University of Thessaly (UTH)
Σύγκριση μεθόδων αιμόστασης κερκιδικής αρτηρίας μετά από ενδοστεφανιαίες επεμβάσεις με κερκιδική προσπέλαση
Abstract
dc:descriptionBackground. Radial artery obstruction is the most common complication of coronary angiography performed via trans-radial access. Patent hemostasis can significantly reduce the risk of radial artery occlusion. The most appropriate method for successful patent hemostasis however remains unknown. Aims. To determinewhich method (pulse oximeter versus the traditional radial artery palpation) is better to achieve patent hemostasis.Methods.This is a prospective, single center study, which included 299 consecutive patients who underwent coronary angiography or percutaneous coronary intervention between November 2017 and July 2019. Patients less than 18 years old, with a history of radial artery disease or no palpable artery pulse were excluded from the study. Patients were randomly assigned into two groups. In the first group, radial artery flow was assessed by palpation of the artery during hemostasis (traditional method). In the second group, radial artery patency was estimated with the use of a pulse oximeter. Two different compression devices were used for hemostasis (air chamber and pressure valve). The primary endpoint of the study was the achievement of successful patent hemostasis.Results: The two groups (pulse oximeter vs artery palpation) had no significant differences in age, sex, body mass index, risk factors and comorbidities except for supraventricular arrhythmias. The percentage of patients with successful patent hemostasis was significantly higher in the pulse oximeter group (82.2% vs 68.1%, p = 0.005). A lower percentage of patients with spasm was recorded in the pulse oximeter group (9,9% vs 19%, p = 0.024). The incidence of local complications, edema, bleeding, hematoma, vagotonia, or pain did not differ between the two groups. In the multivariate analysis, the use of pulse oximeter (Odds Ratio (OR): 2.35, 95% Confidence Interval (CI): 1.34 - 4.13, p = 0.003) and advanced age (OR: 1.04, 95% CI: 1.01 - 1.07, p = 0.006), were independently associated with an increased probability of successful patent hemostasis.The type of hemostatic device did not affect patent hemostasis (p = 0.450).ConclusionsPatent hemostasis with the use of pulse oximeteris a safe and promising method, worthy of further investigation. Larger randomized studies are required to consider its clinical implications.Key words: Radial access; Patent hemostasis; Palpation; Oximeter; Coronary angiography; Radial artery occlusion.
Degree
thesis:*- Grantor dc:publisher
- University of Thessaly (UTH)
- Year dc:date
- 2022
Author and committee
dc:creator, dc:contributor.*- Authors dc:creator
-
- Kyriakopoulos, Vasileios
- Κυριακόπουλος, Βασίλειος
Subjects
dc:subject × 10Rights
- Language dc:language
- gre
Identifiers
dc:identifier.*- Identifier
- 10.12681/eadd/50949