Back to search

Aristotle University Of Thessaloniki (AUTH)

Απομάκρυνση μικρορύπων από επιρυπασμένα νερά με την εφαρμογή του καταλυτικού οζονισμού

Abstract

dc:description

Water is a valuable source, important for the living organisms and the human activities. However, various emerging contaminants end up to the aquatic environment having a negative impact on the water quality. The wastewater treatment plants are not able to remove entirely the organic compounds that occur in the wastewaters at low concentrations (micropollutants) making the treatment inefficient in dealing with this specific pollution problem. Ozonation process is widely used in the production of drinking water and in tertiary treatment of municipal wastewaters. However, the majority of the organic micropollutants posses relatively low reaction rate constants with ozone making the process inefficient, time consuming and economically unprofitable. Recent studies have shown that the application of catalytic ozonation can increase the efficiency of the ozonation systems. The aim of this doctoral thesis is the study of the homogeneous and heterogeneous catalytic ozonation processes in order to find the appropriate materials for the efficient removal of the micropollutants from waters and the investigation of the basic mechanisms in which the removal of these compounds is depended on. To achieve this goal 5 transition metal ions (Co(II), Fe(II), Mn(II), Ni(II) and Zn(II)) were used as homogeneous catalysts and 18 different solid materials as heterogeneous. Also, the removal of 8 micropollutants (atrazine, benzotriazole, ibuprofen, carbamazepine, caffeine, paracetamol, p-chlorobenzoic acid, fluoxetine) with different physicochemical properties and reaction rate constants with ozone and hydroxyl radicals was examined. More specifically, regarding the homogeneous catalytic ozonation process the catalytic action of 5 widely used transition metal ions (Co(II), Fe(II), Mn(II), Ni(II) και Zn(II)) was examined with the use of p-CBA as probe-compound and the mechanism by which these metal ions enhance or not the hydroxyl radicals production was evaluated. The optimum catalysts in deionized water were Co(II) and Fe(II), due to their ability of forming percipients/hydroxy-oxides from their oxidized forms. The positively charged hydroxy-oxides favor the adsorption of the negatively charged p-CBA, while their hydrophilicity improves ozone decomposition and the subsequent production of the hydroxyl radicals. The p-CBA removal increased with the increase of the pH value and ozone concentration, while the optimum temperature was the 25o C. Also, the catalytic action of Co(II) and Fe(II) against benzotriazole and carbamazepine was examined. The concentration of benzotriazole was under 3 μg/L at the 5 min of the oxidation reaction, while the concentration of carbamazepine was under 5.9 μg/L from the 1 min of the reaction even with the application of single ozonationThe study of p-CBA removal with the use of Co(II) and Fe(II) was extended to natural potable waster, where it appeared that only Fe(II) showed catalytic action, due to the precipitation of its trivalent form (Fe(OH)3). The Co(II) showed catalytic action only in the presence of phosphates, due to the formation of Co3(PO4)2 solids transforming homogeneous catalytic ozonation into a heterogeneous one, like in the case of iron. At low concentrations phosphates act as inhibitors, while at concentration higher than 10 mg/L the formation of Co3(PO4)2 enhanced the production of hydroxyl radicals. Although, the phosphate ions can transform Co(II) into a catalyst, their necessary presence in high concentrations transforms the treated water into a waste and further treatment is required before its deposition in the environment. Regarding, heterogeneous catalytic ozonation, the removal of p-CBA with the use of 18 different solid materials was studied in deionized water aiming the role of surface charge and wettability of the solid materials in the contact of ozone with the surface of the catalysts to be investigated and these parameters to be correlated with the enhancement of hydroxyl radicals production, as well as, with the final removal efficiency. This study showed that mainly the point of zero charge (PZC) and the wettability of the solid materials determine the relationship/interaction between ozone and their surface. Neutrally charged hydrophilic surfaces enhances ozone decomposition into hydroxyl radicals. The adsorption capacity of the solid materials does not correlate with the PZC value and although it seems that contributes in p-CBA removal, does not show any particular correlation with the catalytic action of the materials. The most efficient catalysts were: silica-alumina, alumina-504, alumina-507, SiO2, Bayoxide, zeolite, calcite and dolomite with which residual p-CBA concentrations lower than the analytical detection limit (3,9 μg/L) at the 15 min of the oxidation were achieved. In the contrary, the two studied carbons (Activated Carbon and MWCNTs) proved to be inappropriate materials for the ozonation process, due to their instability in the oxidative conditions of ozone. Also, from the 18 solid materials 3 were chosen and in particular: zeolite, talc and kaolin, in order the influence of the thermal treatment in their catalytic action to be examined. It turned out that the thermal treatment improves the catalytic action of the solid materials through the increase of their PZC value and wettability. Alongside, the action of the main Reactive Oxygen Species (ROS) in the removal of p-CBA from aqueous solutions using solid materials of different surface charge was studied. The p-CBA removal is based on the radical’s mechanism and this confirmed by the addition of TBA, p-benzoquinone and TEMP in the ozonation systems that significantly reduced its removal. From the experimental conditions study it was determined that the optimum conditions for the examined materials were pH 8 and temperature of 25o C, in which ozone dissolution in the aqueous phase was satisfactory, ozone decomposition rapid and hydroxyl radical’s production high. On the other hand, the catalyst dose is depended on the reaction kinetics. For fast rate reactions (pH 7 and 8, temperatures of 25o C and 35o C) the optimum dose was as low as possible, while at slow rate reactions (pH 6, temperature of 15o C) the optimum dose increases. The same applies and when different target compounds are used, because they determine the rate of the reaction. The optimum dose for the case of atrazine, which presents slow ozone decomposition kinetics, was 2.5 g/L of alumina-507.Ozone decomposition follows 1st order kinetic model independently of the ozonation system or the conditions of the reaction. On the other hand, the kinetic model of p-CBA degradation depends on the adding material. When, the solids that used in the ozonation system presents catalytic action, the p-CBA degradation follows the 2nd order kinetic model, while the pseudo-2nd order kinetic model is applied when the solid cannot be considered as a catalyst and in that case there is a removal limit, which in this thesis was 0.18 μM. Also, the efficiency of heterogeneous (catalysts: calcite) and homogeneous catalytic ozonation (Co(II), Fe(II)) in deionized water in the removal of benzotriazole, carbamazepine and p-CBA was evaluated. The objective of the study,besides the comparisonbetween the different processes, was the investigation of the participation rate of the mechanisms of ozone reactions (direct/indirect) according to the studied pollutant. By the comparison, calcite found to be the optimum catalyst, but the removal efficiency depends on the physicochemical properties of the pollutants. The p-CBA, which presents reaction rate constant with the hydroxyl radicals equals to 5x109 M-1s-1 removed efficiently during catalytic ozonation, due to the increase of hydroxyl radicals production by catalyst addition, while the oxidation of carbamazepine was based on the reactions with ozone. Benzotriazole reacted with both oxidative agents. Also, benzotriazole’s removal, in contrast to p-CBA presented higher correlation with the 1st order kinetic model. In the study that was conducted in natural potable water SiO2 and Al2O3 were used as catalysts. The aim of the study was the investigation of the catalytic action against 8 micropollutants with different physicochemical properties in systems with one pollutant or mixture of them and the evaluation of the influence of the catalyst in the removal of the organic compounds (chemical affinity). The studied micropollutants were: atrazine, benzotriazole, ibuprofen, carbamazepine, caffeine, paracetamol, p-CBA and fluoxetine. The concentration of carbamazepine, paracetamol and fluoxetine were under 5.9 μg/L, 1.2 μg/L και 15.5 μg/L from the 1 min of the reaction despite of the number of pollutants and the ozonation system. These three pollutants have high reaction rate constants with ozone and remove easily by the direct reactions. On the other hand, benzotriazole and caffeine are two moderate oxidizable compounds, of which the removal was enhanced by the addition of the catalysts in the ozonation system. Optimum catalyst was the silicon oxide. Regarding, the difficult oxidizing pollutants (atrazine, ibuprofen, p-CBA) both the solid materials presented catalytic action for ibuprofen and p-CBA, but the optimum was SiO2 and Al2O3 respectively. On the contrary, alumina cannot be considered as a catalyst for the removalof atrazine. Atrazine presents affinity only with the silicon and for that, it removed in higher extent by its presence. However, none of the three micropollutants when added to the ozonation system at a concentration of 500 μg/L were effectively removed and their concentrations after the application of catalytic ozonation were greater than 100 μg/L. In the mixture where the initial concentration of each compound was 50 μg/L, their residual concentration was under the detection limit of the analytical technique. During the 30 min of the oxidation process the concentration of p-CBA and atrazine was less than 3.1 μg/L and 5.4 μg/L using Al2O3 and SiO2 as catalysts respectively.

Degree

thesis:*
Grantor dc:publisher
Aristotle University Of Thessaloniki (AUTH)
Year dc:date
2021

Author and committee

dc:creator, dc:contributor.*
Authors dc:creator
  • Psaltou, Savvina
  • Ψάλτου, Σαββίνα

Subjects

dc:subject × 12

Rights

Language dc:language
gre

Identifiers

dc:identifier.*
Identifier
10.12681/eadd/51324

Chain of custody

source
Harvested from
Greek National Archive of PhD Theses
Base URL
phdtheses.ekt.gr/eadd_oai/request
Last updated
2026-11-18
Source record
OAI-PMH GetRecord
citation

Psaltou, Savvina; Ψάλτου, Σαββίνα. Απομάκρυνση μικρορύπων από επιρυπασμένα νερά με την εφαρμογή του καταλυτικού οζονισμού. Aristotle University Of Thessaloniki (AUTH), 2021. http://hdl.handle.net/10442/hedi/51324