National and Kapodistrian University of Athens
Συγκριτική μελέτη αερισμού με διαφυγή και χωρίς διαφυγή στην έκβαση της παρατεταμένης νεογνικής ασφυξίας
Abstract
dc:descriptionBackground: Severe and prolonged asphyxia can result in either intrauterine fetal death and stillbirth or multiorgan failure in surviving neonates. Establishing effective ventilation is the primary aim of resuscitation in newborns with asphyxia. The objective of this study was to compare the outcome of resuscitation by applying an endotracheal tube (ETT) with less, an ETT with moderate, and an ETT with high leakage during mechanical ventilation in swine neonates after a prolonged perinatal asphyxia. Methods: A prospective, randomized controlled laboratory study was performed. Thirty Landrace / Large-White pigs, aged 1-4 days and weighted 1.754±218gr, were randomly allocated into three groups depending on the ETT size: Group C (less leak: ETT no 4.0, n=10). Group A (high leak: ETT no 3.0, n=10) and Group B (moderate leak: ETT no 3.5, n=10). Mechanical asphyxia was performed until their heart rate was less than 60 bpm or their mean arterial pressure was below 15 mmHg. All animals with Return of Spontaneous Circulation (ROSC) were monitored for 4 hours for their hemodynamic parameters, arterial oxygen saturation and lactate acid levels.Results: We demonstrate that 70% of the surviving animals were ventilated with an ETT with leak (no 3.5 and 3). It was noted a statistically significant difference in PO2 (p=0.032) between Group B (126.4±53.4 mmHg) compared to Group A (72.28±29.18mmHg) and Group C (94.28±20.46mmHg) and also in the right atrial pressure (p<0.001) between Group C (4,5mmHg) vs Groups A (2mmHg) and B (2mmHg) during in ROSC time. Lactate levels were statistically significantly lower (p=0.035) in Group C (mean=0.92 ± 0.07mmol/L) compared to Group A (mean=1.13 ± 0.1mmol/L) and Group B (mean= 1.08 ± 0.07mmol /L; p = 0.034) at 4h post-ROSC. Conclusion: We provide preliminary evidence that ventilation with ETT with moderate leakage improves survival after 2h of ROSC, along with oxygenation and hemodynamic parameters in a porcine model of neonatal asphyxia and resuscitation, compared to less leakage ETT.
Degree
thesis:*- Grantor dc:publisher
- National and Kapodistrian University of Athens
- Year dc:date
- 2022
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Douvanas, Alexandros
- Δουβανάς, Αλέξανδρος
Subjects
dc:subject × 14- Νεογνική ασφυξία
- Νεογνική αναζωογόνηση
- Χοίρειο μοντέλο
- Ανάκτηση αυτόματης κυκλοφορίας
- Νeonatal asphyxia
- Neonatal resuscitation
- Swine model
- Return of spontaneous circulation
- Κλινική Ιατρική
- Ιατρική και Επιστήμες Υγείας
- Παιδιατρική, Νεογνολογία και Υγεία του παιδιού
- Clinical Medicine
- Medical and Health Sciences
- Pediatrics, Perinatology and Child Health
Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/50870