior during gait, thus confirming the aforementioned in vitro results, also in vivo.Independent t-tests were used for the statistical analysis of kinetic and kinematic data extracted from the three-dimensional gait analysis. No statistically significant differences were observed in the mean abduction, bending, and extension torque between the CoC and CoXLPE groups (P. abduction = 0.125, P. flexion = 0.218, P. extension = 0.082). Kinematic measurements also show no statistically significant differences. OAI kinematics and gait kinetics are important industrial parameters that are directly related to implant wear. In vitro studies report less CoC damage than CoXLPE when tested with the same kinematic gait cycle protocol. Our findings confirm that both implants behave identically in terms of kinematics in the clinical setting, thus enhancing the in vitro results of the CoC advantage. In conjunction with all the other essential factors influencing wear on OAIs, it could offer a more comprehensive CoC, and CoXLPE wear assessment.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2022
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Triantafyllou, Athanasios
- Τριανταφύλλου, Αθανάσιος
Subjects
dc:subject × 16- Εμβιομηχανική ολικής αρθροπλαστικής ισχίου
- Κινηματική ολικής αρθροπλαστικής ισχίου
- Κινητική ολικής αρθροπλαστικής ισχίου
- Φόρτιση κεραμικού σε κεραμικό
- Φθορά κεραμικού σε XLPE
- Total hip arthroplasty biomechanics
- Total hip arthroplasty kinematics
- Total hip arthroplasty kinetics
- Ceramic on ceramic THA loading
- Ceramic on XLPE wear
- Κλινική Ιατρική
- Ιατρική και Επιστήμες Υγείας
- Ορθοπεδική και Αθλιατρική
- Clinical Medicine
- Medical and Health Sciences
- Orthopedics and Sports Medicine
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/50861