Back to search

University of Patras

Προοπτική, συγκριτική, τυχαιοποιημένη μελέτη μεταξύ περιφερικής (Cortical Button) και κεντρικής (AperFix AM) ανατομικής μηριαίας στερέωσης του μοσχεύματος ισχιοκνημιαίων (hamstrings) στην αρθροσκοπικά υποβοηθούμενη συνδεσμοπλαστική του προσθίου χιαστού συνδέσμου

Abstract

dc:description

Introduction: Arthroscopically-assisted anterior cruciate ligament (ACL) reconstruction is the more adapted surgical technique for restoring the anteroposterior and rotational instability of the knee, following a traumatic ACL injury. Except graft’s type, that usually lies in the surgeon’s preference, recent research has focused on graft stabilization systems within the bone tunnels, in order to achieve adequate primary fixation that allows optimal graft integration as well as early mobilization of the patient.Purpose: The purpose of the present study was to evaluate and compare the clinical results, knee laxity, femoral tunnel enlargement and muscle deficit imbalances, between two different femoral stabilization devices for ACL reconstruction with hamstrings autograft: standard Cortical Button (Stryker, Johnson) and the new Aperfix® AM system (Cayenne Medical - Zimmer Biomet Company) which theoretically provides increased graft compression inside the tunnel and is also equivalent to the "double bundle" ACL technique, due to the rotation capability of the graft that resembles the normal anatomy of the ligament.Method: After we performed prospective power analysis and obtained institutional review board, 70 patients with ACL rupture were block randomized to 2 groups (35 in each one): the fixed loop suspensory Cortical Button (Group A) and the expandable aperture fixation system (Group B). All patients received autologous hamstring autograft through the anteromedial portal and fixed with a sheath-screw system and a staple in the tibia. The primary outcome measures were anteroposterior knee stability at 2 years follow-up measured using the KT-1000 Knee Ligament Arthrometer (MEDmetric Corp, San Diego, CA, USA) and the degree of femoral and tibial tunnels’ widening measured by the use of computed tomography imaging performed immediately postoperative and 12 months post-surgery. Secondary outcome measures included pain score on a visual analog scale, the subjective International Knee Documentation Committee 2000 assessment form, the Lysholm score, the Tegner activity scale and the muscle deficit ratio using Cybex Norm 770, at 3, 6, 12 and 24 months.Results: Twenty-four patients were excluded from further analysis, leaving a total of 48 patients (24 in each group) for the final evaluation. The anteroposterior knee stability (KT-1000) showed no difference between groups at 24 months follow-up (P=0.33). The percentile widening (%) of femoral and tibial tunnel at 1-year follow-up showed no difference also, except for greater values at the tibial coronal point T2 (P=0.007) and tibial sagittal point T1 (P=0.035) in the group of cortical buttons. Secondary clinical outcomes showed no statistical differences between groups at 3, 6, 12 and 24 months postoperatively. Numerical pain scale (visual analog scale) was similar in both groups except for postoperative day 7, where the AperFix group showed better results (P=0.012). Isokinetic analysis showed no statistically significant differences concerning the muscle deficits between the above groups at 2 years, both for extensors (P=0.739) and flexors (P=0.699). However, in our research it appeared that there were some patients from the population who failed to correct the muscle deficits even 2 years after the surgery, in extensors (P=0.366) or flexors (P=0.919). There were no major intraoperative and late postoperative complications in any of the groups.Conclusions: The Aperfix® AM (through the anteromedial portal) technique for hamstring’s ACL reconstruction found not superior in comparison with the Cortical Button group, concerning knee anteroposterior stability, tunnel enlargement, muscle deficits or other clinical outcomes at 24 months follow-up.

Degree

thesis:*
Grantor dc:publisher
University of Patras
Year dc:date
2022

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Mylonas, Dimitrios
  • Μυλωνάς, Δημήτριος

Subjects

dc:subject × 20

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/51146

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Mylonas, Dimitrios; Μυλωνάς, Δημήτριος. Προοπτική, συγκριτική, τυχαιοποιημένη μελέτη μεταξύ περιφερικής (Cortical Button) και κεντρικής (AperFix AM) ανατομικής μηριαίας στερέωσης του μοσχεύματος ισχιοκνημιαίων (hamstrings) στην αρθροσκοπικά υποβοηθούμενη συνδεσμοπλαστική του προσθίου χιαστού συνδέσμου. University of Patras, 2022. http://hdl.handle.net/10442/hedi/51146